Cargando…

Assessment of the abdominal wall function after pedicled TRAM flap surgery for breast reconstruction: Use of modified mesh repair for the donor defect

BACKGROUND: The pedicled TRAM flap has been a workhorse of autologous breast reconstruction for decades. However, there has been a rising concern about the abdominal wall donor site morbidity with the use of conventional TRAM flap. This has generally been cited as one of the main reasons for resorti...

Descripción completa

Detalles Bibliográficos
Autores principales: Cyriac, Chacko, Sharma, Ramesh Kumar, Singh, Gurpreet
Formato: Texto
Lenguaje:English
Publicado: Medknow Publication 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3010776/
https://www.ncbi.nlm.nih.gov/pubmed/21217974
http://dx.doi.org/10.4103/0970-0358.73430
_version_ 1782194839126802432
author Cyriac, Chacko
Sharma, Ramesh Kumar
Singh, Gurpreet
author_facet Cyriac, Chacko
Sharma, Ramesh Kumar
Singh, Gurpreet
author_sort Cyriac, Chacko
collection PubMed
description BACKGROUND: The pedicled TRAM flap has been a workhorse of autologous breast reconstruction for decades. However, there has been a rising concern about the abdominal wall donor site morbidity with the use of conventional TRAM flap. This has generally been cited as one of the main reasons for resorting to “abdominal wall friendly” techniques. This study has been undertaken to assess the abdominal wall function in patients with pedicled TRAM flap breast reconstruction. The entire width of the muscle and the overlying wide disk of anterior rectus sheath were harvested with the TRAM flap in all our patients and the anterior rectus sheath defect was repaired by a Proline mesh. MATERIALS AND METHODS: Abdominal wall function was studied in 21 patients who underwent simultaneous primary unipedicled TRAM flap reconstruction after mastectomy for cancer. In all the patients, the abdominal wall defect was repaired using wide sheet of Proline mesh both as inlay and onlay. The assessment tools included straight and rotational curl ups and a subjective questionnaire. The abdominal wall was also examined for any asymmetry, bulge, or hernia. The minimal follow-up was 6 months postoperative. The objective results were compared with normal unoperated volunteers. RESULTS AND CONCLUSIONS: The harvesting the TRAM flap certainly results in changes to the anterior abdominal wall that can express themselves to a variable degree. A relatively high incidence of asymptomatic asymmetry of the abdomen was seen. There was total absence of hernia in our series even after a mean follow-up period of 15.5 months. A few patients were only able to partially initiate the sit up movement and suffered an important loss of strength. In most patients, synergists took over the functional movement but as the load increased, flexion and rotation performances decreased. The lack of correlation between exercise tests and the results of the questionnaire suggests that this statistically significant impairment was functionally not important. The patients encountered little or no difficulty in theis day-to-day activities. Our modification of use of a wide mesh as inlay and onlay repair minimizes the donor site morbidity. This also avoids maneuvers meant for primary closure of the rectus sheath defects, which can result in distortion of umbilicus. Therefore, in conclusion, the unipedicled TRAM flap should be regarded as a valuable option in breast reconstruction provided careful repair of the abdominal wall defect is undertaken using Proline mesh.
format Text
id pubmed-3010776
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Medknow Publication
record_format MEDLINE/PubMed
spelling pubmed-30107762011-01-07 Assessment of the abdominal wall function after pedicled TRAM flap surgery for breast reconstruction: Use of modified mesh repair for the donor defect Cyriac, Chacko Sharma, Ramesh Kumar Singh, Gurpreet Indian J Plast Surg Original Article BACKGROUND: The pedicled TRAM flap has been a workhorse of autologous breast reconstruction for decades. However, there has been a rising concern about the abdominal wall donor site morbidity with the use of conventional TRAM flap. This has generally been cited as one of the main reasons for resorting to “abdominal wall friendly” techniques. This study has been undertaken to assess the abdominal wall function in patients with pedicled TRAM flap breast reconstruction. The entire width of the muscle and the overlying wide disk of anterior rectus sheath were harvested with the TRAM flap in all our patients and the anterior rectus sheath defect was repaired by a Proline mesh. MATERIALS AND METHODS: Abdominal wall function was studied in 21 patients who underwent simultaneous primary unipedicled TRAM flap reconstruction after mastectomy for cancer. In all the patients, the abdominal wall defect was repaired using wide sheet of Proline mesh both as inlay and onlay. The assessment tools included straight and rotational curl ups and a subjective questionnaire. The abdominal wall was also examined for any asymmetry, bulge, or hernia. The minimal follow-up was 6 months postoperative. The objective results were compared with normal unoperated volunteers. RESULTS AND CONCLUSIONS: The harvesting the TRAM flap certainly results in changes to the anterior abdominal wall that can express themselves to a variable degree. A relatively high incidence of asymptomatic asymmetry of the abdomen was seen. There was total absence of hernia in our series even after a mean follow-up period of 15.5 months. A few patients were only able to partially initiate the sit up movement and suffered an important loss of strength. In most patients, synergists took over the functional movement but as the load increased, flexion and rotation performances decreased. The lack of correlation between exercise tests and the results of the questionnaire suggests that this statistically significant impairment was functionally not important. The patients encountered little or no difficulty in theis day-to-day activities. Our modification of use of a wide mesh as inlay and onlay repair minimizes the donor site morbidity. This also avoids maneuvers meant for primary closure of the rectus sheath defects, which can result in distortion of umbilicus. Therefore, in conclusion, the unipedicled TRAM flap should be regarded as a valuable option in breast reconstruction provided careful repair of the abdominal wall defect is undertaken using Proline mesh. Medknow Publication 2010 /pmc/articles/PMC3010776/ /pubmed/21217974 http://dx.doi.org/10.4103/0970-0358.73430 Text en © Indian Journal of Plastic Surgery http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Cyriac, Chacko
Sharma, Ramesh Kumar
Singh, Gurpreet
Assessment of the abdominal wall function after pedicled TRAM flap surgery for breast reconstruction: Use of modified mesh repair for the donor defect
title Assessment of the abdominal wall function after pedicled TRAM flap surgery for breast reconstruction: Use of modified mesh repair for the donor defect
title_full Assessment of the abdominal wall function after pedicled TRAM flap surgery for breast reconstruction: Use of modified mesh repair for the donor defect
title_fullStr Assessment of the abdominal wall function after pedicled TRAM flap surgery for breast reconstruction: Use of modified mesh repair for the donor defect
title_full_unstemmed Assessment of the abdominal wall function after pedicled TRAM flap surgery for breast reconstruction: Use of modified mesh repair for the donor defect
title_short Assessment of the abdominal wall function after pedicled TRAM flap surgery for breast reconstruction: Use of modified mesh repair for the donor defect
title_sort assessment of the abdominal wall function after pedicled tram flap surgery for breast reconstruction: use of modified mesh repair for the donor defect
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3010776/
https://www.ncbi.nlm.nih.gov/pubmed/21217974
http://dx.doi.org/10.4103/0970-0358.73430
work_keys_str_mv AT cyriacchacko assessmentoftheabdominalwallfunctionafterpedicledtramflapsurgeryforbreastreconstructionuseofmodifiedmeshrepairforthedonordefect
AT sharmarameshkumar assessmentoftheabdominalwallfunctionafterpedicledtramflapsurgeryforbreastreconstructionuseofmodifiedmeshrepairforthedonordefect
AT singhgurpreet assessmentoftheabdominalwallfunctionafterpedicledtramflapsurgeryforbreastreconstructionuseofmodifiedmeshrepairforthedonordefect