Automated haematology analysis to diagnose malaria

For more than a decade, flow cytometry-based automated haematology analysers have been studied for malaria diagnosis. Although current haematology analysers are not specifically designed to detect malaria-related abnormalities, most studies have found sensitivities that comply with WHO malaria-diagn...

Descripción completa

Detalles Bibliográficos
Autores principales: Campuzano-Zuluaga, Germán, Hänscheid, Thomas, Grobusch, Martin P
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3013084/
https://www.ncbi.nlm.nih.gov/pubmed/21118557
http://dx.doi.org/10.1186/1475-2875-9-346
_version_ 1782195221825585152
author Campuzano-Zuluaga, Germán
Hänscheid, Thomas
Grobusch, Martin P
author_facet Campuzano-Zuluaga, Germán
Hänscheid, Thomas
Grobusch, Martin P
author_sort Campuzano-Zuluaga, Germán
collection PubMed
description For more than a decade, flow cytometry-based automated haematology analysers have been studied for malaria diagnosis. Although current haematology analysers are not specifically designed to detect malaria-related abnormalities, most studies have found sensitivities that comply with WHO malaria-diagnostic guidelines, i.e. ≥ 95% in samples with > 100 parasites/μl. Establishing a correct and early malaria diagnosis is a prerequisite for an adequate treatment and to minimizing adverse outcomes. Expert light microscopy remains the 'gold standard' for malaria diagnosis in most clinical settings. However, it requires an explicit request from clinicians and has variable accuracy. Malaria diagnosis with flow cytometry-based haematology analysers could become an important adjuvant diagnostic tool in the routine laboratory work-up of febrile patients in or returning from malaria-endemic regions. Haematology analysers so far studied for malaria diagnosis are the Cell-Dyn(®), Coulter(® )GEN·S and LH 750, and the Sysmex XE-2100(® )analysers. For Cell-Dyn analysers, abnormal depolarization events mainly in the lobularity/granularity and other scatter-plots, and various reticulocyte abnormalities have shown overall sensitivities and specificities of 49% to 97% and 61% to 100%, respectively. For the Coulter analysers, a 'malaria factor' using the monocyte and lymphocyte size standard deviations obtained by impedance detection has shown overall sensitivities and specificities of 82% to 98% and 72% to 94%, respectively. For the XE-2100, abnormal patterns in the DIFF, WBC/BASO, and RET-EXT scatter-plots, and pseudoeosinophilia and other abnormal haematological variables have been described, and multivariate diagnostic models have been designed with overall sensitivities and specificities of 86% to 97% and 81% to 98%, respectively. The accuracy for malaria diagnosis may vary according to species, parasite load, immunity and clinical context where the method is applied. Future developments in new haematology analysers such as considerably simplified, robust and inexpensive devices for malaria detection fitted with an automatically generated alert could improve the detection capacity of these instruments and potentially expand their clinical utility in malaria diagnosis.
format Text
id pubmed-3013084
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-30130842011-01-04 Automated haematology analysis to diagnose malaria Campuzano-Zuluaga, Germán Hänscheid, Thomas Grobusch, Martin P Malar J Review For more than a decade, flow cytometry-based automated haematology analysers have been studied for malaria diagnosis. Although current haematology analysers are not specifically designed to detect malaria-related abnormalities, most studies have found sensitivities that comply with WHO malaria-diagnostic guidelines, i.e. ≥ 95% in samples with > 100 parasites/μl. Establishing a correct and early malaria diagnosis is a prerequisite for an adequate treatment and to minimizing adverse outcomes. Expert light microscopy remains the 'gold standard' for malaria diagnosis in most clinical settings. However, it requires an explicit request from clinicians and has variable accuracy. Malaria diagnosis with flow cytometry-based haematology analysers could become an important adjuvant diagnostic tool in the routine laboratory work-up of febrile patients in or returning from malaria-endemic regions. Haematology analysers so far studied for malaria diagnosis are the Cell-Dyn(®), Coulter(® )GEN·S and LH 750, and the Sysmex XE-2100(® )analysers. For Cell-Dyn analysers, abnormal depolarization events mainly in the lobularity/granularity and other scatter-plots, and various reticulocyte abnormalities have shown overall sensitivities and specificities of 49% to 97% and 61% to 100%, respectively. For the Coulter analysers, a 'malaria factor' using the monocyte and lymphocyte size standard deviations obtained by impedance detection has shown overall sensitivities and specificities of 82% to 98% and 72% to 94%, respectively. For the XE-2100, abnormal patterns in the DIFF, WBC/BASO, and RET-EXT scatter-plots, and pseudoeosinophilia and other abnormal haematological variables have been described, and multivariate diagnostic models have been designed with overall sensitivities and specificities of 86% to 97% and 81% to 98%, respectively. The accuracy for malaria diagnosis may vary according to species, parasite load, immunity and clinical context where the method is applied. Future developments in new haematology analysers such as considerably simplified, robust and inexpensive devices for malaria detection fitted with an automatically generated alert could improve the detection capacity of these instruments and potentially expand their clinical utility in malaria diagnosis. BioMed Central 2010-11-30 /pmc/articles/PMC3013084/ /pubmed/21118557 http://dx.doi.org/10.1186/1475-2875-9-346 Text en Copyright ©2010 Campuzano-Zuluaga et al; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (<url>http://creativecommons.org/licenses/by/2.0</url>), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review
Campuzano-Zuluaga, Germán
Hänscheid, Thomas
Grobusch, Martin P
Automated haematology analysis to diagnose malaria
title Automated haematology analysis to diagnose malaria
title_full Automated haematology analysis to diagnose malaria
title_fullStr Automated haematology analysis to diagnose malaria
title_full_unstemmed Automated haematology analysis to diagnose malaria
title_short Automated haematology analysis to diagnose malaria
title_sort automated haematology analysis to diagnose malaria
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3013084/
https://www.ncbi.nlm.nih.gov/pubmed/21118557
http://dx.doi.org/10.1186/1475-2875-9-346
work_keys_str_mv AT campuzanozuluagagerman automatedhaematologyanalysistodiagnosemalaria
AT hanscheidthomas automatedhaematologyanalysistodiagnosemalaria
AT grobuschmartinp automatedhaematologyanalysistodiagnosemalaria