AIMS: To compare long-term variability (LTV) in short-wavelength automated perimetry (SWAP) with that of standard white-on-white (W-W) perimetry, in primary open angle glaucoma (POAG) patients and normal subjects and to determine its clinical significance. PATIENTS AND METHODS: The sample comprised...

Descripción completa

Detalles Bibliográficos
Autor principal: Malhotra, Chintan
Formato: Texto
Lenguaje:English
Publicado: Medknow Publications 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3018102/
https://www.ncbi.nlm.nih.gov/pubmed/21234221
http://dx.doi.org/10.4103/0974-620X.48419
_version_ 1782196022774071296
author Malhotra, Chintan
author_facet Malhotra, Chintan
author_sort Malhotra, Chintan
collection PubMed
description AIMS: To compare long-term variability (LTV) in short-wavelength automated perimetry (SWAP) with that of standard white-on-white (W-W) perimetry, in primary open angle glaucoma (POAG) patients and normal subjects and to determine its clinical significance. PATIENTS AND METHODS: The sample comprised 30 patients of stable POAG (group 1) and 20 age-matched normal controls (group2) who performed both SWAP and W-W perimetry thrice at monthly intervals. Long-term variability at each location in the visual field was calculated as the standard deviation of three threshold decibel values taken from the three visual fields performed. Mean LTV was then calculated for the entire field for each subgroup and compared. RESULTS: Mean LTV in SWAP and W-W perimetry in glaucoma patients was 3.01 ± 0.74 dB and 2.73 ± 1.07dB respectively. In normal subjects mean LTV of SWAP and W-W perimetry was 2.69 ± 0.91 db and 1.97 ± 1.34 dB respectively. Intra group analysis revealed that mean LTV of SWAP was greater compared to W-W perimetry in normal subjects and glaucoma patients. In the latter, the difference did not reach statistical significance. Inter group analysis showed that mean LTV in both SWAP and W-W perimetry was greater in glaucoma patients than in normal subjects. Factors other than POAG that could influence LTV, including progression of cataract and change in pupil size due to use of pilocarpine were excluded. Mean examination time for SWAP per sitting was 7.65% longer than that for W-W perimetry. CONCLUSIONS: Higher mean LTV of SWAP as compared to W-W perimetry needs to be taken into consideration when evaluating serial visual fields for change. Use of rapid threshold algorithms e.g. SITA (Swedish interactive test algorithm) SWAP should be encouraged as these will reduce the patient fatigue and increase the reliability of the test.
format Text
id pubmed-3018102
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Medknow Publications
record_format MEDLINE/PubMed
spelling pubmed-30181022011-01-13 Long-term variability in short-wavelength automated perimetry compared to standard perimetry in glaucoma patients and normal subjects Malhotra, Chintan Oman J Ophthalmol Original Article AIMS: To compare long-term variability (LTV) in short-wavelength automated perimetry (SWAP) with that of standard white-on-white (W-W) perimetry, in primary open angle glaucoma (POAG) patients and normal subjects and to determine its clinical significance. PATIENTS AND METHODS: The sample comprised 30 patients of stable POAG (group 1) and 20 age-matched normal controls (group2) who performed both SWAP and W-W perimetry thrice at monthly intervals. Long-term variability at each location in the visual field was calculated as the standard deviation of three threshold decibel values taken from the three visual fields performed. Mean LTV was then calculated for the entire field for each subgroup and compared. RESULTS: Mean LTV in SWAP and W-W perimetry in glaucoma patients was 3.01 ± 0.74 dB and 2.73 ± 1.07dB respectively. In normal subjects mean LTV of SWAP and W-W perimetry was 2.69 ± 0.91 db and 1.97 ± 1.34 dB respectively. Intra group analysis revealed that mean LTV of SWAP was greater compared to W-W perimetry in normal subjects and glaucoma patients. In the latter, the difference did not reach statistical significance. Inter group analysis showed that mean LTV in both SWAP and W-W perimetry was greater in glaucoma patients than in normal subjects. Factors other than POAG that could influence LTV, including progression of cataract and change in pupil size due to use of pilocarpine were excluded. Mean examination time for SWAP per sitting was 7.65% longer than that for W-W perimetry. CONCLUSIONS: Higher mean LTV of SWAP as compared to W-W perimetry needs to be taken into consideration when evaluating serial visual fields for change. Use of rapid threshold algorithms e.g. SITA (Swedish interactive test algorithm) SWAP should be encouraged as these will reduce the patient fatigue and increase the reliability of the test. Medknow Publications 2009 /pmc/articles/PMC3018102/ /pubmed/21234221 http://dx.doi.org/10.4103/0974-620X.48419 Text en © Oman Journal of Ophthalmology http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Malhotra, Chintan
Long-term variability in short-wavelength automated perimetry compared to standard perimetry in glaucoma patients and normal subjects
title Long-term variability in short-wavelength automated perimetry compared to standard perimetry in glaucoma patients and normal subjects
title_full Long-term variability in short-wavelength automated perimetry compared to standard perimetry in glaucoma patients and normal subjects
title_fullStr Long-term variability in short-wavelength automated perimetry compared to standard perimetry in glaucoma patients and normal subjects
title_full_unstemmed Long-term variability in short-wavelength automated perimetry compared to standard perimetry in glaucoma patients and normal subjects
title_short Long-term variability in short-wavelength automated perimetry compared to standard perimetry in glaucoma patients and normal subjects
title_sort long-term variability in short-wavelength automated perimetry compared to standard perimetry in glaucoma patients and normal subjects
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3018102/
https://www.ncbi.nlm.nih.gov/pubmed/21234221
http://dx.doi.org/10.4103/0974-620X.48419
work_keys_str_mv AT malhotrachintan longtermvariabilityinshortwavelengthautomatedperimetrycomparedtostandardperimetryinglaucomapatientsandnormalsubjects