Rupture of the Spleen With the Harmonic Scalpel: Case Report of an Unexplained Complication
A 69-year-old female patient underwent a standard laparoscopic Nissen fundoplication for repair of a hiatal hernia and correction of reflux. A Harmonic scalpel was used as the only energy source intraoperatively. The operation was uneventful until the middle of the procedure when a significant amoun...
Autores principales: | , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Society of Laparoendoscopic Surgeons
2007
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3015727/ https://www.ncbi.nlm.nih.gov/pubmed/17761096 |
_version_ | 1782195588827185152 |
---|---|
author | Morrison, John E. Jacobs, Volker R. |
author_facet | Morrison, John E. Jacobs, Volker R. |
author_sort | Morrison, John E. |
collection | PubMed |
description | A 69-year-old female patient underwent a standard laparoscopic Nissen fundoplication for repair of a hiatal hernia and correction of reflux. A Harmonic scalpel was used as the only energy source intraoperatively. The operation was uneventful until the middle of the procedure when a significant amount of blood was noted in the left upper quadrant. After aspiration and careful inspection, a 5-cm irregular vertical laceration was found on the posterior and lateral aspect of the spleen, far away from the operative field and any previous instrumentation. Control of bleeding from the spleen was unsuccessful, so a laparoscopic splenectomy was performed, and the procedure was finished without further incident. Histologic examination revealed a normal spleen with no pathologic alterations accounting for the laceration. After comprehensive evaluation of this case to assess a potential cause of the complication, the question arose as to whether the energy produced by the Harmonic scalpel could have caused this splenic laceration. |
format | Text |
id | pubmed-3015727 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2007 |
publisher | Society of Laparoendoscopic Surgeons |
record_format | MEDLINE/PubMed |
spelling | pubmed-30157272011-02-17 Rupture of the Spleen With the Harmonic Scalpel: Case Report of an Unexplained Complication Morrison, John E. Jacobs, Volker R. JSLS Case Reports A 69-year-old female patient underwent a standard laparoscopic Nissen fundoplication for repair of a hiatal hernia and correction of reflux. A Harmonic scalpel was used as the only energy source intraoperatively. The operation was uneventful until the middle of the procedure when a significant amount of blood was noted in the left upper quadrant. After aspiration and careful inspection, a 5-cm irregular vertical laceration was found on the posterior and lateral aspect of the spleen, far away from the operative field and any previous instrumentation. Control of bleeding from the spleen was unsuccessful, so a laparoscopic splenectomy was performed, and the procedure was finished without further incident. Histologic examination revealed a normal spleen with no pathologic alterations accounting for the laceration. After comprehensive evaluation of this case to assess a potential cause of the complication, the question arose as to whether the energy produced by the Harmonic scalpel could have caused this splenic laceration. Society of Laparoendoscopic Surgeons 2007 /pmc/articles/PMC3015727/ /pubmed/17761096 Text en © 2007 by JSLS, Journal of the Society of Laparoendoscopic Surgeons. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits for noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited and is not altered in any way. |
spellingShingle | Case Reports Morrison, John E. Jacobs, Volker R. Rupture of the Spleen With the Harmonic Scalpel: Case Report of an Unexplained Complication |
title | Rupture of the Spleen With the Harmonic Scalpel: Case Report of an Unexplained Complication |
title_full | Rupture of the Spleen With the Harmonic Scalpel: Case Report of an Unexplained Complication |
title_fullStr | Rupture of the Spleen With the Harmonic Scalpel: Case Report of an Unexplained Complication |
title_full_unstemmed | Rupture of the Spleen With the Harmonic Scalpel: Case Report of an Unexplained Complication |
title_short | Rupture of the Spleen With the Harmonic Scalpel: Case Report of an Unexplained Complication |
title_sort | rupture of the spleen with the harmonic scalpel: case report of an unexplained complication |
topic | Case Reports |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3015727/ https://www.ncbi.nlm.nih.gov/pubmed/17761096 |
work_keys_str_mv | AT morrisonjohne ruptureofthespleenwiththeharmonicscalpelcasereportofanunexplainedcomplication AT jacobsvolkerr ruptureofthespleenwiththeharmonicscalpelcasereportofanunexplainedcomplication |