Cargando…
Investigation of spectral interferences on the accuracy of broadband CW-NIRS tissue SO(2) determination
An accurate SO(2) prediction method for using broadband continuous-wave diffuse reflectance near infrared (NIR) spectroscopy is proposed. The method fitted the NIR spectra to a Taylor expansion attenuation model, and used the simulated annealing method to initialize the nonlinear least squares fit....
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Optical Society of America
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3018045/ https://www.ncbi.nlm.nih.gov/pubmed/21258506 http://dx.doi.org/10.1364/BOE.1.000748 |
_version_ | 1782196009511682048 |
---|---|
author | Zou, Fengmei Jin, Chunguang Ross, Randy R. Soller, Babs |
author_facet | Zou, Fengmei Jin, Chunguang Ross, Randy R. Soller, Babs |
author_sort | Zou, Fengmei |
collection | PubMed |
description | An accurate SO(2) prediction method for using broadband continuous-wave diffuse reflectance near infrared (NIR) spectroscopy is proposed. The method fitted the NIR spectra to a Taylor expansion attenuation model, and used the simulated annealing method to initialize the nonlinear least squares fit. This paper investigated the effect of potential spectral interferences that are likely to be encountered in clinical use, on SO(2) prediction accuracy. The factors include the concentration of hemoglobin in blood, the volume of blood and volume of water in the tissue under the sensor, reduced scattering coefficient, µ(s)', of the muscle, fat thickness and the source-detector spacing. The SO(2) prediction method was evaluated on simulated muscle spectra as well as on dual-dye phantoms which simulate the absorbance of oxygenated and deoxygenated hemoglobin. |
format | Text |
id | pubmed-3018045 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Optical Society of America |
record_format | MEDLINE/PubMed |
spelling | pubmed-30180452011-01-21 Investigation of spectral interferences on the accuracy of broadband CW-NIRS tissue SO(2) determination Zou, Fengmei Jin, Chunguang Ross, Randy R. Soller, Babs Biomed Opt Express Spectroscopic Diagnostics An accurate SO(2) prediction method for using broadband continuous-wave diffuse reflectance near infrared (NIR) spectroscopy is proposed. The method fitted the NIR spectra to a Taylor expansion attenuation model, and used the simulated annealing method to initialize the nonlinear least squares fit. This paper investigated the effect of potential spectral interferences that are likely to be encountered in clinical use, on SO(2) prediction accuracy. The factors include the concentration of hemoglobin in blood, the volume of blood and volume of water in the tissue under the sensor, reduced scattering coefficient, µ(s)', of the muscle, fat thickness and the source-detector spacing. The SO(2) prediction method was evaluated on simulated muscle spectra as well as on dual-dye phantoms which simulate the absorbance of oxygenated and deoxygenated hemoglobin. Optical Society of America 2010-08-30 /pmc/articles/PMC3018045/ /pubmed/21258506 http://dx.doi.org/10.1364/BOE.1.000748 Text en ©2010 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially. |
spellingShingle | Spectroscopic Diagnostics Zou, Fengmei Jin, Chunguang Ross, Randy R. Soller, Babs Investigation of spectral interferences on the accuracy of broadband CW-NIRS tissue SO(2) determination |
title | Investigation of spectral interferences on the accuracy of broadband CW-NIRS tissue SO(2) determination |
title_full | Investigation of spectral interferences on the accuracy of broadband CW-NIRS tissue SO(2) determination |
title_fullStr | Investigation of spectral interferences on the accuracy of broadband CW-NIRS tissue SO(2) determination |
title_full_unstemmed | Investigation of spectral interferences on the accuracy of broadband CW-NIRS tissue SO(2) determination |
title_short | Investigation of spectral interferences on the accuracy of broadband CW-NIRS tissue SO(2) determination |
title_sort | investigation of spectral interferences on the accuracy of broadband cw-nirs tissue so(2) determination |
topic | Spectroscopic Diagnostics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3018045/ https://www.ncbi.nlm.nih.gov/pubmed/21258506 http://dx.doi.org/10.1364/BOE.1.000748 |
work_keys_str_mv | AT zoufengmei investigationofspectralinterferencesontheaccuracyofbroadbandcwnirstissueso2determination AT jinchunguang investigationofspectralinterferencesontheaccuracyofbroadbandcwnirstissueso2determination AT rossrandyr investigationofspectralinterferencesontheaccuracyofbroadbandcwnirstissueso2determination AT sollerbabs investigationofspectralinterferencesontheaccuracyofbroadbandcwnirstissueso2determination |