Cargando…
Transabdominal Preperitoneal Herniorrhaphy using Laser-Assisted Tissue Soldering in a Porcine Model
BACKGROUND AND OBJECTIVES: Collagen solder is capable of fixation of surgical meshes during laparoscopic herniorrhaphy without compromising tissue integration, increasing adhesions or inflammation. This pilot study describes development of instrumentation and techniques for transabdominal preperiton...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Society of Laparoendoscopic Surgeons
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3015923/ https://www.ncbi.nlm.nih.gov/pubmed/19660214 |
_version_ | 1782195640680316928 |
---|---|
author | Lanzafame, Raymond J. Soltz, Barbara A. Stadler, Istvan Soltz, Robert |
author_facet | Lanzafame, Raymond J. Soltz, Barbara A. Stadler, Istvan Soltz, Robert |
author_sort | Lanzafame, Raymond J. |
collection | PubMed |
description | BACKGROUND AND OBJECTIVES: Collagen solder is capable of fixation of surgical meshes during laparoscopic herniorrhaphy without compromising tissue integration, increasing adhesions or inflammation. This pilot study describes development of instrumentation and techniques for transabdominal preperitoneal (TAPP) herniorrhaphy using laser-assisted soldering technology. METHODS: Anesthetized 20-kg to 25-kg female Yorkshire pigs underwent laparoscopy performed using a 3-trocar technique. Peritoneal incisions were made and pockets created in the preperitoneal space for mesh placement. Parietex TEC mesh segments embedded in 60% collagen-solder were soldered to the muscle surface by using a prototype laser (1.45µ, 4.5W CW, 5mm spot, and 55°C set temperature) and custom laparoscopic handpiece. Parietex TEC mesh segments (Control) were affixed to the muscle with fibrin sealant (Tisseel). Peritoneal closure was with staples (Control) or by soldering collagen embedded Vicryl mesh segments over the peritoneal incision (Mesh/TAPP). Segments were inserted using a specially designed introducer. Animals were recovered and underwent second-look laparoscopy at 6 weeks postimplantation. Mesh sites were harvested after animals were euthanized. RESULTS: The mesh-solder constructs were easily inserted and affixed in the TAPP approach. Tisseel tended to drip during application, particularly in vertical and ventral locations. Postoperative healing was similar to Control segments in all cases. Mesh/TAPP closures healed without scarring or adhesion formation. DISCUSSION AND CONCLUSION: Collagen-based tissue soldering permits normal wound healing and may mitigate or reduce use of staples for laparoscopic mesh fixation and peritoneal closure. Laser-assisted mesh fixation and peritoneal closure is a promising alternative for laparoscopic herniorrhaphy. Further development of this strategy is warranted. |
format | Text |
id | pubmed-3015923 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | Society of Laparoendoscopic Surgeons |
record_format | MEDLINE/PubMed |
spelling | pubmed-30159232011-02-17 Transabdominal Preperitoneal Herniorrhaphy using Laser-Assisted Tissue Soldering in a Porcine Model Lanzafame, Raymond J. Soltz, Barbara A. Stadler, Istvan Soltz, Robert JSLS Scientific Papers BACKGROUND AND OBJECTIVES: Collagen solder is capable of fixation of surgical meshes during laparoscopic herniorrhaphy without compromising tissue integration, increasing adhesions or inflammation. This pilot study describes development of instrumentation and techniques for transabdominal preperitoneal (TAPP) herniorrhaphy using laser-assisted soldering technology. METHODS: Anesthetized 20-kg to 25-kg female Yorkshire pigs underwent laparoscopy performed using a 3-trocar technique. Peritoneal incisions were made and pockets created in the preperitoneal space for mesh placement. Parietex TEC mesh segments embedded in 60% collagen-solder were soldered to the muscle surface by using a prototype laser (1.45µ, 4.5W CW, 5mm spot, and 55°C set temperature) and custom laparoscopic handpiece. Parietex TEC mesh segments (Control) were affixed to the muscle with fibrin sealant (Tisseel). Peritoneal closure was with staples (Control) or by soldering collagen embedded Vicryl mesh segments over the peritoneal incision (Mesh/TAPP). Segments were inserted using a specially designed introducer. Animals were recovered and underwent second-look laparoscopy at 6 weeks postimplantation. Mesh sites were harvested after animals were euthanized. RESULTS: The mesh-solder constructs were easily inserted and affixed in the TAPP approach. Tisseel tended to drip during application, particularly in vertical and ventral locations. Postoperative healing was similar to Control segments in all cases. Mesh/TAPP closures healed without scarring or adhesion formation. DISCUSSION AND CONCLUSION: Collagen-based tissue soldering permits normal wound healing and may mitigate or reduce use of staples for laparoscopic mesh fixation and peritoneal closure. Laser-assisted mesh fixation and peritoneal closure is a promising alternative for laparoscopic herniorrhaphy. Further development of this strategy is warranted. Society of Laparoendoscopic Surgeons 2009 /pmc/articles/PMC3015923/ /pubmed/19660214 Text en © 2009 by JSLS, Journal of the Society of Laparoendoscopic Surgeons. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits for noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited and is not altered in any way. |
spellingShingle | Scientific Papers Lanzafame, Raymond J. Soltz, Barbara A. Stadler, Istvan Soltz, Robert Transabdominal Preperitoneal Herniorrhaphy using Laser-Assisted Tissue Soldering in a Porcine Model |
title | Transabdominal Preperitoneal Herniorrhaphy using Laser-Assisted Tissue Soldering in a Porcine Model |
title_full | Transabdominal Preperitoneal Herniorrhaphy using Laser-Assisted Tissue Soldering in a Porcine Model |
title_fullStr | Transabdominal Preperitoneal Herniorrhaphy using Laser-Assisted Tissue Soldering in a Porcine Model |
title_full_unstemmed | Transabdominal Preperitoneal Herniorrhaphy using Laser-Assisted Tissue Soldering in a Porcine Model |
title_short | Transabdominal Preperitoneal Herniorrhaphy using Laser-Assisted Tissue Soldering in a Porcine Model |
title_sort | transabdominal preperitoneal herniorrhaphy using laser-assisted tissue soldering in a porcine model |
topic | Scientific Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3015923/ https://www.ncbi.nlm.nih.gov/pubmed/19660214 |
work_keys_str_mv | AT lanzafameraymondj transabdominalpreperitonealherniorrhaphyusinglaserassistedtissuesolderinginaporcinemodel AT soltzbarbaraa transabdominalpreperitonealherniorrhaphyusinglaserassistedtissuesolderinginaporcinemodel AT stadleristvan transabdominalpreperitonealherniorrhaphyusinglaserassistedtissuesolderinginaporcinemodel AT soltzrobert transabdominalpreperitonealherniorrhaphyusinglaserassistedtissuesolderinginaporcinemodel |