Heated, Humidified CO(2) Gas Is Unsatisfactory for Awake Laparoscopy

BACKGROUND: The necessity for general anesthesia represents an impediment to using a laparoscopic approach for some procedures that are otherwise performed with the patient under local anesthesia using a conventional open technique. Heating and humidifying the insufflation gas reportedly reduces per...

Descripción completa

Detalles Bibliográficos
Autor principal: Crabtree, John H.
Formato: Texto
Lenguaje:English
Publicado: Society of Laparoendoscopic Surgeons 2005
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3015653/
https://www.ncbi.nlm.nih.gov/pubmed/16381368
Descripción
Sumario:BACKGROUND: The necessity for general anesthesia represents an impediment to using a laparoscopic approach for some procedures that are otherwise performed with the patient under local anesthesia using a conventional open technique. Heating and humidifying the insufflation gas reportedly reduces perioperative pain associated with a CO(2) pneumoperitoneum, thus enabling awake laparoscopy. METHODS: Two cases are reported herein of laparoscopy performed with the patient under local anesthesia using heated, humidified CO(2) gas for the pneumoperitoneum. RESULTS: Both patients experienced pain with insufflation of heated, humidified CO(2) gas of sufficient magnitude that the procedure could not be performed. The CO(2) gas was washed out and replaced with helium gas insufflation with complete resolution of pain. The laparoscopic procedures were accomplished without further discomfort with local anesthesia and using a helium gas pneumoperitoneum. CONCLUSIONS: Heated, humidified CO(2) gas insufflation does not reduce pain sufficiently to permit satisfactory performance of laparoscopy with local anesthesia, especially when full volume insufflation is required. Cold, dry helium gas produces no pain. The theory that cold, dry insufflation gas is a source of peritoneal pain during laparoscopy needs to be reassessed.