Cargando…
Multiscale Modeling of Light Absorption in Tissues: Limitations of Classical Homogenization Approach
In biophotonics, the light absorption in a tissue is usually modeled by the Helmholtz equation with two constant parameters, the scattering coefficient and the absorption coefficient. This classic approximation of “haemoglobin diluted everywhere” (constant absorption coefficient) corresponds to the...
Autores principales: | , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3013093/ https://www.ncbi.nlm.nih.gov/pubmed/21217816 http://dx.doi.org/10.1371/journal.pone.0014350 |
_version_ | 1782195224824512512 |
---|---|
author | Mottin, Stephane Panasenko, Grigory Ganesh, S. Sivaji |
author_facet | Mottin, Stephane Panasenko, Grigory Ganesh, S. Sivaji |
author_sort | Mottin, Stephane |
collection | PubMed |
description | In biophotonics, the light absorption in a tissue is usually modeled by the Helmholtz equation with two constant parameters, the scattering coefficient and the absorption coefficient. This classic approximation of “haemoglobin diluted everywhere” (constant absorption coefficient) corresponds to the classical homogenization approach. The paper discusses the limitations of this approach. The scattering coefficient is supposed to be constant (equal to one) while the absorption coefficient is equal to zero everywhere except for a periodic set of thin parallel strips simulating the blood vessels, where it is a large parameter [Image: see text] The problem contains two other parameters which are small: [Image: see text], the ratio of the distance between the axes of vessels to the characteristic macroscopic size, and [Image: see text], the ratio of the thickness of thin vessels and the period. We construct asymptotic expansion in two cases: [Image: see text] and [Image: see text] and prove that in the first case the classical homogenization (averaging) of the differential equation is true while in the second case it is wrong. This result may be applied in the biomedical optics, for instance, in the modeling of the skin and cosmetics. |
format | Text |
id | pubmed-3013093 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-30130932011-01-07 Multiscale Modeling of Light Absorption in Tissues: Limitations of Classical Homogenization Approach Mottin, Stephane Panasenko, Grigory Ganesh, S. Sivaji PLoS One Research Article In biophotonics, the light absorption in a tissue is usually modeled by the Helmholtz equation with two constant parameters, the scattering coefficient and the absorption coefficient. This classic approximation of “haemoglobin diluted everywhere” (constant absorption coefficient) corresponds to the classical homogenization approach. The paper discusses the limitations of this approach. The scattering coefficient is supposed to be constant (equal to one) while the absorption coefficient is equal to zero everywhere except for a periodic set of thin parallel strips simulating the blood vessels, where it is a large parameter [Image: see text] The problem contains two other parameters which are small: [Image: see text], the ratio of the distance between the axes of vessels to the characteristic macroscopic size, and [Image: see text], the ratio of the thickness of thin vessels and the period. We construct asymptotic expansion in two cases: [Image: see text] and [Image: see text] and prove that in the first case the classical homogenization (averaging) of the differential equation is true while in the second case it is wrong. This result may be applied in the biomedical optics, for instance, in the modeling of the skin and cosmetics. Public Library of Science 2010-12-31 /pmc/articles/PMC3013093/ /pubmed/21217816 http://dx.doi.org/10.1371/journal.pone.0014350 Text en Mottin et al. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Mottin, Stephane Panasenko, Grigory Ganesh, S. Sivaji Multiscale Modeling of Light Absorption in Tissues: Limitations of Classical Homogenization Approach |
title | Multiscale Modeling of Light Absorption in Tissues: Limitations of Classical Homogenization Approach |
title_full | Multiscale Modeling of Light Absorption in Tissues: Limitations of Classical Homogenization Approach |
title_fullStr | Multiscale Modeling of Light Absorption in Tissues: Limitations of Classical Homogenization Approach |
title_full_unstemmed | Multiscale Modeling of Light Absorption in Tissues: Limitations of Classical Homogenization Approach |
title_short | Multiscale Modeling of Light Absorption in Tissues: Limitations of Classical Homogenization Approach |
title_sort | multiscale modeling of light absorption in tissues: limitations of classical homogenization approach |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3013093/ https://www.ncbi.nlm.nih.gov/pubmed/21217816 http://dx.doi.org/10.1371/journal.pone.0014350 |
work_keys_str_mv | AT mottinstephane multiscalemodelingoflightabsorptionintissueslimitationsofclassicalhomogenizationapproach AT panasenkogrigory multiscalemodelingoflightabsorptionintissueslimitationsofclassicalhomogenizationapproach AT ganeshssivaji multiscalemodelingoflightabsorptionintissueslimitationsofclassicalhomogenizationapproach |