Cargando…
Interlaced spectrally encoded confocal scanning laser ophthalmoscopy and spectral domain optical coherence tomography
Scanning laser ophthalmoscopy (SLO) and spectral domain optical coherence tomography (SDOCT) have become essential clinical diagnostic tools in ophthalmology by allowing for video-rate noninvasive en face and depth-resolved visualization of retinal structure. Current generation multimodal imaging sy...
Autores principales: | , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Optical Society of America
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3017990/ https://www.ncbi.nlm.nih.gov/pubmed/21258478 http://dx.doi.org/10.1364/BOE.1.000431 |
_version_ | 1782196001101053952 |
---|---|
author | Tao, Yuankai K. Farsiu, Sina Izatt, Joseph A. |
author_facet | Tao, Yuankai K. Farsiu, Sina Izatt, Joseph A. |
author_sort | Tao, Yuankai K. |
collection | PubMed |
description | Scanning laser ophthalmoscopy (SLO) and spectral domain optical coherence tomography (SDOCT) have become essential clinical diagnostic tools in ophthalmology by allowing for video-rate noninvasive en face and depth-resolved visualization of retinal structure. Current generation multimodal imaging systems that combine both SLO and OCT as a means of image tracking remain complex in their hardware implementations. Here, we combine a spectrally encoded confocal scanning laser ophthalmoscope (SECSLO) with an ophthalmic SDOCT system. This novel implementation of an interlaced SECSLO-SDOCT system allows for video-rate SLO fundus images to be acquired alternately with high-resolution SDOCT B-scans as a means of image aiming, guidance, and registration as well as motion tracking. The system shares the illumination source, detection system, and scanning optics between both SLO and OCT as a method of providing a simple multimodal ophthalmic imaging system that can readily be implemented as a table-top or hand-held device. |
format | Text |
id | pubmed-3017990 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Optical Society of America |
record_format | MEDLINE/PubMed |
spelling | pubmed-30179902011-01-21 Interlaced spectrally encoded confocal scanning laser ophthalmoscopy and spectral domain optical coherence tomography Tao, Yuankai K. Farsiu, Sina Izatt, Joseph A. Biomed Opt Express Ophthalmology Applications Scanning laser ophthalmoscopy (SLO) and spectral domain optical coherence tomography (SDOCT) have become essential clinical diagnostic tools in ophthalmology by allowing for video-rate noninvasive en face and depth-resolved visualization of retinal structure. Current generation multimodal imaging systems that combine both SLO and OCT as a means of image tracking remain complex in their hardware implementations. Here, we combine a spectrally encoded confocal scanning laser ophthalmoscope (SECSLO) with an ophthalmic SDOCT system. This novel implementation of an interlaced SECSLO-SDOCT system allows for video-rate SLO fundus images to be acquired alternately with high-resolution SDOCT B-scans as a means of image aiming, guidance, and registration as well as motion tracking. The system shares the illumination source, detection system, and scanning optics between both SLO and OCT as a method of providing a simple multimodal ophthalmic imaging system that can readily be implemented as a table-top or hand-held device. Optical Society of America 2010-08-02 /pmc/articles/PMC3017990/ /pubmed/21258478 http://dx.doi.org/10.1364/BOE.1.000431 Text en ©2010 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially. |
spellingShingle | Ophthalmology Applications Tao, Yuankai K. Farsiu, Sina Izatt, Joseph A. Interlaced spectrally encoded confocal scanning laser ophthalmoscopy and spectral domain optical coherence tomography |
title | Interlaced spectrally encoded confocal scanning laser ophthalmoscopy and spectral domain optical coherence tomography |
title_full | Interlaced spectrally encoded confocal scanning laser ophthalmoscopy and spectral domain optical coherence tomography |
title_fullStr | Interlaced spectrally encoded confocal scanning laser ophthalmoscopy and spectral domain optical coherence tomography |
title_full_unstemmed | Interlaced spectrally encoded confocal scanning laser ophthalmoscopy and spectral domain optical coherence tomography |
title_short | Interlaced spectrally encoded confocal scanning laser ophthalmoscopy and spectral domain optical coherence tomography |
title_sort | interlaced spectrally encoded confocal scanning laser ophthalmoscopy and spectral domain optical coherence tomography |
topic | Ophthalmology Applications |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3017990/ https://www.ncbi.nlm.nih.gov/pubmed/21258478 http://dx.doi.org/10.1364/BOE.1.000431 |
work_keys_str_mv | AT taoyuankaik interlacedspectrallyencodedconfocalscanninglaserophthalmoscopyandspectraldomainopticalcoherencetomography AT farsiusina interlacedspectrallyencodedconfocalscanninglaserophthalmoscopyandspectraldomainopticalcoherencetomography AT izattjosepha interlacedspectrallyencodedconfocalscanninglaserophthalmoscopyandspectraldomainopticalcoherencetomography |