Cargando…
Full-range imaging of eye accommodation by high-speed long-depth range optical frequency domain imaging
We describe a high-speed long-depth range optical frequency domain imaging (OFDI) system employing a long-coherence length tunable source and demonstrate dynamic full-range imaging of the anterior segment of the eye including from the cornea surface to the posterior capsule of the crystalline lens w...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Optical Society of America
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3018118/ https://www.ncbi.nlm.nih.gov/pubmed/21258564 http://dx.doi.org/10.1364/BOE.1.001491 |
_version_ | 1782196027172847616 |
---|---|
author | Furukawa, Hiroyuki Hiro-Oka, Hideaki Satoh, Nobuyuki Yoshimura, Reiko Choi, Donghak Nakanishi, Motoi Igarashi, Akihito Ishikawa, Hitoshi Ohbayashi, Kohji Shimizu, Kimiya |
author_facet | Furukawa, Hiroyuki Hiro-Oka, Hideaki Satoh, Nobuyuki Yoshimura, Reiko Choi, Donghak Nakanishi, Motoi Igarashi, Akihito Ishikawa, Hitoshi Ohbayashi, Kohji Shimizu, Kimiya |
author_sort | Furukawa, Hiroyuki |
collection | PubMed |
description | We describe a high-speed long-depth range optical frequency domain imaging (OFDI) system employing a long-coherence length tunable source and demonstrate dynamic full-range imaging of the anterior segment of the eye including from the cornea surface to the posterior capsule of the crystalline lens with a depth range of 12 mm without removing complex conjugate image ambiguity. The tunable source spanned from 1260 to 1360 nm with an average output power of 15.8 mW. The fast A-scan rate of 20,000 per second provided dynamic OFDI and dependence of the whole anterior segment change on time following abrupt relaxation from the accommodated to the relaxed status, which was measured for a healthy eye and that with an intraocular lens. |
format | Text |
id | pubmed-3018118 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Optical Society of America |
record_format | MEDLINE/PubMed |
spelling | pubmed-30181182011-01-21 Full-range imaging of eye accommodation by high-speed long-depth range optical frequency domain imaging Furukawa, Hiroyuki Hiro-Oka, Hideaki Satoh, Nobuyuki Yoshimura, Reiko Choi, Donghak Nakanishi, Motoi Igarashi, Akihito Ishikawa, Hitoshi Ohbayashi, Kohji Shimizu, Kimiya Biomed Opt Express Ophthalmology Applications We describe a high-speed long-depth range optical frequency domain imaging (OFDI) system employing a long-coherence length tunable source and demonstrate dynamic full-range imaging of the anterior segment of the eye including from the cornea surface to the posterior capsule of the crystalline lens with a depth range of 12 mm without removing complex conjugate image ambiguity. The tunable source spanned from 1260 to 1360 nm with an average output power of 15.8 mW. The fast A-scan rate of 20,000 per second provided dynamic OFDI and dependence of the whole anterior segment change on time following abrupt relaxation from the accommodated to the relaxed status, which was measured for a healthy eye and that with an intraocular lens. Optical Society of America 2010-11-23 /pmc/articles/PMC3018118/ /pubmed/21258564 http://dx.doi.org/10.1364/BOE.1.001491 Text en ©2010 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially. |
spellingShingle | Ophthalmology Applications Furukawa, Hiroyuki Hiro-Oka, Hideaki Satoh, Nobuyuki Yoshimura, Reiko Choi, Donghak Nakanishi, Motoi Igarashi, Akihito Ishikawa, Hitoshi Ohbayashi, Kohji Shimizu, Kimiya Full-range imaging of eye accommodation by high-speed long-depth range optical frequency domain imaging |
title | Full-range imaging of eye accommodation by high-speed long-depth range optical frequency domain imaging |
title_full | Full-range imaging of eye accommodation by high-speed long-depth range optical frequency domain imaging |
title_fullStr | Full-range imaging of eye accommodation by high-speed long-depth range optical frequency domain imaging |
title_full_unstemmed | Full-range imaging of eye accommodation by high-speed long-depth range optical frequency domain imaging |
title_short | Full-range imaging of eye accommodation by high-speed long-depth range optical frequency domain imaging |
title_sort | full-range imaging of eye accommodation by high-speed long-depth range optical frequency domain imaging |
topic | Ophthalmology Applications |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3018118/ https://www.ncbi.nlm.nih.gov/pubmed/21258564 http://dx.doi.org/10.1364/BOE.1.001491 |
work_keys_str_mv | AT furukawahiroyuki fullrangeimagingofeyeaccommodationbyhighspeedlongdepthrangeopticalfrequencydomainimaging AT hirookahideaki fullrangeimagingofeyeaccommodationbyhighspeedlongdepthrangeopticalfrequencydomainimaging AT satohnobuyuki fullrangeimagingofeyeaccommodationbyhighspeedlongdepthrangeopticalfrequencydomainimaging AT yoshimurareiko fullrangeimagingofeyeaccommodationbyhighspeedlongdepthrangeopticalfrequencydomainimaging AT choidonghak fullrangeimagingofeyeaccommodationbyhighspeedlongdepthrangeopticalfrequencydomainimaging AT nakanishimotoi fullrangeimagingofeyeaccommodationbyhighspeedlongdepthrangeopticalfrequencydomainimaging AT igarashiakihito fullrangeimagingofeyeaccommodationbyhighspeedlongdepthrangeopticalfrequencydomainimaging AT ishikawahitoshi fullrangeimagingofeyeaccommodationbyhighspeedlongdepthrangeopticalfrequencydomainimaging AT ohbayashikohji fullrangeimagingofeyeaccommodationbyhighspeedlongdepthrangeopticalfrequencydomainimaging AT shimizukimiya fullrangeimagingofeyeaccommodationbyhighspeedlongdepthrangeopticalfrequencydomainimaging |