Cargando…
Objectively-assessed outcome measures: a translation and cross-cultural adaptation procedure applied to the Chedoke McMaster Arm and Hand Activity Inventory (CAHAI)
BACKGROUND: Standardised translation and cross-cultural adaptation (TCCA) procedures are vital to describe language translation, cultural adaptation, and to evaluate quality factors of transformed outcome measures. No TCCA procedure for objectively-assessed outcome (OAO) measures exists. Furthermore...
Autores principales: | , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3004924/ https://www.ncbi.nlm.nih.gov/pubmed/21114807 http://dx.doi.org/10.1186/1471-2288-10-106 |
_version_ | 1782194056292466688 |
---|---|
author | Schuster, Corina Hahn, Sabine Ettlin, Thierry |
author_facet | Schuster, Corina Hahn, Sabine Ettlin, Thierry |
author_sort | Schuster, Corina |
collection | PubMed |
description | BACKGROUND: Standardised translation and cross-cultural adaptation (TCCA) procedures are vital to describe language translation, cultural adaptation, and to evaluate quality factors of transformed outcome measures. No TCCA procedure for objectively-assessed outcome (OAO) measures exists. Furthermore, no official German version of the Canadian Chedoke Arm and Hand Activity Inventory (CAHAI) is available. METHODS: An eight-step for TCCA procedure for OAO was developed (TCCA-OAO) based on the existing TCCA procedure for patient-reported outcomes. The TCCA-OAO procedure was applied to develop a German version of the CAHAI (CAHAI-G). Inter-rater reliability of the CAHAI-G was determined through video rating of CAHAI-G. Validity evaluation of the CAHAI-G was assessed using the Chedoke-McMaster Stroke Assessment (CMSA). All ratings were performed by trained, independent raters. In a cross-sectional study, patients were tested within 31 hours after the initial CAHAI-G scoring, for their motor function level using the subscales for arm and hand of the CMSA. Inpatients and outpatients of the occupational therapy department who experienced a cerebrovascular accident or an intracerebral haemorrhage were included. RESULTS: Performance of 23 patients (mean age 69.4, SD 12.9; six females; mean time since stroke onset: 1.5 years, SD 2.5 years) have been assessed. A high inter-rater reliability was calculated with ICCs for 4 CAHAI-G versions (13, 9, 8, 7 items) ranging between r = 0.96 and r = 0.99 (p < 0.001). Correlation between the CAHAI-G and CMSA subscales for hand and arm was r = 0.74 (p < 0.001) and r = 0.67 (p < 0.001) respectively. Internal consistency of the CAHAI-G for all four versions ranged between α = 0.974 and α = 0.979. CONCLUSIONS: The TCCA-OAO procedure was validated regarding its feasibility and applicability for objectively-assessed outcome measures. The resulting German CAHAI can be used as a valid and reliable assessment for bilateral upper limb performance in ADL in patients after stroke. |
format | Text |
id | pubmed-3004924 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-30049242010-12-21 Objectively-assessed outcome measures: a translation and cross-cultural adaptation procedure applied to the Chedoke McMaster Arm and Hand Activity Inventory (CAHAI) Schuster, Corina Hahn, Sabine Ettlin, Thierry BMC Med Res Methodol Research Article BACKGROUND: Standardised translation and cross-cultural adaptation (TCCA) procedures are vital to describe language translation, cultural adaptation, and to evaluate quality factors of transformed outcome measures. No TCCA procedure for objectively-assessed outcome (OAO) measures exists. Furthermore, no official German version of the Canadian Chedoke Arm and Hand Activity Inventory (CAHAI) is available. METHODS: An eight-step for TCCA procedure for OAO was developed (TCCA-OAO) based on the existing TCCA procedure for patient-reported outcomes. The TCCA-OAO procedure was applied to develop a German version of the CAHAI (CAHAI-G). Inter-rater reliability of the CAHAI-G was determined through video rating of CAHAI-G. Validity evaluation of the CAHAI-G was assessed using the Chedoke-McMaster Stroke Assessment (CMSA). All ratings were performed by trained, independent raters. In a cross-sectional study, patients were tested within 31 hours after the initial CAHAI-G scoring, for their motor function level using the subscales for arm and hand of the CMSA. Inpatients and outpatients of the occupational therapy department who experienced a cerebrovascular accident or an intracerebral haemorrhage were included. RESULTS: Performance of 23 patients (mean age 69.4, SD 12.9; six females; mean time since stroke onset: 1.5 years, SD 2.5 years) have been assessed. A high inter-rater reliability was calculated with ICCs for 4 CAHAI-G versions (13, 9, 8, 7 items) ranging between r = 0.96 and r = 0.99 (p < 0.001). Correlation between the CAHAI-G and CMSA subscales for hand and arm was r = 0.74 (p < 0.001) and r = 0.67 (p < 0.001) respectively. Internal consistency of the CAHAI-G for all four versions ranged between α = 0.974 and α = 0.979. CONCLUSIONS: The TCCA-OAO procedure was validated regarding its feasibility and applicability for objectively-assessed outcome measures. The resulting German CAHAI can be used as a valid and reliable assessment for bilateral upper limb performance in ADL in patients after stroke. BioMed Central 2010-11-29 /pmc/articles/PMC3004924/ /pubmed/21114807 http://dx.doi.org/10.1186/1471-2288-10-106 Text en Copyright ©2010 Schuster et al; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (<url>http://creativecommons.org/licenses/by/2.0</url>), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Schuster, Corina Hahn, Sabine Ettlin, Thierry Objectively-assessed outcome measures: a translation and cross-cultural adaptation procedure applied to the Chedoke McMaster Arm and Hand Activity Inventory (CAHAI) |
title | Objectively-assessed outcome measures: a translation and cross-cultural adaptation procedure applied to the Chedoke McMaster Arm and Hand Activity Inventory (CAHAI) |
title_full | Objectively-assessed outcome measures: a translation and cross-cultural adaptation procedure applied to the Chedoke McMaster Arm and Hand Activity Inventory (CAHAI) |
title_fullStr | Objectively-assessed outcome measures: a translation and cross-cultural adaptation procedure applied to the Chedoke McMaster Arm and Hand Activity Inventory (CAHAI) |
title_full_unstemmed | Objectively-assessed outcome measures: a translation and cross-cultural adaptation procedure applied to the Chedoke McMaster Arm and Hand Activity Inventory (CAHAI) |
title_short | Objectively-assessed outcome measures: a translation and cross-cultural adaptation procedure applied to the Chedoke McMaster Arm and Hand Activity Inventory (CAHAI) |
title_sort | objectively-assessed outcome measures: a translation and cross-cultural adaptation procedure applied to the chedoke mcmaster arm and hand activity inventory (cahai) |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3004924/ https://www.ncbi.nlm.nih.gov/pubmed/21114807 http://dx.doi.org/10.1186/1471-2288-10-106 |
work_keys_str_mv | AT schustercorina objectivelyassessedoutcomemeasuresatranslationandcrossculturaladaptationprocedureappliedtothechedokemcmasterarmandhandactivityinventorycahai AT hahnsabine objectivelyassessedoutcomemeasuresatranslationandcrossculturaladaptationprocedureappliedtothechedokemcmasterarmandhandactivityinventorycahai AT ettlinthierry objectivelyassessedoutcomemeasuresatranslationandcrossculturaladaptationprocedureappliedtothechedokemcmasterarmandhandactivityinventorycahai |