Cargando…

Multiscale Modeling of Light Absorption in Tissues: Limitations of Classical Homogenization Approach

In biophotonics, the light absorption in a tissue is usually modeled by the Helmholtz equation with two constant parameters, the scattering coefficient and the absorption coefficient. This classic approximation of “haemoglobin diluted everywhere” (constant absorption coefficient) corresponds to the...

Descripción completa

Detalles Bibliográficos
Autores principales: Mottin, Stephane, Panasenko, Grigory, Ganesh, S. Sivaji
Formato: Texto
Lenguaje:English
Publicado: Public Library of Science 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3013093/
https://www.ncbi.nlm.nih.gov/pubmed/21217816
http://dx.doi.org/10.1371/journal.pone.0014350
_version_ 1782195224824512512
author Mottin, Stephane
Panasenko, Grigory
Ganesh, S. Sivaji
author_facet Mottin, Stephane
Panasenko, Grigory
Ganesh, S. Sivaji
author_sort Mottin, Stephane
collection PubMed
description In biophotonics, the light absorption in a tissue is usually modeled by the Helmholtz equation with two constant parameters, the scattering coefficient and the absorption coefficient. This classic approximation of “haemoglobin diluted everywhere” (constant absorption coefficient) corresponds to the classical homogenization approach. The paper discusses the limitations of this approach. The scattering coefficient is supposed to be constant (equal to one) while the absorption coefficient is equal to zero everywhere except for a periodic set of thin parallel strips simulating the blood vessels, where it is a large parameter [Image: see text] The problem contains two other parameters which are small: [Image: see text], the ratio of the distance between the axes of vessels to the characteristic macroscopic size, and [Image: see text], the ratio of the thickness of thin vessels and the period. We construct asymptotic expansion in two cases: [Image: see text] and [Image: see text] and prove that in the first case the classical homogenization (averaging) of the differential equation is true while in the second case it is wrong. This result may be applied in the biomedical optics, for instance, in the modeling of the skin and cosmetics.
format Text
id pubmed-3013093
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-30130932011-01-07 Multiscale Modeling of Light Absorption in Tissues: Limitations of Classical Homogenization Approach Mottin, Stephane Panasenko, Grigory Ganesh, S. Sivaji PLoS One Research Article In biophotonics, the light absorption in a tissue is usually modeled by the Helmholtz equation with two constant parameters, the scattering coefficient and the absorption coefficient. This classic approximation of “haemoglobin diluted everywhere” (constant absorption coefficient) corresponds to the classical homogenization approach. The paper discusses the limitations of this approach. The scattering coefficient is supposed to be constant (equal to one) while the absorption coefficient is equal to zero everywhere except for a periodic set of thin parallel strips simulating the blood vessels, where it is a large parameter [Image: see text] The problem contains two other parameters which are small: [Image: see text], the ratio of the distance between the axes of vessels to the characteristic macroscopic size, and [Image: see text], the ratio of the thickness of thin vessels and the period. We construct asymptotic expansion in two cases: [Image: see text] and [Image: see text] and prove that in the first case the classical homogenization (averaging) of the differential equation is true while in the second case it is wrong. This result may be applied in the biomedical optics, for instance, in the modeling of the skin and cosmetics. Public Library of Science 2010-12-31 /pmc/articles/PMC3013093/ /pubmed/21217816 http://dx.doi.org/10.1371/journal.pone.0014350 Text en Mottin et al. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Mottin, Stephane
Panasenko, Grigory
Ganesh, S. Sivaji
Multiscale Modeling of Light Absorption in Tissues: Limitations of Classical Homogenization Approach
title Multiscale Modeling of Light Absorption in Tissues: Limitations of Classical Homogenization Approach
title_full Multiscale Modeling of Light Absorption in Tissues: Limitations of Classical Homogenization Approach
title_fullStr Multiscale Modeling of Light Absorption in Tissues: Limitations of Classical Homogenization Approach
title_full_unstemmed Multiscale Modeling of Light Absorption in Tissues: Limitations of Classical Homogenization Approach
title_short Multiscale Modeling of Light Absorption in Tissues: Limitations of Classical Homogenization Approach
title_sort multiscale modeling of light absorption in tissues: limitations of classical homogenization approach
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3013093/
https://www.ncbi.nlm.nih.gov/pubmed/21217816
http://dx.doi.org/10.1371/journal.pone.0014350
work_keys_str_mv AT mottinstephane multiscalemodelingoflightabsorptionintissueslimitationsofclassicalhomogenizationapproach
AT panasenkogrigory multiscalemodelingoflightabsorptionintissueslimitationsofclassicalhomogenizationapproach
AT ganeshssivaji multiscalemodelingoflightabsorptionintissueslimitationsofclassicalhomogenizationapproach