Cargando…

Investigation of spectral interferences on the accuracy of broadband CW-NIRS tissue SO(2) determination

An accurate SO(2) prediction method for using broadband continuous-wave diffuse reflectance near infrared (NIR) spectroscopy is proposed. The method fitted the NIR spectra to a Taylor expansion attenuation model, and used the simulated annealing method to initialize the nonlinear least squares fit....

Descripción completa

Detalles Bibliográficos
Autores principales: Zou, Fengmei, Jin, Chunguang, Ross, Randy R., Soller, Babs
Formato: Texto
Lenguaje:English
Publicado: Optical Society of America 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3018045/
https://www.ncbi.nlm.nih.gov/pubmed/21258506
http://dx.doi.org/10.1364/BOE.1.000748
_version_ 1782196009511682048
author Zou, Fengmei
Jin, Chunguang
Ross, Randy R.
Soller, Babs
author_facet Zou, Fengmei
Jin, Chunguang
Ross, Randy R.
Soller, Babs
author_sort Zou, Fengmei
collection PubMed
description An accurate SO(2) prediction method for using broadband continuous-wave diffuse reflectance near infrared (NIR) spectroscopy is proposed. The method fitted the NIR spectra to a Taylor expansion attenuation model, and used the simulated annealing method to initialize the nonlinear least squares fit. This paper investigated the effect of potential spectral interferences that are likely to be encountered in clinical use, on SO(2) prediction accuracy. The factors include the concentration of hemoglobin in blood, the volume of blood and volume of water in the tissue under the sensor, reduced scattering coefficient, µ(s)', of the muscle, fat thickness and the source-detector spacing. The SO(2) prediction method was evaluated on simulated muscle spectra as well as on dual-dye phantoms which simulate the absorbance of oxygenated and deoxygenated hemoglobin.
format Text
id pubmed-3018045
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Optical Society of America
record_format MEDLINE/PubMed
spelling pubmed-30180452011-01-21 Investigation of spectral interferences on the accuracy of broadband CW-NIRS tissue SO(2) determination Zou, Fengmei Jin, Chunguang Ross, Randy R. Soller, Babs Biomed Opt Express Spectroscopic Diagnostics An accurate SO(2) prediction method for using broadband continuous-wave diffuse reflectance near infrared (NIR) spectroscopy is proposed. The method fitted the NIR spectra to a Taylor expansion attenuation model, and used the simulated annealing method to initialize the nonlinear least squares fit. This paper investigated the effect of potential spectral interferences that are likely to be encountered in clinical use, on SO(2) prediction accuracy. The factors include the concentration of hemoglobin in blood, the volume of blood and volume of water in the tissue under the sensor, reduced scattering coefficient, µ(s)', of the muscle, fat thickness and the source-detector spacing. The SO(2) prediction method was evaluated on simulated muscle spectra as well as on dual-dye phantoms which simulate the absorbance of oxygenated and deoxygenated hemoglobin. Optical Society of America 2010-08-30 /pmc/articles/PMC3018045/ /pubmed/21258506 http://dx.doi.org/10.1364/BOE.1.000748 Text en ©2010 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially.
spellingShingle Spectroscopic Diagnostics
Zou, Fengmei
Jin, Chunguang
Ross, Randy R.
Soller, Babs
Investigation of spectral interferences on the accuracy of broadband CW-NIRS tissue SO(2) determination
title Investigation of spectral interferences on the accuracy of broadband CW-NIRS tissue SO(2) determination
title_full Investigation of spectral interferences on the accuracy of broadband CW-NIRS tissue SO(2) determination
title_fullStr Investigation of spectral interferences on the accuracy of broadband CW-NIRS tissue SO(2) determination
title_full_unstemmed Investigation of spectral interferences on the accuracy of broadband CW-NIRS tissue SO(2) determination
title_short Investigation of spectral interferences on the accuracy of broadband CW-NIRS tissue SO(2) determination
title_sort investigation of spectral interferences on the accuracy of broadband cw-nirs tissue so(2) determination
topic Spectroscopic Diagnostics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3018045/
https://www.ncbi.nlm.nih.gov/pubmed/21258506
http://dx.doi.org/10.1364/BOE.1.000748
work_keys_str_mv AT zoufengmei investigationofspectralinterferencesontheaccuracyofbroadbandcwnirstissueso2determination
AT jinchunguang investigationofspectralinterferencesontheaccuracyofbroadbandcwnirstissueso2determination
AT rossrandyr investigationofspectralinterferencesontheaccuracyofbroadbandcwnirstissueso2determination
AT sollerbabs investigationofspectralinterferencesontheaccuracyofbroadbandcwnirstissueso2determination