Testing the potential of a virtual reality neurorehabilitation system during performance of observation, imagery and imitation of motor actions recorded by wireless functional near-infrared spectroscopy (fNIRS)

BACKGROUND: Several neurorehabilitation strategies have been introduced over the last decade based on the so-called simulation hypothesis. This hypothesis states that a neural network located in primary and secondary motor areas is activated not only during overt motor execution, but also during obs...

Descripción completa

Detalles Bibliográficos
Autores principales: Holper, Lisa, Muehlemann, Thomas, Scholkmann, Felix, Eng, Kynan, Kiper, Daniel, Wolf, Martin
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3014953/
https://www.ncbi.nlm.nih.gov/pubmed/21122154
http://dx.doi.org/10.1186/1743-0003-7-57
_version_ 1782195432077656064
author Holper, Lisa
Muehlemann, Thomas
Scholkmann, Felix
Eng, Kynan
Kiper, Daniel
Wolf, Martin
author_facet Holper, Lisa
Muehlemann, Thomas
Scholkmann, Felix
Eng, Kynan
Kiper, Daniel
Wolf, Martin
author_sort Holper, Lisa
collection PubMed
description BACKGROUND: Several neurorehabilitation strategies have been introduced over the last decade based on the so-called simulation hypothesis. This hypothesis states that a neural network located in primary and secondary motor areas is activated not only during overt motor execution, but also during observation or imagery of the same motor action. Based on this hypothesis, we investigated the combination of a virtual reality (VR) based neurorehabilitation system together with a wireless functional near infrared spectroscopy (fNIRS) instrument. This combination is particularly appealing from a rehabilitation perspective as it may allow minimally constrained monitoring during neurorehabilitative training. METHODS: fNIRS was applied over F3 of healthy subjects during task performance in a virtual reality (VR) environment: 1) 'unilateral' group (N = 15), contralateral recording during observation, motor imagery, observation & motor imagery, and imitation of a grasping task performed by a virtual limb (first-person perspective view) using the right hand; 2) 'bilateral' group (N = 8), bilateral recording during observation and imitation of the same task using the right and left hand alternately. RESULTS: In the unilateral group, significant within-condition oxy-hemoglobin concentration Δ[O(2)Hb] changes (mean ± SD μmol/l) were found for motor imagery (0.0868 ± 0.5201 μmol/l) and imitation (0.1715 ± 0.4567 μmol/l). In addition, the bilateral group showed a significant within-condition Δ[O(2)Hb] change for observation (0.0924 ± 0.3369 μmol/l) as well as between-conditions with lower Δ[O(2)Hb] amplitudes during observation compared to imitation, especially in the ipsilateral hemisphere (p < 0.001). Further, in the bilateral group, imitation using the non-dominant (left) hand resulted in larger Δ[O(2)Hb] changes in both the ipsi- and contralateral hemispheres as compared to using the dominant (right) hand. CONCLUSIONS: This study shows that our combined VR-fNIRS based neurorehabilitation system can activate the action-observation system as described by the simulation hypothesis during performance of observation, motor imagery and imitation of hand actions elicited by a VR environment. Further, in accordance with previous studies, the findings of this study revealed that both inter-subject variability and handedness need to be taken into account when recording in untrained subjects. These findings are of relevance for demonstrating the potential of the VR-fNIRS instrument in neurofeedback applications.
format Text
id pubmed-3014953
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-30149532011-01-05 Testing the potential of a virtual reality neurorehabilitation system during performance of observation, imagery and imitation of motor actions recorded by wireless functional near-infrared spectroscopy (fNIRS) Holper, Lisa Muehlemann, Thomas Scholkmann, Felix Eng, Kynan Kiper, Daniel Wolf, Martin J Neuroeng Rehabil Research BACKGROUND: Several neurorehabilitation strategies have been introduced over the last decade based on the so-called simulation hypothesis. This hypothesis states that a neural network located in primary and secondary motor areas is activated not only during overt motor execution, but also during observation or imagery of the same motor action. Based on this hypothesis, we investigated the combination of a virtual reality (VR) based neurorehabilitation system together with a wireless functional near infrared spectroscopy (fNIRS) instrument. This combination is particularly appealing from a rehabilitation perspective as it may allow minimally constrained monitoring during neurorehabilitative training. METHODS: fNIRS was applied over F3 of healthy subjects during task performance in a virtual reality (VR) environment: 1) 'unilateral' group (N = 15), contralateral recording during observation, motor imagery, observation & motor imagery, and imitation of a grasping task performed by a virtual limb (first-person perspective view) using the right hand; 2) 'bilateral' group (N = 8), bilateral recording during observation and imitation of the same task using the right and left hand alternately. RESULTS: In the unilateral group, significant within-condition oxy-hemoglobin concentration Δ[O(2)Hb] changes (mean ± SD μmol/l) were found for motor imagery (0.0868 ± 0.5201 μmol/l) and imitation (0.1715 ± 0.4567 μmol/l). In addition, the bilateral group showed a significant within-condition Δ[O(2)Hb] change for observation (0.0924 ± 0.3369 μmol/l) as well as between-conditions with lower Δ[O(2)Hb] amplitudes during observation compared to imitation, especially in the ipsilateral hemisphere (p < 0.001). Further, in the bilateral group, imitation using the non-dominant (left) hand resulted in larger Δ[O(2)Hb] changes in both the ipsi- and contralateral hemispheres as compared to using the dominant (right) hand. CONCLUSIONS: This study shows that our combined VR-fNIRS based neurorehabilitation system can activate the action-observation system as described by the simulation hypothesis during performance of observation, motor imagery and imitation of hand actions elicited by a VR environment. Further, in accordance with previous studies, the findings of this study revealed that both inter-subject variability and handedness need to be taken into account when recording in untrained subjects. These findings are of relevance for demonstrating the potential of the VR-fNIRS instrument in neurofeedback applications. BioMed Central 2010-12-02 /pmc/articles/PMC3014953/ /pubmed/21122154 http://dx.doi.org/10.1186/1743-0003-7-57 Text en Copyright ©2010 Holper et al; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (<url>http://creativecommons.org/licenses/by/2.0</url>), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Holper, Lisa
Muehlemann, Thomas
Scholkmann, Felix
Eng, Kynan
Kiper, Daniel
Wolf, Martin
Testing the potential of a virtual reality neurorehabilitation system during performance of observation, imagery and imitation of motor actions recorded by wireless functional near-infrared spectroscopy (fNIRS)
title Testing the potential of a virtual reality neurorehabilitation system during performance of observation, imagery and imitation of motor actions recorded by wireless functional near-infrared spectroscopy (fNIRS)
title_full Testing the potential of a virtual reality neurorehabilitation system during performance of observation, imagery and imitation of motor actions recorded by wireless functional near-infrared spectroscopy (fNIRS)
title_fullStr Testing the potential of a virtual reality neurorehabilitation system during performance of observation, imagery and imitation of motor actions recorded by wireless functional near-infrared spectroscopy (fNIRS)
title_full_unstemmed Testing the potential of a virtual reality neurorehabilitation system during performance of observation, imagery and imitation of motor actions recorded by wireless functional near-infrared spectroscopy (fNIRS)
title_short Testing the potential of a virtual reality neurorehabilitation system during performance of observation, imagery and imitation of motor actions recorded by wireless functional near-infrared spectroscopy (fNIRS)
title_sort testing the potential of a virtual reality neurorehabilitation system during performance of observation, imagery and imitation of motor actions recorded by wireless functional near-infrared spectroscopy (fnirs)
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3014953/
https://www.ncbi.nlm.nih.gov/pubmed/21122154
http://dx.doi.org/10.1186/1743-0003-7-57
work_keys_str_mv AT holperlisa testingthepotentialofavirtualrealityneurorehabilitationsystemduringperformanceofobservationimageryandimitationofmotoractionsrecordedbywirelessfunctionalnearinfraredspectroscopyfnirs
AT muehlemannthomas testingthepotentialofavirtualrealityneurorehabilitationsystemduringperformanceofobservationimageryandimitationofmotoractionsrecordedbywirelessfunctionalnearinfraredspectroscopyfnirs
AT scholkmannfelix testingthepotentialofavirtualrealityneurorehabilitationsystemduringperformanceofobservationimageryandimitationofmotoractionsrecordedbywirelessfunctionalnearinfraredspectroscopyfnirs
AT engkynan testingthepotentialofavirtualrealityneurorehabilitationsystemduringperformanceofobservationimageryandimitationofmotoractionsrecordedbywirelessfunctionalnearinfraredspectroscopyfnirs
AT kiperdaniel testingthepotentialofavirtualrealityneurorehabilitationsystemduringperformanceofobservationimageryandimitationofmotoractionsrecordedbywirelessfunctionalnearinfraredspectroscopyfnirs
AT wolfmartin testingthepotentialofavirtualrealityneurorehabilitationsystemduringperformanceofobservationimageryandimitationofmotoractionsrecordedbywirelessfunctionalnearinfraredspectroscopyfnirs