Cargando…

Strength of Tissue Attachment to Composite and ePTFE Grafts After Ventral Hernia Repair

OBJECTIVES: We sought to measure the strength of tissue attachment to mesh after laparoscopic ventral hernia repair in a porcine model. METHODS: Twelve swine had two 10-cm × 16-cm sheets of ePTFE and polypropylene/ePTFE composite mesh fixated to the abdominal wall laparoscopically. Animals were euth...

Descripción completa

Detalles Bibliográficos
Autores principales: Iannitti, David A., Hope, William W., Tsikitis, Vassiliki
Formato: Texto
Lenguaje:English
Publicado: Society of Laparoendoscopic Surgeons 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3015842/
https://www.ncbi.nlm.nih.gov/pubmed/18237503
_version_ 1782195618195701760
author Iannitti, David A.
Hope, William W.
Tsikitis, Vassiliki
author_facet Iannitti, David A.
Hope, William W.
Tsikitis, Vassiliki
author_sort Iannitti, David A.
collection PubMed
description OBJECTIVES: We sought to measure the strength of tissue attachment to mesh after laparoscopic ventral hernia repair in a porcine model. METHODS: Twelve swine had two 10-cm × 16-cm sheets of ePTFE and polypropylene/ePTFE composite mesh fixated to the abdominal wall laparoscopically. Animals were euthanized at 2, 4, 6, and 12 weeks. The strength of tissue ingrowth was measured using a lap-shear method. Data are reported as mean force in pounds. RESULTS: Average surface area of adhesions to percentage of surface area was not statistically significant between the composite and ePTFE materials. For the composite material, there was a 98.7% posterior probability that the force required at 2 weeks was less than that required at 12 weeks. There was no difference in graft-abdominal wall interface strength between week 2 and week 12 for ePTFE material. Both prosthetics achieved the majority of their strength from tissue ingrowth by 2 weeks, but the composite prosthesis continued to gain strength while the strength of the ePTFE plateaued. Composite mesh demonstrated a statistically significant increase in strength between the lap-shear force, whereas no statistically significant difference occurred in the ePTFE graft. For the composite material, there was complete cellular infiltration through the entire thickness of polypropylene (approximately 500 μm) to the ePTFE layer at 2 weeks. At 2 weeks for ePTFE, the cells did not penetrate into the graft on the visceral side. On the abdominal wall side, the grooves filled with tissue, but no cellular penetration into the ePTFE occurred. No histological difference existed in cellularity. CONCLUSION: This study demonstrates that the strength of tissue ingrowth is significantly higher (P<0.05) for the composite grafts relative to the ePTFE grafts at each time point. Approximately 74% of tissue ingrowth and strength occurs by 2 weeks postoperatively for the composite pros-thesis. The ePTFE graft tissue strength peaked and plateaued by 2 weeks. This may have clinical implications for human ventral hernia repair by partly addressing the issue of graft fixation to the abdominal wall during laparoscopic ventral hernia repair.
format Text
id pubmed-3015842
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher Society of Laparoendoscopic Surgeons
record_format MEDLINE/PubMed
spelling pubmed-30158422011-02-17 Strength of Tissue Attachment to Composite and ePTFE Grafts After Ventral Hernia Repair Iannitti, David A. Hope, William W. Tsikitis, Vassiliki JSLS Scientific Papers OBJECTIVES: We sought to measure the strength of tissue attachment to mesh after laparoscopic ventral hernia repair in a porcine model. METHODS: Twelve swine had two 10-cm × 16-cm sheets of ePTFE and polypropylene/ePTFE composite mesh fixated to the abdominal wall laparoscopically. Animals were euthanized at 2, 4, 6, and 12 weeks. The strength of tissue ingrowth was measured using a lap-shear method. Data are reported as mean force in pounds. RESULTS: Average surface area of adhesions to percentage of surface area was not statistically significant between the composite and ePTFE materials. For the composite material, there was a 98.7% posterior probability that the force required at 2 weeks was less than that required at 12 weeks. There was no difference in graft-abdominal wall interface strength between week 2 and week 12 for ePTFE material. Both prosthetics achieved the majority of their strength from tissue ingrowth by 2 weeks, but the composite prosthesis continued to gain strength while the strength of the ePTFE plateaued. Composite mesh demonstrated a statistically significant increase in strength between the lap-shear force, whereas no statistically significant difference occurred in the ePTFE graft. For the composite material, there was complete cellular infiltration through the entire thickness of polypropylene (approximately 500 μm) to the ePTFE layer at 2 weeks. At 2 weeks for ePTFE, the cells did not penetrate into the graft on the visceral side. On the abdominal wall side, the grooves filled with tissue, but no cellular penetration into the ePTFE occurred. No histological difference existed in cellularity. CONCLUSION: This study demonstrates that the strength of tissue ingrowth is significantly higher (P<0.05) for the composite grafts relative to the ePTFE grafts at each time point. Approximately 74% of tissue ingrowth and strength occurs by 2 weeks postoperatively for the composite pros-thesis. The ePTFE graft tissue strength peaked and plateaued by 2 weeks. This may have clinical implications for human ventral hernia repair by partly addressing the issue of graft fixation to the abdominal wall during laparoscopic ventral hernia repair. Society of Laparoendoscopic Surgeons 2007 /pmc/articles/PMC3015842/ /pubmed/18237503 Text en © 2007 by JSLS, Journal of the Society of Laparoendoscopic Surgeons. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits for noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited and is not altered in any way.
spellingShingle Scientific Papers
Iannitti, David A.
Hope, William W.
Tsikitis, Vassiliki
Strength of Tissue Attachment to Composite and ePTFE Grafts After Ventral Hernia Repair
title Strength of Tissue Attachment to Composite and ePTFE Grafts After Ventral Hernia Repair
title_full Strength of Tissue Attachment to Composite and ePTFE Grafts After Ventral Hernia Repair
title_fullStr Strength of Tissue Attachment to Composite and ePTFE Grafts After Ventral Hernia Repair
title_full_unstemmed Strength of Tissue Attachment to Composite and ePTFE Grafts After Ventral Hernia Repair
title_short Strength of Tissue Attachment to Composite and ePTFE Grafts After Ventral Hernia Repair
title_sort strength of tissue attachment to composite and eptfe grafts after ventral hernia repair
topic Scientific Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3015842/
https://www.ncbi.nlm.nih.gov/pubmed/18237503
work_keys_str_mv AT iannittidavida strengthoftissueattachmenttocompositeandeptfegraftsafterventralherniarepair
AT hopewilliamw strengthoftissueattachmenttocompositeandeptfegraftsafterventralherniarepair
AT tsikitisvassiliki strengthoftissueattachmenttocompositeandeptfegraftsafterventralherniarepair