Cargando…
Implementation of a continuous scanning procedure and a line scan camera for thin-sheet laser imaging microscopy
We report development of a continuous scanning procedure and the use of a time delay integration (TDI) line scan camera for a light-sheet based microscope called a thin-sheet laser imaging microscope (TSLIM). TSLIM is an optimized version of a light-sheet fluorescent microscope that previously used...
Autores principales: | , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Optical Society of America
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3018006/ https://www.ncbi.nlm.nih.gov/pubmed/21258493 http://dx.doi.org/10.1364/BOE.1.000598/ |
_version_ | 1782196005504024576 |
---|---|
author | Schacht, Peter Johnson, Shane B. Santi, Peter A. |
author_facet | Schacht, Peter Johnson, Shane B. Santi, Peter A. |
author_sort | Schacht, Peter |
collection | PubMed |
description | We report development of a continuous scanning procedure and the use of a time delay integration (TDI) line scan camera for a light-sheet based microscope called a thin-sheet laser imaging microscope (TSLIM). TSLIM is an optimized version of a light-sheet fluorescent microscope that previously used a start/stop scanning procedure to move the specimen through the thinnest portion of a light-sheet and stitched the image columns together to produce a well-focused composite image. In this paper, hardware and software enhancements to TSLIM are described that allow for dual sided, dual illumination lasers, and continuous scanning of the specimen using either a full-frame CCD camera and a TDI line scan camera. These enhancements provided a ~70% reduction in the time required for composite image generation and a ~63% reduction in photobleaching of the specimen compared to the start/stop procedure. |
format | Text |
id | pubmed-3018006 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Optical Society of America |
record_format | MEDLINE/PubMed |
spelling | pubmed-30180062011-01-21 Implementation of a continuous scanning procedure and a line scan camera for
thin-sheet laser imaging microscopy Schacht, Peter Johnson, Shane B. Santi, Peter A. Biomed Opt Express Microscopy We report development of a continuous scanning procedure and the use of a time delay integration (TDI) line scan camera for a light-sheet based microscope called a thin-sheet laser imaging microscope (TSLIM). TSLIM is an optimized version of a light-sheet fluorescent microscope that previously used a start/stop scanning procedure to move the specimen through the thinnest portion of a light-sheet and stitched the image columns together to produce a well-focused composite image. In this paper, hardware and software enhancements to TSLIM are described that allow for dual sided, dual illumination lasers, and continuous scanning of the specimen using either a full-frame CCD camera and a TDI line scan camera. These enhancements provided a ~70% reduction in the time required for composite image generation and a ~63% reduction in photobleaching of the specimen compared to the start/stop procedure. Optical Society of America 2010-08-13 /pmc/articles/PMC3018006/ /pubmed/21258493 http://dx.doi.org/10.1364/BOE.1.000598/ Text en ©2010 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially. |
spellingShingle | Microscopy Schacht, Peter Johnson, Shane B. Santi, Peter A. Implementation of a continuous scanning procedure and a line scan camera for thin-sheet laser imaging microscopy |
title | Implementation of a continuous scanning procedure and a line scan camera for
thin-sheet laser imaging microscopy |
title_full | Implementation of a continuous scanning procedure and a line scan camera for
thin-sheet laser imaging microscopy |
title_fullStr | Implementation of a continuous scanning procedure and a line scan camera for
thin-sheet laser imaging microscopy |
title_full_unstemmed | Implementation of a continuous scanning procedure and a line scan camera for
thin-sheet laser imaging microscopy |
title_short | Implementation of a continuous scanning procedure and a line scan camera for
thin-sheet laser imaging microscopy |
title_sort | implementation of a continuous scanning procedure and a line scan camera for
thin-sheet laser imaging microscopy |
topic | Microscopy |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3018006/ https://www.ncbi.nlm.nih.gov/pubmed/21258493 http://dx.doi.org/10.1364/BOE.1.000598/ |
work_keys_str_mv | AT schachtpeter implementationofacontinuousscanningprocedureandalinescancameraforthinsheetlaserimagingmicroscopy AT johnsonshaneb implementationofacontinuousscanningprocedureandalinescancameraforthinsheetlaserimagingmicroscopy AT santipetera implementationofacontinuousscanningprocedureandalinescancameraforthinsheetlaserimagingmicroscopy |