Cargando…

Suction Curettage for Removal of Retained Intrathoracic Blood Clots and Pleural Lesions

OBJECTIVE: To develop a thoracoscopic technique for correcting and/or removing an intrathoracic disease process using our existing operating room equipment and without a “small thoracotomy.” METHODS AND PROCEDURES: Fifty-eight patients from October 1994 to April 1998 were prospectively studied. All...

Descripción completa

Detalles Bibliográficos
Autores principales: Redan, Jay Alan, Palmer, Meade Todd, Tylutki, Francis John
Formato: Texto
Lenguaje:English
Publicado: Society of Laparoendoscopic Surgeons 1999
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3015315/
https://www.ncbi.nlm.nih.gov/pubmed/10444010
_version_ 1782195483318419456
author Redan, Jay Alan
Palmer, Meade Todd
Tylutki, Francis John
author_facet Redan, Jay Alan
Palmer, Meade Todd
Tylutki, Francis John
author_sort Redan, Jay Alan
collection PubMed
description OBJECTIVE: To develop a thoracoscopic technique for correcting and/or removing an intrathoracic disease process using our existing operating room equipment and without a “small thoracotomy.” METHODS AND PROCEDURES: Fifty-eight patients from October 1994 to April 1998 were prospectively studied. All were undergoing procedures involving the removal of a suspected benign (or infectious) pleural process or a retained blood clot. Three or four thoracic ports were used in all cases. Straight and curved suction curettage cannulae (with finger valve attachment) ranging from 8 to 16 French were available for use. Intermittent variable suction (between zero and 60 mm Hg) was used in all cases. Dependent upon the size and adherence of the lesion to be removed, the pressure was determined by the surgeon and regulated by the circulating nurse in the room. In each case, a trap system was used for retrieval of the specimen. One lung ventilation was used in every case, and when suction was used one of the ports was kept “open” to allow room air to enter the chest cavity. RESULTS: All patients in our series had their procedures completed without the need for any kind of open thoracotomy. Pre and postoperative diagnosis concurred in all 10 patients, and no complications occurred (specifically, no injury to the lung tissue or chest wall structures). Operative time ranged from 45 minutes to 180 minutes with a mean of 75 minutes. In all cases of a hemothorax, a cell saver system was used for an average of one unit of blood autotransfused per case. CONCLUSIONS: New techniques do not always require the purchase of new equipment. Tight hospital budgets are forcing surgeons to rely on redefining uses of instrumentation already available in solving surgical problems. We believe that the use of this instrumentation will provide another avenue for surgeons to successfully complete a procedure thoracoscopically without the need for a thoracotomy. It is through multidisciplinary conferences such as the Society of Laparoendoscopic Surgeons that ideas such as this are propagated.
format Text
id pubmed-3015315
institution National Center for Biotechnology Information
language English
publishDate 1999
publisher Society of Laparoendoscopic Surgeons
record_format MEDLINE/PubMed
spelling pubmed-30153152011-02-17 Suction Curettage for Removal of Retained Intrathoracic Blood Clots and Pleural Lesions Redan, Jay Alan Palmer, Meade Todd Tylutki, Francis John JSLS Scientific Papers OBJECTIVE: To develop a thoracoscopic technique for correcting and/or removing an intrathoracic disease process using our existing operating room equipment and without a “small thoracotomy.” METHODS AND PROCEDURES: Fifty-eight patients from October 1994 to April 1998 were prospectively studied. All were undergoing procedures involving the removal of a suspected benign (or infectious) pleural process or a retained blood clot. Three or four thoracic ports were used in all cases. Straight and curved suction curettage cannulae (with finger valve attachment) ranging from 8 to 16 French were available for use. Intermittent variable suction (between zero and 60 mm Hg) was used in all cases. Dependent upon the size and adherence of the lesion to be removed, the pressure was determined by the surgeon and regulated by the circulating nurse in the room. In each case, a trap system was used for retrieval of the specimen. One lung ventilation was used in every case, and when suction was used one of the ports was kept “open” to allow room air to enter the chest cavity. RESULTS: All patients in our series had their procedures completed without the need for any kind of open thoracotomy. Pre and postoperative diagnosis concurred in all 10 patients, and no complications occurred (specifically, no injury to the lung tissue or chest wall structures). Operative time ranged from 45 minutes to 180 minutes with a mean of 75 minutes. In all cases of a hemothorax, a cell saver system was used for an average of one unit of blood autotransfused per case. CONCLUSIONS: New techniques do not always require the purchase of new equipment. Tight hospital budgets are forcing surgeons to rely on redefining uses of instrumentation already available in solving surgical problems. We believe that the use of this instrumentation will provide another avenue for surgeons to successfully complete a procedure thoracoscopically without the need for a thoracotomy. It is through multidisciplinary conferences such as the Society of Laparoendoscopic Surgeons that ideas such as this are propagated. Society of Laparoendoscopic Surgeons 1999 /pmc/articles/PMC3015315/ /pubmed/10444010 Text en © 1999 by JSLS, Journal of the Society of Laparoendoscopic Surgeons. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits for noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited and is not altered in any way.
spellingShingle Scientific Papers
Redan, Jay Alan
Palmer, Meade Todd
Tylutki, Francis John
Suction Curettage for Removal of Retained Intrathoracic Blood Clots and Pleural Lesions
title Suction Curettage for Removal of Retained Intrathoracic Blood Clots and Pleural Lesions
title_full Suction Curettage for Removal of Retained Intrathoracic Blood Clots and Pleural Lesions
title_fullStr Suction Curettage for Removal of Retained Intrathoracic Blood Clots and Pleural Lesions
title_full_unstemmed Suction Curettage for Removal of Retained Intrathoracic Blood Clots and Pleural Lesions
title_short Suction Curettage for Removal of Retained Intrathoracic Blood Clots and Pleural Lesions
title_sort suction curettage for removal of retained intrathoracic blood clots and pleural lesions
topic Scientific Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3015315/
https://www.ncbi.nlm.nih.gov/pubmed/10444010
work_keys_str_mv AT redanjayalan suctioncurettageforremovalofretainedintrathoracicbloodclotsandpleurallesions
AT palmermeadetodd suctioncurettageforremovalofretainedintrathoracicbloodclotsandpleurallesions
AT tylutkifrancisjohn suctioncurettageforremovalofretainedintrathoracicbloodclotsandpleurallesions