Cargando…

Making the Transition From Standard Gynecologic Laparoscopy to Robotic Laparoscopy

OBJECTIVES: To determine the feasibility of using a simple procedure, a bilateral tubal ligation, as a transition procedure when adopting robotic laparoscopy for gynecologic surgery. METHOD: To obtain robotic credentialing and gain experience with the robotic system, the surgeons first went through...

Descripción completa

Detalles Bibliográficos
Autores principales: Ferguson, Jennifer L., Beste, Todd M., Nelson, Keith H., Daucher, James A.
Formato: Texto
Lenguaje:English
Publicado: Society of Laparoendoscopic Surgeons 2004
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3016823/
https://www.ncbi.nlm.nih.gov/pubmed/15554274
_version_ 1782195819374444544
author Ferguson, Jennifer L.
Beste, Todd M.
Nelson, Keith H.
Daucher, James A.
author_facet Ferguson, Jennifer L.
Beste, Todd M.
Nelson, Keith H.
Daucher, James A.
author_sort Ferguson, Jennifer L.
collection PubMed
description OBJECTIVES: To determine the feasibility of using a simple procedure, a bilateral tubal ligation, as a transition procedure when adopting robotic laparoscopy for gynecologic surgery. METHOD: To obtain robotic credentialing and gain experience with the robotic system, the surgeons first went through robotic training, then 4 women desiring permanent sterilization had robotically assisted laparoscopic bilateral tubal ligations performed, using the Parkland method. RESULTS: Total operating room time varied from 1 hour 25 minutes to 2 hours 31 minutes. Improvement in operating time for each surgeon was noted with each successive case. Best times in robotic cases were similar to those of standard laparoscopy. CONCLUSION: Robotically assisted laparoscopic tubal ligation using the Parkland method is a satisfactory procedure to provide transition for gynecologic surgeons and operating room personnel to gynecologic robotic surgery.
format Text
id pubmed-3016823
institution National Center for Biotechnology Information
language English
publishDate 2004
publisher Society of Laparoendoscopic Surgeons
record_format MEDLINE/PubMed
spelling pubmed-30168232011-02-17 Making the Transition From Standard Gynecologic Laparoscopy to Robotic Laparoscopy Ferguson, Jennifer L. Beste, Todd M. Nelson, Keith H. Daucher, James A. JSLS Scientific Papers OBJECTIVES: To determine the feasibility of using a simple procedure, a bilateral tubal ligation, as a transition procedure when adopting robotic laparoscopy for gynecologic surgery. METHOD: To obtain robotic credentialing and gain experience with the robotic system, the surgeons first went through robotic training, then 4 women desiring permanent sterilization had robotically assisted laparoscopic bilateral tubal ligations performed, using the Parkland method. RESULTS: Total operating room time varied from 1 hour 25 minutes to 2 hours 31 minutes. Improvement in operating time for each surgeon was noted with each successive case. Best times in robotic cases were similar to those of standard laparoscopy. CONCLUSION: Robotically assisted laparoscopic tubal ligation using the Parkland method is a satisfactory procedure to provide transition for gynecologic surgeons and operating room personnel to gynecologic robotic surgery. Society of Laparoendoscopic Surgeons 2004 /pmc/articles/PMC3016823/ /pubmed/15554274 Text en © 2004 by JSLS, Journal of the Society of Laparoendoscopic Surgeons. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits for noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited and is not altered in any way.
spellingShingle Scientific Papers
Ferguson, Jennifer L.
Beste, Todd M.
Nelson, Keith H.
Daucher, James A.
Making the Transition From Standard Gynecologic Laparoscopy to Robotic Laparoscopy
title Making the Transition From Standard Gynecologic Laparoscopy to Robotic Laparoscopy
title_full Making the Transition From Standard Gynecologic Laparoscopy to Robotic Laparoscopy
title_fullStr Making the Transition From Standard Gynecologic Laparoscopy to Robotic Laparoscopy
title_full_unstemmed Making the Transition From Standard Gynecologic Laparoscopy to Robotic Laparoscopy
title_short Making the Transition From Standard Gynecologic Laparoscopy to Robotic Laparoscopy
title_sort making the transition from standard gynecologic laparoscopy to robotic laparoscopy
topic Scientific Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3016823/
https://www.ncbi.nlm.nih.gov/pubmed/15554274
work_keys_str_mv AT fergusonjenniferl makingthetransitionfromstandardgynecologiclaparoscopytoroboticlaparoscopy
AT bestetoddm makingthetransitionfromstandardgynecologiclaparoscopytoroboticlaparoscopy
AT nelsonkeithh makingthetransitionfromstandardgynecologiclaparoscopytoroboticlaparoscopy
AT daucherjamesa makingthetransitionfromstandardgynecologiclaparoscopytoroboticlaparoscopy