QA of intensity-modulated beams using dynamic MLC log files

To evaluate the utility of Dynalog file information for planar dose verification in IMRT QA, a program is developed to convert Dynalog file data to DMLC field files. For this study, five predefined fluencies are planned and delivered using Varian, Eclipse 3D planning system and 6MV photon beam of Va...

Descripción completa

Detalles Bibliográficos
Autores principales: Dinesh Kumar, M., Thirumavalavan, N., Venugopal Krishna, D., Babaiah, M.
Formato: Texto
Lenguaje:English
Publicado: Medknow Publications 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3003892/
https://www.ncbi.nlm.nih.gov/pubmed/21206638
http://dx.doi.org/10.4103/0971-6203.25668
_version_ 1782193922695495680
author Dinesh Kumar, M.
Thirumavalavan, N.
Venugopal Krishna, D.
Babaiah, M.
author_facet Dinesh Kumar, M.
Thirumavalavan, N.
Venugopal Krishna, D.
Babaiah, M.
author_sort Dinesh Kumar, M.
collection PubMed
description To evaluate the utility of Dynalog file information for planar dose verification in IMRT QA, a program is developed to convert Dynalog file data to DMLC field files. For this study, five predefined fluencies are planned and delivered using Varian, Eclipse 3D planning system and 6MV photon beam of Varian, Clinac DMX linear accelerator. To measure planar dose distribution, Kodak, EDR2 films are exposed in similar setup as planning setup. Dynalog files are recorded for each delivery and converted into DMLC field files using in-house program. Delivered dose distributions are calculated using DMLC field files from Dynalog files. Planned, Measured and Delivered dose distributions are compared using gamma evaluation in Scanditronix, Omni Pro IMRT software. The Planned and Delivered planar dose distributions agree within 2% dose difference and 2 mm DTA. Measured dose distributions agree within 4% dose difference and 4 mm DTA with Planned dose distribution. Our results show Dynalog file as a promising tool for dynamic IMRT QA.
format Text
id pubmed-3003892
institution National Center for Biotechnology Information
language English
publishDate 2006
publisher Medknow Publications
record_format MEDLINE/PubMed
spelling pubmed-30038922011-01-04 QA of intensity-modulated beams using dynamic MLC log files Dinesh Kumar, M. Thirumavalavan, N. Venugopal Krishna, D. Babaiah, M. J Med Phys Original Article To evaluate the utility of Dynalog file information for planar dose verification in IMRT QA, a program is developed to convert Dynalog file data to DMLC field files. For this study, five predefined fluencies are planned and delivered using Varian, Eclipse 3D planning system and 6MV photon beam of Varian, Clinac DMX linear accelerator. To measure planar dose distribution, Kodak, EDR2 films are exposed in similar setup as planning setup. Dynalog files are recorded for each delivery and converted into DMLC field files using in-house program. Delivered dose distributions are calculated using DMLC field files from Dynalog files. Planned, Measured and Delivered dose distributions are compared using gamma evaluation in Scanditronix, Omni Pro IMRT software. The Planned and Delivered planar dose distributions agree within 2% dose difference and 2 mm DTA. Measured dose distributions agree within 4% dose difference and 4 mm DTA with Planned dose distribution. Our results show Dynalog file as a promising tool for dynamic IMRT QA. Medknow Publications 2006 /pmc/articles/PMC3003892/ /pubmed/21206638 http://dx.doi.org/10.4103/0971-6203.25668 Text en © Journal of Medical Physics http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Dinesh Kumar, M.
Thirumavalavan, N.
Venugopal Krishna, D.
Babaiah, M.
QA of intensity-modulated beams using dynamic MLC log files
title QA of intensity-modulated beams using dynamic MLC log files
title_full QA of intensity-modulated beams using dynamic MLC log files
title_fullStr QA of intensity-modulated beams using dynamic MLC log files
title_full_unstemmed QA of intensity-modulated beams using dynamic MLC log files
title_short QA of intensity-modulated beams using dynamic MLC log files
title_sort qa of intensity-modulated beams using dynamic mlc log files
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3003892/
https://www.ncbi.nlm.nih.gov/pubmed/21206638
http://dx.doi.org/10.4103/0971-6203.25668
work_keys_str_mv AT dineshkumarm qaofintensitymodulatedbeamsusingdynamicmlclogfiles
AT thirumavalavann qaofintensitymodulatedbeamsusingdynamicmlclogfiles
AT venugopalkrishnad qaofintensitymodulatedbeamsusingdynamicmlclogfiles
AT babaiahm qaofintensitymodulatedbeamsusingdynamicmlclogfiles