Cargando…
Efficacy of radial styloid targeting screws in volar plate fixation of intra-articular distal radial fractures: a biomechanical study in a cadaver fracture model
BACKGROUND: The locking screws target the radial styloid, theoretically provide greater stability against radial styloid fragment. However, it is unknown whether the radial styloid locking screws increased the stability of the volar plating system fixation along the entire distal radius or not. In t...
Autores principales: | , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3014894/ https://www.ncbi.nlm.nih.gov/pubmed/21122156 http://dx.doi.org/10.1186/1749-799X-5-90 |
_version_ | 1782195416025006080 |
---|---|
author | Iba, Kousuke Ozasa, Yasuhiro Wada, Takuro Kamiya, Tomoaki Yamashita, Toshihiko Aoki, Mitsuhiro |
author_facet | Iba, Kousuke Ozasa, Yasuhiro Wada, Takuro Kamiya, Tomoaki Yamashita, Toshihiko Aoki, Mitsuhiro |
author_sort | Iba, Kousuke |
collection | PubMed |
description | BACKGROUND: The locking screws target the radial styloid, theoretically provide greater stability against radial styloid fragment. However, it is unknown whether the radial styloid locking screws increased the stability of the volar plating system fixation along the entire distal radius or not. In this study, we evaluated the stability of the volar plating system fixation with or without the radial styloid screws using a biomechanical study in a cadaver fracture model. METHODS: Six matched pairs of fresh-frozen human cadaver wrists complete from the proximal forearm to the metacarpal bones were prepared to simulate standardized 3-part intra-articular and severe comminuted fractures. Specimens were fixed using the volar plating system with or without 2 radial styloid screws. Each specimen was loaded at a constant rate of 20 mm/min to failure. Load data was recorded and, ultimate strength and change in gap between distal and proximal fragments were measured. Data for ultimate strength and screw failure after failure loading were compared between the 2 groups. RESULTS: The average ultimate strength at failure of the volar plate fixation with radial styloid screws (913.5 ± 157.1 N) was significantly higher than that without them (682.2 ± 118.6 N). After failure loading, the average change in gap between the ulnar and proximal fragment was greater than that between the radial and proximal fragment. The number of bent or broken screws in ulnar fragment was higher than that in radial fragment. The number of specimens with bent or broken screws in cases with radial styloid screws was fewer than that in the fixation without radial styloid screws group. CONCLUSION: The ulnar fragment is more intensively stressed than the radial fragment under axial loading of distal radius at full wrist extension. The radial styloid screws were effective in stable volar plate fixation of distal radial fractures. |
format | Text |
id | pubmed-3014894 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-30148942011-01-05 Efficacy of radial styloid targeting screws in volar plate fixation of intra-articular distal radial fractures: a biomechanical study in a cadaver fracture model Iba, Kousuke Ozasa, Yasuhiro Wada, Takuro Kamiya, Tomoaki Yamashita, Toshihiko Aoki, Mitsuhiro J Orthop Surg Res Research Article BACKGROUND: The locking screws target the radial styloid, theoretically provide greater stability against radial styloid fragment. However, it is unknown whether the radial styloid locking screws increased the stability of the volar plating system fixation along the entire distal radius or not. In this study, we evaluated the stability of the volar plating system fixation with or without the radial styloid screws using a biomechanical study in a cadaver fracture model. METHODS: Six matched pairs of fresh-frozen human cadaver wrists complete from the proximal forearm to the metacarpal bones were prepared to simulate standardized 3-part intra-articular and severe comminuted fractures. Specimens were fixed using the volar plating system with or without 2 radial styloid screws. Each specimen was loaded at a constant rate of 20 mm/min to failure. Load data was recorded and, ultimate strength and change in gap between distal and proximal fragments were measured. Data for ultimate strength and screw failure after failure loading were compared between the 2 groups. RESULTS: The average ultimate strength at failure of the volar plate fixation with radial styloid screws (913.5 ± 157.1 N) was significantly higher than that without them (682.2 ± 118.6 N). After failure loading, the average change in gap between the ulnar and proximal fragment was greater than that between the radial and proximal fragment. The number of bent or broken screws in ulnar fragment was higher than that in radial fragment. The number of specimens with bent or broken screws in cases with radial styloid screws was fewer than that in the fixation without radial styloid screws group. CONCLUSION: The ulnar fragment is more intensively stressed than the radial fragment under axial loading of distal radius at full wrist extension. The radial styloid screws were effective in stable volar plate fixation of distal radial fractures. BioMed Central 2010-12-02 /pmc/articles/PMC3014894/ /pubmed/21122156 http://dx.doi.org/10.1186/1749-799X-5-90 Text en Copyright ©2010 Iba et al; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (<url>http://creativecommons.org/licenses/by/2.0</url>), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Iba, Kousuke Ozasa, Yasuhiro Wada, Takuro Kamiya, Tomoaki Yamashita, Toshihiko Aoki, Mitsuhiro Efficacy of radial styloid targeting screws in volar plate fixation of intra-articular distal radial fractures: a biomechanical study in a cadaver fracture model |
title | Efficacy of radial styloid targeting screws in volar plate fixation of intra-articular distal radial fractures: a biomechanical study in a cadaver fracture model |
title_full | Efficacy of radial styloid targeting screws in volar plate fixation of intra-articular distal radial fractures: a biomechanical study in a cadaver fracture model |
title_fullStr | Efficacy of radial styloid targeting screws in volar plate fixation of intra-articular distal radial fractures: a biomechanical study in a cadaver fracture model |
title_full_unstemmed | Efficacy of radial styloid targeting screws in volar plate fixation of intra-articular distal radial fractures: a biomechanical study in a cadaver fracture model |
title_short | Efficacy of radial styloid targeting screws in volar plate fixation of intra-articular distal radial fractures: a biomechanical study in a cadaver fracture model |
title_sort | efficacy of radial styloid targeting screws in volar plate fixation of intra-articular distal radial fractures: a biomechanical study in a cadaver fracture model |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3014894/ https://www.ncbi.nlm.nih.gov/pubmed/21122156 http://dx.doi.org/10.1186/1749-799X-5-90 |
work_keys_str_mv | AT ibakousuke efficacyofradialstyloidtargetingscrewsinvolarplatefixationofintraarticulardistalradialfracturesabiomechanicalstudyinacadaverfracturemodel AT ozasayasuhiro efficacyofradialstyloidtargetingscrewsinvolarplatefixationofintraarticulardistalradialfracturesabiomechanicalstudyinacadaverfracturemodel AT wadatakuro efficacyofradialstyloidtargetingscrewsinvolarplatefixationofintraarticulardistalradialfracturesabiomechanicalstudyinacadaverfracturemodel AT kamiyatomoaki efficacyofradialstyloidtargetingscrewsinvolarplatefixationofintraarticulardistalradialfracturesabiomechanicalstudyinacadaverfracturemodel AT yamashitatoshihiko efficacyofradialstyloidtargetingscrewsinvolarplatefixationofintraarticulardistalradialfracturesabiomechanicalstudyinacadaverfracturemodel AT aokimitsuhiro efficacyofradialstyloidtargetingscrewsinvolarplatefixationofintraarticulardistalradialfracturesabiomechanicalstudyinacadaverfracturemodel |