Ventriculoperitoneal Shunt Failure as a Complication of Laparoscopic Surgery
OBJECTIVE: The authors report the first documented case of laparoscopically induced Ventriculoperitoneal (VP) shunt failure. SUMMARY BACKGROUND DATA: Laparoscopic surgery has become a preferred method of accessing and treating a variety of intraperitoneal pathology. Surgeons can expect to encounter...
Autores principales: | , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Society of Laparoendoscopic Surgeons
1998
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3015282/ https://www.ncbi.nlm.nih.gov/pubmed/9876734 |
_version_ | 1782195475555811328 |
---|---|
author | Baskin, Jonathan J. Vishteh, A. Giancarlo Wesche, Daniel E. Rekate, Harold L. Carrion, Carlos A. |
author_facet | Baskin, Jonathan J. Vishteh, A. Giancarlo Wesche, Daniel E. Rekate, Harold L. Carrion, Carlos A. |
author_sort | Baskin, Jonathan J. |
collection | PubMed |
description | OBJECTIVE: The authors report the first documented case of laparoscopically induced Ventriculoperitoneal (VP) shunt failure. SUMMARY BACKGROUND DATA: Laparoscopic surgery has become a preferred method of accessing and treating a variety of intraperitoneal pathology. Surgeons can expect to encounter patients who have previously under-gone placement of cerebrospinal fluid (CSF) shunts who present as candidates for laparoscopic procedures. Currently, the presence of a CSF shunt is not considered to be a contraindication to laparoscopy. We report the first documented case of laparoscopically induced VP shunt failure. CLINICAL HISTORY: A patient with shunt-dependent hydrocephalus underwent laparoscopic placement of a feeding jejunostomy. Postoperatively, clinical and radiographic evidence of shunt failure was noted. The patient under-went emergent shunt revision. Intraoperatively, an isolated distal shunt obstruction was encountered. Gentle irrigation cleared the occlusion. We believe that this shunt dysfunction was secondary to impaction of either soft tissue or air within the distal catheter as a consequence of peritoneal insufflation. CONCLUSIONS: It is concluded that laparoscopic surgery may represent a potential danger in patients with pre-existing CSF shunts. The risk of neurological injury faced by this patient population during laparoscopy is derived from peritoneal insufflation and relates to two primary concerns. The first is impaired CSF drainage due to a sustained elevated distal pressure gradient or, as in our case, an acute distal catheter obstruction. The second concern relates to the potential for retrograde insufflation of the CSF spaces through an incompetent shunt valve mechanism. Distal shunt catheter externalization performed in conjunction with a neurosurgeon during the laparoscopic procedure would prevent these complications. Internalization of the distal shunt catheter would then be performed at the completion of the laparoscopic procedure. |
format | Text |
id | pubmed-3015282 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1998 |
publisher | Society of Laparoendoscopic Surgeons |
record_format | MEDLINE/PubMed |
spelling | pubmed-30152822011-02-17 Ventriculoperitoneal Shunt Failure as a Complication of Laparoscopic Surgery Baskin, Jonathan J. Vishteh, A. Giancarlo Wesche, Daniel E. Rekate, Harold L. Carrion, Carlos A. JSLS Case Reports OBJECTIVE: The authors report the first documented case of laparoscopically induced Ventriculoperitoneal (VP) shunt failure. SUMMARY BACKGROUND DATA: Laparoscopic surgery has become a preferred method of accessing and treating a variety of intraperitoneal pathology. Surgeons can expect to encounter patients who have previously under-gone placement of cerebrospinal fluid (CSF) shunts who present as candidates for laparoscopic procedures. Currently, the presence of a CSF shunt is not considered to be a contraindication to laparoscopy. We report the first documented case of laparoscopically induced VP shunt failure. CLINICAL HISTORY: A patient with shunt-dependent hydrocephalus underwent laparoscopic placement of a feeding jejunostomy. Postoperatively, clinical and radiographic evidence of shunt failure was noted. The patient under-went emergent shunt revision. Intraoperatively, an isolated distal shunt obstruction was encountered. Gentle irrigation cleared the occlusion. We believe that this shunt dysfunction was secondary to impaction of either soft tissue or air within the distal catheter as a consequence of peritoneal insufflation. CONCLUSIONS: It is concluded that laparoscopic surgery may represent a potential danger in patients with pre-existing CSF shunts. The risk of neurological injury faced by this patient population during laparoscopy is derived from peritoneal insufflation and relates to two primary concerns. The first is impaired CSF drainage due to a sustained elevated distal pressure gradient or, as in our case, an acute distal catheter obstruction. The second concern relates to the potential for retrograde insufflation of the CSF spaces through an incompetent shunt valve mechanism. Distal shunt catheter externalization performed in conjunction with a neurosurgeon during the laparoscopic procedure would prevent these complications. Internalization of the distal shunt catheter would then be performed at the completion of the laparoscopic procedure. Society of Laparoendoscopic Surgeons 1998 /pmc/articles/PMC3015282/ /pubmed/9876734 Text en © 1998 by the Society of Laparoendoscopic Surgeons This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits for noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited and is not altered in any way. |
spellingShingle | Case Reports Baskin, Jonathan J. Vishteh, A. Giancarlo Wesche, Daniel E. Rekate, Harold L. Carrion, Carlos A. Ventriculoperitoneal Shunt Failure as a Complication of Laparoscopic Surgery |
title | Ventriculoperitoneal Shunt Failure as a Complication of Laparoscopic Surgery |
title_full | Ventriculoperitoneal Shunt Failure as a Complication of Laparoscopic Surgery |
title_fullStr | Ventriculoperitoneal Shunt Failure as a Complication of Laparoscopic Surgery |
title_full_unstemmed | Ventriculoperitoneal Shunt Failure as a Complication of Laparoscopic Surgery |
title_short | Ventriculoperitoneal Shunt Failure as a Complication of Laparoscopic Surgery |
title_sort | ventriculoperitoneal shunt failure as a complication of laparoscopic surgery |
topic | Case Reports |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3015282/ https://www.ncbi.nlm.nih.gov/pubmed/9876734 |
work_keys_str_mv | AT baskinjonathanj ventriculoperitonealshuntfailureasacomplicationoflaparoscopicsurgery AT vishtehagiancarlo ventriculoperitonealshuntfailureasacomplicationoflaparoscopicsurgery AT weschedaniele ventriculoperitonealshuntfailureasacomplicationoflaparoscopicsurgery AT rekateharoldl ventriculoperitonealshuntfailureasacomplicationoflaparoscopicsurgery AT carrioncarlosa ventriculoperitonealshuntfailureasacomplicationoflaparoscopicsurgery |