Cargando…
QA of intensity-modulated beams using dynamic MLC log files
To evaluate the utility of Dynalog file information for planar dose verification in IMRT QA, a program is developed to convert Dynalog file data to DMLC field files. For this study, five predefined fluencies are planned and delivered using Varian, Eclipse 3D planning system and 6MV photon beam of Va...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications
2006
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3003892/ https://www.ncbi.nlm.nih.gov/pubmed/21206638 http://dx.doi.org/10.4103/0971-6203.25668 |
_version_ | 1782193922695495680 |
---|---|
author | Dinesh Kumar, M. Thirumavalavan, N. Venugopal Krishna, D. Babaiah, M. |
author_facet | Dinesh Kumar, M. Thirumavalavan, N. Venugopal Krishna, D. Babaiah, M. |
author_sort | Dinesh Kumar, M. |
collection | PubMed |
description | To evaluate the utility of Dynalog file information for planar dose verification in IMRT QA, a program is developed to convert Dynalog file data to DMLC field files. For this study, five predefined fluencies are planned and delivered using Varian, Eclipse 3D planning system and 6MV photon beam of Varian, Clinac DMX linear accelerator. To measure planar dose distribution, Kodak, EDR2 films are exposed in similar setup as planning setup. Dynalog files are recorded for each delivery and converted into DMLC field files using in-house program. Delivered dose distributions are calculated using DMLC field files from Dynalog files. Planned, Measured and Delivered dose distributions are compared using gamma evaluation in Scanditronix, Omni Pro IMRT software. The Planned and Delivered planar dose distributions agree within 2% dose difference and 2 mm DTA. Measured dose distributions agree within 4% dose difference and 4 mm DTA with Planned dose distribution. Our results show Dynalog file as a promising tool for dynamic IMRT QA. |
format | Text |
id | pubmed-3003892 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2006 |
publisher | Medknow Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-30038922011-01-04 QA of intensity-modulated beams using dynamic MLC log files Dinesh Kumar, M. Thirumavalavan, N. Venugopal Krishna, D. Babaiah, M. J Med Phys Original Article To evaluate the utility of Dynalog file information for planar dose verification in IMRT QA, a program is developed to convert Dynalog file data to DMLC field files. For this study, five predefined fluencies are planned and delivered using Varian, Eclipse 3D planning system and 6MV photon beam of Varian, Clinac DMX linear accelerator. To measure planar dose distribution, Kodak, EDR2 films are exposed in similar setup as planning setup. Dynalog files are recorded for each delivery and converted into DMLC field files using in-house program. Delivered dose distributions are calculated using DMLC field files from Dynalog files. Planned, Measured and Delivered dose distributions are compared using gamma evaluation in Scanditronix, Omni Pro IMRT software. The Planned and Delivered planar dose distributions agree within 2% dose difference and 2 mm DTA. Measured dose distributions agree within 4% dose difference and 4 mm DTA with Planned dose distribution. Our results show Dynalog file as a promising tool for dynamic IMRT QA. Medknow Publications 2006 /pmc/articles/PMC3003892/ /pubmed/21206638 http://dx.doi.org/10.4103/0971-6203.25668 Text en © Journal of Medical Physics http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Dinesh Kumar, M. Thirumavalavan, N. Venugopal Krishna, D. Babaiah, M. QA of intensity-modulated beams using dynamic MLC log files |
title | QA of intensity-modulated beams using dynamic MLC log files |
title_full | QA of intensity-modulated beams using dynamic MLC log files |
title_fullStr | QA of intensity-modulated beams using dynamic MLC log files |
title_full_unstemmed | QA of intensity-modulated beams using dynamic MLC log files |
title_short | QA of intensity-modulated beams using dynamic MLC log files |
title_sort | qa of intensity-modulated beams using dynamic mlc log files |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3003892/ https://www.ncbi.nlm.nih.gov/pubmed/21206638 http://dx.doi.org/10.4103/0971-6203.25668 |
work_keys_str_mv | AT dineshkumarm qaofintensitymodulatedbeamsusingdynamicmlclogfiles AT thirumavalavann qaofintensitymodulatedbeamsusingdynamicmlclogfiles AT venugopalkrishnad qaofintensitymodulatedbeamsusingdynamicmlclogfiles AT babaiahm qaofintensitymodulatedbeamsusingdynamicmlclogfiles |