Cargando…

The Efficacy of the Coaxial Technique Using a 6-Fr Introducer Sheath in Stent Placement for Treating the Obstructions Proximal to the Descending Colon

OBJECTIVE: We wanted to evaluate the efficacy of stent placement using the coaxial technique with a stiff, long introducer sheath in patients with technical failure using an angiographic catheter for the obstructions proximal to the descending colon. MATERIALS AND METHODS: Self-expandable metallic s...

Descripción completa

Detalles Bibliográficos
Autores principales: Chang, Il Soo, Park, Sang Woo, Hwang, Dae-Yong, Seong, Moo Kyung, Joh, Hee-Kyung, Yoon, So Young, Cho, Yo-Han, Choe, Won Hyeok
Formato: Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3017874/
https://www.ncbi.nlm.nih.gov/pubmed/21228946
http://dx.doi.org/10.3348/kjr.2011.12.1.107
_version_ 1782195972888068096
author Chang, Il Soo
Park, Sang Woo
Hwang, Dae-Yong
Seong, Moo Kyung
Joh, Hee-Kyung
Yoon, So Young
Cho, Yo-Han
Choe, Won Hyeok
author_facet Chang, Il Soo
Park, Sang Woo
Hwang, Dae-Yong
Seong, Moo Kyung
Joh, Hee-Kyung
Yoon, So Young
Cho, Yo-Han
Choe, Won Hyeok
author_sort Chang, Il Soo
collection PubMed
description OBJECTIVE: We wanted to evaluate the efficacy of stent placement using the coaxial technique with a stiff, long introducer sheath in patients with technical failure using an angiographic catheter for the obstructions proximal to the descending colon. MATERIALS AND METHODS: Self-expandable metallic stent placement was attempted under fluoroscopy-guidance in 77 consecutive patients who had malignant colorectal obstruction. Stent placement was performed using an angiographic catheter and a guide wire. If the angiographic catheter could not be advanced over the guide wire into the obstructive lesions proximal to the descending colon, then a 6-Fr introducer sheath was used. The technical success rate, the clinical success rate and the complications were analyzed. RESULTS: Successful stent placement was achieved in 75 of 77 patients (97%). The angiographic catheter failed to advance into the obstructive lesions of 11 patients (M:F = 7:4; mean age, 65.5 years) whose lesions were at the level of the splenic flexure or transverse colon. Therefore, the coaxial technique was implemented in all these 11 patients using a 6-Fr stiff introducer sheath and then the stent placement was successful. There were no complications related to the use of a stiff introducer sheath. Clinical success, which was defined as relief of clinical obstructive bowel symptoms, was obtained within 24 hours in all of patients. CONCLUSION: The coaxial technique using a stiff introducer sheath can increase the technical success of fluoroscopy-guided, self-expandable metallic stent placement in patients with colonic obstruction proximal to the descending colon.
format Text
id pubmed-3017874
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-30178742011-01-12 The Efficacy of the Coaxial Technique Using a 6-Fr Introducer Sheath in Stent Placement for Treating the Obstructions Proximal to the Descending Colon Chang, Il Soo Park, Sang Woo Hwang, Dae-Yong Seong, Moo Kyung Joh, Hee-Kyung Yoon, So Young Cho, Yo-Han Choe, Won Hyeok Korean J Radiol Original Article OBJECTIVE: We wanted to evaluate the efficacy of stent placement using the coaxial technique with a stiff, long introducer sheath in patients with technical failure using an angiographic catheter for the obstructions proximal to the descending colon. MATERIALS AND METHODS: Self-expandable metallic stent placement was attempted under fluoroscopy-guidance in 77 consecutive patients who had malignant colorectal obstruction. Stent placement was performed using an angiographic catheter and a guide wire. If the angiographic catheter could not be advanced over the guide wire into the obstructive lesions proximal to the descending colon, then a 6-Fr introducer sheath was used. The technical success rate, the clinical success rate and the complications were analyzed. RESULTS: Successful stent placement was achieved in 75 of 77 patients (97%). The angiographic catheter failed to advance into the obstructive lesions of 11 patients (M:F = 7:4; mean age, 65.5 years) whose lesions were at the level of the splenic flexure or transverse colon. Therefore, the coaxial technique was implemented in all these 11 patients using a 6-Fr stiff introducer sheath and then the stent placement was successful. There were no complications related to the use of a stiff introducer sheath. Clinical success, which was defined as relief of clinical obstructive bowel symptoms, was obtained within 24 hours in all of patients. CONCLUSION: The coaxial technique using a stiff introducer sheath can increase the technical success of fluoroscopy-guided, self-expandable metallic stent placement in patients with colonic obstruction proximal to the descending colon. The Korean Society of Radiology 2011 2011-01-03 /pmc/articles/PMC3017874/ /pubmed/21228946 http://dx.doi.org/10.3348/kjr.2011.12.1.107 Text en Copyright © 2011 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Chang, Il Soo
Park, Sang Woo
Hwang, Dae-Yong
Seong, Moo Kyung
Joh, Hee-Kyung
Yoon, So Young
Cho, Yo-Han
Choe, Won Hyeok
The Efficacy of the Coaxial Technique Using a 6-Fr Introducer Sheath in Stent Placement for Treating the Obstructions Proximal to the Descending Colon
title The Efficacy of the Coaxial Technique Using a 6-Fr Introducer Sheath in Stent Placement for Treating the Obstructions Proximal to the Descending Colon
title_full The Efficacy of the Coaxial Technique Using a 6-Fr Introducer Sheath in Stent Placement for Treating the Obstructions Proximal to the Descending Colon
title_fullStr The Efficacy of the Coaxial Technique Using a 6-Fr Introducer Sheath in Stent Placement for Treating the Obstructions Proximal to the Descending Colon
title_full_unstemmed The Efficacy of the Coaxial Technique Using a 6-Fr Introducer Sheath in Stent Placement for Treating the Obstructions Proximal to the Descending Colon
title_short The Efficacy of the Coaxial Technique Using a 6-Fr Introducer Sheath in Stent Placement for Treating the Obstructions Proximal to the Descending Colon
title_sort efficacy of the coaxial technique using a 6-fr introducer sheath in stent placement for treating the obstructions proximal to the descending colon
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3017874/
https://www.ncbi.nlm.nih.gov/pubmed/21228946
http://dx.doi.org/10.3348/kjr.2011.12.1.107
work_keys_str_mv AT changilsoo theefficacyofthecoaxialtechniqueusinga6frintroducersheathinstentplacementfortreatingtheobstructionsproximaltothedescendingcolon
AT parksangwoo theefficacyofthecoaxialtechniqueusinga6frintroducersheathinstentplacementfortreatingtheobstructionsproximaltothedescendingcolon
AT hwangdaeyong theefficacyofthecoaxialtechniqueusinga6frintroducersheathinstentplacementfortreatingtheobstructionsproximaltothedescendingcolon
AT seongmookyung theefficacyofthecoaxialtechniqueusinga6frintroducersheathinstentplacementfortreatingtheobstructionsproximaltothedescendingcolon
AT johheekyung theefficacyofthecoaxialtechniqueusinga6frintroducersheathinstentplacementfortreatingtheobstructionsproximaltothedescendingcolon
AT yoonsoyoung theefficacyofthecoaxialtechniqueusinga6frintroducersheathinstentplacementfortreatingtheobstructionsproximaltothedescendingcolon
AT choyohan theefficacyofthecoaxialtechniqueusinga6frintroducersheathinstentplacementfortreatingtheobstructionsproximaltothedescendingcolon
AT choewonhyeok theefficacyofthecoaxialtechniqueusinga6frintroducersheathinstentplacementfortreatingtheobstructionsproximaltothedescendingcolon
AT changilsoo efficacyofthecoaxialtechniqueusinga6frintroducersheathinstentplacementfortreatingtheobstructionsproximaltothedescendingcolon
AT parksangwoo efficacyofthecoaxialtechniqueusinga6frintroducersheathinstentplacementfortreatingtheobstructionsproximaltothedescendingcolon
AT hwangdaeyong efficacyofthecoaxialtechniqueusinga6frintroducersheathinstentplacementfortreatingtheobstructionsproximaltothedescendingcolon
AT seongmookyung efficacyofthecoaxialtechniqueusinga6frintroducersheathinstentplacementfortreatingtheobstructionsproximaltothedescendingcolon
AT johheekyung efficacyofthecoaxialtechniqueusinga6frintroducersheathinstentplacementfortreatingtheobstructionsproximaltothedescendingcolon
AT yoonsoyoung efficacyofthecoaxialtechniqueusinga6frintroducersheathinstentplacementfortreatingtheobstructionsproximaltothedescendingcolon
AT choyohan efficacyofthecoaxialtechniqueusinga6frintroducersheathinstentplacementfortreatingtheobstructionsproximaltothedescendingcolon
AT choewonhyeok efficacyofthecoaxialtechniqueusinga6frintroducersheathinstentplacementfortreatingtheobstructionsproximaltothedescendingcolon