Cargando…

Replacement of Expensive, Disposable Instruments With Old-fashioned Surgical Techniques for Improved Cost-effectiveness in Laparoscopic Hysterectomy

OBJECTIVE: Patients demand that health care and procedures in rural areas be provided by ambulatory surgery centers close to home. However, the reimbursement rate for such procedures in ambulatory centers is extremely low, so a standard classic intrafascial supracervical hysterectomy procedure needs...

Descripción completa

Detalles Bibliográficos
Autores principales: Morrison, John E., Jacobs, Volker R.
Formato: Texto
Lenguaje:English
Publicado: Society of Laparoendoscopic Surgeons 2004
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3015523/
https://www.ncbi.nlm.nih.gov/pubmed/15119671
_version_ 1782195535378120704
author Morrison, John E.
Jacobs, Volker R.
author_facet Morrison, John E.
Jacobs, Volker R.
author_sort Morrison, John E.
collection PubMed
description OBJECTIVE: Patients demand that health care and procedures in rural areas be provided by ambulatory surgery centers close to home. However, the reimbursement rate for such procedures in ambulatory centers is extremely low, so a standard classic intrafascial supracervical hysterectomy procedure needs to be more cost effective to be performed there. Instruments and disposable devices can make up ≥50% of hospital costs for this procedure, so any cost reduction has to focus on this aspect. METHODS: We identified the 3 most expensive disposable devices: (1) an Endostapler, US $498 and 3 staple reloads, US $179 each; (2) a calibrated uterine resection tool 15 mm for encoring of the endocervical canal, US $853; and (3) a serrated edged macro morcellator for intraabdominal uterus morcellation, US $321, and substituted them using classic conservative surgical techniques. RESULTS: From September 2001 to September 2002, we performed 26 procedures with this modified technique at an ambulatory surgery center with a follow-up of 6.7 (2 to 14) months. This modified operative technique was feasible; no conversions were necessary, and no complications occurred. Cost savings were US $2209 per procedure; additional costs were US $266.33 for suture material and an Endopouch, resulting in an overall savings of US $50 509.42. The disadvantage was an increase in operating room time of about 1 hour 20 minutes per case. CONCLUSION: These modifications in the classic intrafascial supracervical hysterectomy technique have proven to be feasible, safe, and highly cost effective, especially for a rural ambulatory surgery center. Long-term follow-up is necessary to further evaluate these operative modifications.
format Text
id pubmed-3015523
institution National Center for Biotechnology Information
language English
publishDate 2004
publisher Society of Laparoendoscopic Surgeons
record_format MEDLINE/PubMed
spelling pubmed-30155232011-02-17 Replacement of Expensive, Disposable Instruments With Old-fashioned Surgical Techniques for Improved Cost-effectiveness in Laparoscopic Hysterectomy Morrison, John E. Jacobs, Volker R. JSLS Case Reports OBJECTIVE: Patients demand that health care and procedures in rural areas be provided by ambulatory surgery centers close to home. However, the reimbursement rate for such procedures in ambulatory centers is extremely low, so a standard classic intrafascial supracervical hysterectomy procedure needs to be more cost effective to be performed there. Instruments and disposable devices can make up ≥50% of hospital costs for this procedure, so any cost reduction has to focus on this aspect. METHODS: We identified the 3 most expensive disposable devices: (1) an Endostapler, US $498 and 3 staple reloads, US $179 each; (2) a calibrated uterine resection tool 15 mm for encoring of the endocervical canal, US $853; and (3) a serrated edged macro morcellator for intraabdominal uterus morcellation, US $321, and substituted them using classic conservative surgical techniques. RESULTS: From September 2001 to September 2002, we performed 26 procedures with this modified technique at an ambulatory surgery center with a follow-up of 6.7 (2 to 14) months. This modified operative technique was feasible; no conversions were necessary, and no complications occurred. Cost savings were US $2209 per procedure; additional costs were US $266.33 for suture material and an Endopouch, resulting in an overall savings of US $50 509.42. The disadvantage was an increase in operating room time of about 1 hour 20 minutes per case. CONCLUSION: These modifications in the classic intrafascial supracervical hysterectomy technique have proven to be feasible, safe, and highly cost effective, especially for a rural ambulatory surgery center. Long-term follow-up is necessary to further evaluate these operative modifications. Society of Laparoendoscopic Surgeons 2004 /pmc/articles/PMC3015523/ /pubmed/15119671 Text en © 2004 by JSLS, Journal of the Society of Laparoendoscopic Surgeons This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits for noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited and is not altered in any way.
spellingShingle Case Reports
Morrison, John E.
Jacobs, Volker R.
Replacement of Expensive, Disposable Instruments With Old-fashioned Surgical Techniques for Improved Cost-effectiveness in Laparoscopic Hysterectomy
title Replacement of Expensive, Disposable Instruments With Old-fashioned Surgical Techniques for Improved Cost-effectiveness in Laparoscopic Hysterectomy
title_full Replacement of Expensive, Disposable Instruments With Old-fashioned Surgical Techniques for Improved Cost-effectiveness in Laparoscopic Hysterectomy
title_fullStr Replacement of Expensive, Disposable Instruments With Old-fashioned Surgical Techniques for Improved Cost-effectiveness in Laparoscopic Hysterectomy
title_full_unstemmed Replacement of Expensive, Disposable Instruments With Old-fashioned Surgical Techniques for Improved Cost-effectiveness in Laparoscopic Hysterectomy
title_short Replacement of Expensive, Disposable Instruments With Old-fashioned Surgical Techniques for Improved Cost-effectiveness in Laparoscopic Hysterectomy
title_sort replacement of expensive, disposable instruments with old-fashioned surgical techniques for improved cost-effectiveness in laparoscopic hysterectomy
topic Case Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3015523/
https://www.ncbi.nlm.nih.gov/pubmed/15119671
work_keys_str_mv AT morrisonjohne replacementofexpensivedisposableinstrumentswitholdfashionedsurgicaltechniquesforimprovedcosteffectivenessinlaparoscopichysterectomy
AT jacobsvolkerr replacementofexpensivedisposableinstrumentswitholdfashionedsurgicaltechniquesforimprovedcosteffectivenessinlaparoscopichysterectomy