Magnetic resonance imaging for adaptive cobalt tomotherapy: A proposal

Magnetic resonance imaging (MRI) provides excellent soft tissue contrast for oncology applications. We propose to combine a MRI scanner with a helical tomotherapy (HT) system to enable daily target imaging for improved conformal radiation dose delivery to a patient. HT uses an intensity-modulated fa...

Descripción completa

Detalles Bibliográficos
Autores principales: Kron, Tomas, Eyles, David, Schreiner, L John, Battista, Jerry
Formato: Texto
Lenguaje:English
Publicado: Medknow Publications 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3004099/
https://www.ncbi.nlm.nih.gov/pubmed/21206640
http://dx.doi.org/10.4103/0971-6203.29194
_version_ 1782193948927721472
author Kron, Tomas
Eyles, David
Schreiner, L John
Battista, Jerry
author_facet Kron, Tomas
Eyles, David
Schreiner, L John
Battista, Jerry
author_sort Kron, Tomas
collection PubMed
description Magnetic resonance imaging (MRI) provides excellent soft tissue contrast for oncology applications. We propose to combine a MRI scanner with a helical tomotherapy (HT) system to enable daily target imaging for improved conformal radiation dose delivery to a patient. HT uses an intensity-modulated fan-beam that revolves around a patient, while the patient slowly advances through the plane of rotation, yielding a helical beam trajectory. Since the use of a linear accelerator to produce radiation may be incompatible with the pulsed radiofrequency and the high and pulsed magnetic fields required for MRI, it is proposed that a radioactive Cobalt-60 ((60)Co) source be used instead to provide the radiation. An open low field (0.25 T) MRI system is proposed where the tomotherapy ring gantry is located between two sets of Helmholtz coils that can generate a sufficiently homogenous main magnetic field. It is shown that the two major challenges with the design, namely acceptable radiation dose rate (and therefore treatment duration) and moving parts in strong magnetic field, can be addressed. The high dose rate desired for helical tomotherapy delivery can be achieved using two radiation sources of 220TBq (6000Ci) each on a ring gantry with a source to axis-of-rotation distance of 75 cm. In addition to this, a dual row multi-leaf collimator (MLC) system with 15 mm leaf width at isocentre and relatively large fan beam widths between 15 and 30 mm per row shall be employed. In this configuration, the unit would be well-suited for most pelvic radiotherapy applications where the soft tissue contrast of MRI will be particularly beneficial. Non-magnetic MRI compatible materials must be used for the rotating gantry. Tungsten, which is non-magnetic, can be used for primary collimation of the fan-beam as well as for the MLC, which allows intensity modulated radiation delivery. We propose to employ a low magnetic Cobalt compound, sycoporite (CoS) for the Cobalt source material itself. Rotational delivery is less susceptible to problems related to the use of a low energy megavoltage photon source while the helical delivery reduces the negative impact of the relatively large penumbra inherent in the use of Cobalt sources for radiotherapy. On the other hand, the use of a (60)Co source ensures constant dose rate with gantry rotation and makes dose calculation in a magnetic field as easy as the range of secondary electrons is limited. The MR-integrated Cobalt tomotherapy unit, dubbed ‘MiCoTo,’ uses two independent physical principles for image acquisition and treatment delivery. It would offer excellent target definition and will allow following target motion during treatment using fast imaging techniques thus providing the best possible input for adaptive radiotherapy. As an additional bonus, quality assurance of the radiation delivery can be performed in situ using radiation sensitive gels imaged by MRI.
format Text
id pubmed-3004099
institution National Center for Biotechnology Information
language English
publishDate 2006
publisher Medknow Publications
record_format MEDLINE/PubMed
spelling pubmed-30040992011-01-04 Magnetic resonance imaging for adaptive cobalt tomotherapy: A proposal Kron, Tomas Eyles, David Schreiner, L John Battista, Jerry J Med Phys Original Article Magnetic resonance imaging (MRI) provides excellent soft tissue contrast for oncology applications. We propose to combine a MRI scanner with a helical tomotherapy (HT) system to enable daily target imaging for improved conformal radiation dose delivery to a patient. HT uses an intensity-modulated fan-beam that revolves around a patient, while the patient slowly advances through the plane of rotation, yielding a helical beam trajectory. Since the use of a linear accelerator to produce radiation may be incompatible with the pulsed radiofrequency and the high and pulsed magnetic fields required for MRI, it is proposed that a radioactive Cobalt-60 ((60)Co) source be used instead to provide the radiation. An open low field (0.25 T) MRI system is proposed where the tomotherapy ring gantry is located between two sets of Helmholtz coils that can generate a sufficiently homogenous main magnetic field. It is shown that the two major challenges with the design, namely acceptable radiation dose rate (and therefore treatment duration) and moving parts in strong magnetic field, can be addressed. The high dose rate desired for helical tomotherapy delivery can be achieved using two radiation sources of 220TBq (6000Ci) each on a ring gantry with a source to axis-of-rotation distance of 75 cm. In addition to this, a dual row multi-leaf collimator (MLC) system with 15 mm leaf width at isocentre and relatively large fan beam widths between 15 and 30 mm per row shall be employed. In this configuration, the unit would be well-suited for most pelvic radiotherapy applications where the soft tissue contrast of MRI will be particularly beneficial. Non-magnetic MRI compatible materials must be used for the rotating gantry. Tungsten, which is non-magnetic, can be used for primary collimation of the fan-beam as well as for the MLC, which allows intensity modulated radiation delivery. We propose to employ a low magnetic Cobalt compound, sycoporite (CoS) for the Cobalt source material itself. Rotational delivery is less susceptible to problems related to the use of a low energy megavoltage photon source while the helical delivery reduces the negative impact of the relatively large penumbra inherent in the use of Cobalt sources for radiotherapy. On the other hand, the use of a (60)Co source ensures constant dose rate with gantry rotation and makes dose calculation in a magnetic field as easy as the range of secondary electrons is limited. The MR-integrated Cobalt tomotherapy unit, dubbed ‘MiCoTo,’ uses two independent physical principles for image acquisition and treatment delivery. It would offer excellent target definition and will allow following target motion during treatment using fast imaging techniques thus providing the best possible input for adaptive radiotherapy. As an additional bonus, quality assurance of the radiation delivery can be performed in situ using radiation sensitive gels imaged by MRI. Medknow Publications 2006 /pmc/articles/PMC3004099/ /pubmed/21206640 http://dx.doi.org/10.4103/0971-6203.29194 Text en © Journal of Medical Physics http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kron, Tomas
Eyles, David
Schreiner, L John
Battista, Jerry
Magnetic resonance imaging for adaptive cobalt tomotherapy: A proposal
title Magnetic resonance imaging for adaptive cobalt tomotherapy: A proposal
title_full Magnetic resonance imaging for adaptive cobalt tomotherapy: A proposal
title_fullStr Magnetic resonance imaging for adaptive cobalt tomotherapy: A proposal
title_full_unstemmed Magnetic resonance imaging for adaptive cobalt tomotherapy: A proposal
title_short Magnetic resonance imaging for adaptive cobalt tomotherapy: A proposal
title_sort magnetic resonance imaging for adaptive cobalt tomotherapy: a proposal
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3004099/
https://www.ncbi.nlm.nih.gov/pubmed/21206640
http://dx.doi.org/10.4103/0971-6203.29194
work_keys_str_mv AT krontomas magneticresonanceimagingforadaptivecobalttomotherapyaproposal
AT eylesdavid magneticresonanceimagingforadaptivecobalttomotherapyaproposal
AT schreinerljohn magneticresonanceimagingforadaptivecobalttomotherapyaproposal
AT battistajerry magneticresonanceimagingforadaptivecobalttomotherapyaproposal