Effects of gadolinium contrast agent on aortic blood flow and myocardial strain measurements by phase-contrast cardiovascular magnetic resonance

BACKGROUND: Quantitative blood flow and aspects of regional myocardial function such as myocardial displacement and strain can be measured using phase-contrast cardiovascular magnetic resonance (PC-CMR). Since a gadolinium-based contrast agent is often used to measure myocardial infarct size, we sou...

Descripción completa

Detalles Bibliográficos
Autores principales: Hedström, Erik, Bloch, Karin Markenroth, Bergvall, Erik, Ståhlberg, Freddy, Arheden, Håkan
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3002915/
https://www.ncbi.nlm.nih.gov/pubmed/21106081
http://dx.doi.org/10.1186/1532-429X-12-70
_version_ 1782193803287855104
author Hedström, Erik
Bloch, Karin Markenroth
Bergvall, Erik
Ståhlberg, Freddy
Arheden, Håkan
author_facet Hedström, Erik
Bloch, Karin Markenroth
Bergvall, Erik
Ståhlberg, Freddy
Arheden, Håkan
author_sort Hedström, Erik
collection PubMed
description BACKGROUND: Quantitative blood flow and aspects of regional myocardial function such as myocardial displacement and strain can be measured using phase-contrast cardiovascular magnetic resonance (PC-CMR). Since a gadolinium-based contrast agent is often used to measure myocardial infarct size, we sought to determine whether the contrast agent affects measurements of aortic flow and myocardial displacement and strain. Phase-contrast data pre and post contrast agent was acquired during free breathing using 1.5T PC-CMR. RESULTS: For aortic flow and regional myocardial function 12 and 17 patients were analysed, respectively. The difference pre and post contrast agent was 0.03 ± 0.16 l/min for cardiac output, and 0.1 ± 0.5 mm for myocardial displacement. Linear regression for myocardial displacement (MD) after and before contrast agent (CA) showed MD(postCA )= 0.95MD(preCA)+0.05 (r = 0.95, p < 0.001). For regional myocardial function, the contrast-to-noise ratios for left ventricular myocardial wall versus left ventricular lumen were pre and post contrast agent administration 7.4 ± 3.3 and 4.4 ± 8.9, respectively (p < 0.001). The contrast-to-noise ratios for left ventricular myocardial wall versus surrounding tissue were pre and post contrast agent administration -16.9 ± 22 and -0.2 ± 6.3, respectively (p < 0.0001). CONCLUSIONS: Quantitative measurements of aortic flow yield equal results both in the absence and presence of gadolinium contrast agent. The total examination time may thereby be reduced when assessing both viability and quantitative flow using PC-CMR, by assessing aortic flow post contrast agent administration. Phase-contrast information for myocardial displacement is also assessable both in the absence and presence of contrast agent. However, delineation of the myocardium may be difficult or impossible post contrast agent due to the lower image contrast. Acquisition of myocardial displacement should therefore be performed pre contrast agent using current PC-CMR sequences.
format Text
id pubmed-3002915
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-30029152010-12-17 Effects of gadolinium contrast agent on aortic blood flow and myocardial strain measurements by phase-contrast cardiovascular magnetic resonance Hedström, Erik Bloch, Karin Markenroth Bergvall, Erik Ståhlberg, Freddy Arheden, Håkan J Cardiovasc Magn Reson Research BACKGROUND: Quantitative blood flow and aspects of regional myocardial function such as myocardial displacement and strain can be measured using phase-contrast cardiovascular magnetic resonance (PC-CMR). Since a gadolinium-based contrast agent is often used to measure myocardial infarct size, we sought to determine whether the contrast agent affects measurements of aortic flow and myocardial displacement and strain. Phase-contrast data pre and post contrast agent was acquired during free breathing using 1.5T PC-CMR. RESULTS: For aortic flow and regional myocardial function 12 and 17 patients were analysed, respectively. The difference pre and post contrast agent was 0.03 ± 0.16 l/min for cardiac output, and 0.1 ± 0.5 mm for myocardial displacement. Linear regression for myocardial displacement (MD) after and before contrast agent (CA) showed MD(postCA )= 0.95MD(preCA)+0.05 (r = 0.95, p < 0.001). For regional myocardial function, the contrast-to-noise ratios for left ventricular myocardial wall versus left ventricular lumen were pre and post contrast agent administration 7.4 ± 3.3 and 4.4 ± 8.9, respectively (p < 0.001). The contrast-to-noise ratios for left ventricular myocardial wall versus surrounding tissue were pre and post contrast agent administration -16.9 ± 22 and -0.2 ± 6.3, respectively (p < 0.0001). CONCLUSIONS: Quantitative measurements of aortic flow yield equal results both in the absence and presence of gadolinium contrast agent. The total examination time may thereby be reduced when assessing both viability and quantitative flow using PC-CMR, by assessing aortic flow post contrast agent administration. Phase-contrast information for myocardial displacement is also assessable both in the absence and presence of contrast agent. However, delineation of the myocardium may be difficult or impossible post contrast agent due to the lower image contrast. Acquisition of myocardial displacement should therefore be performed pre contrast agent using current PC-CMR sequences. BioMed Central 2010-11-24 /pmc/articles/PMC3002915/ /pubmed/21106081 http://dx.doi.org/10.1186/1532-429X-12-70 Text en Copyright ©2010 Hedström et al; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (<url>http://creativecommons.org/licenses/by/2.0</url>), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Hedström, Erik
Bloch, Karin Markenroth
Bergvall, Erik
Ståhlberg, Freddy
Arheden, Håkan
Effects of gadolinium contrast agent on aortic blood flow and myocardial strain measurements by phase-contrast cardiovascular magnetic resonance
title Effects of gadolinium contrast agent on aortic blood flow and myocardial strain measurements by phase-contrast cardiovascular magnetic resonance
title_full Effects of gadolinium contrast agent on aortic blood flow and myocardial strain measurements by phase-contrast cardiovascular magnetic resonance
title_fullStr Effects of gadolinium contrast agent on aortic blood flow and myocardial strain measurements by phase-contrast cardiovascular magnetic resonance
title_full_unstemmed Effects of gadolinium contrast agent on aortic blood flow and myocardial strain measurements by phase-contrast cardiovascular magnetic resonance
title_short Effects of gadolinium contrast agent on aortic blood flow and myocardial strain measurements by phase-contrast cardiovascular magnetic resonance
title_sort effects of gadolinium contrast agent on aortic blood flow and myocardial strain measurements by phase-contrast cardiovascular magnetic resonance
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3002915/
https://www.ncbi.nlm.nih.gov/pubmed/21106081
http://dx.doi.org/10.1186/1532-429X-12-70
work_keys_str_mv AT hedstromerik effectsofgadoliniumcontrastagentonaorticbloodflowandmyocardialstrainmeasurementsbyphasecontrastcardiovascularmagneticresonance
AT blochkarinmarkenroth effectsofgadoliniumcontrastagentonaorticbloodflowandmyocardialstrainmeasurementsbyphasecontrastcardiovascularmagneticresonance
AT bergvallerik effectsofgadoliniumcontrastagentonaorticbloodflowandmyocardialstrainmeasurementsbyphasecontrastcardiovascularmagneticresonance
AT stahlbergfreddy effectsofgadoliniumcontrastagentonaorticbloodflowandmyocardialstrainmeasurementsbyphasecontrastcardiovascularmagneticresonance
AT arhedenhakan effectsofgadoliniumcontrastagentonaorticbloodflowandmyocardialstrainmeasurementsbyphasecontrastcardiovascularmagneticresonance