Cargando…

The reliability of toe systolic pressure and the toe brachial index in patients with diabetes

BACKGROUND: The Ankle Brachial Index is a useful clinical test for establishing blood supply to the foot. However, there are limitations to this method when conducted on people with diabetes. As an alternative to the Ankle Brachial Index, measuring Toe Systolic Pressures and the Toe Brachial Index h...

Descripción completa

Detalles Bibliográficos
Autores principales: Romanos, Mary T, Raspovic, Anita, Perrin, Byron M
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3020155/
https://www.ncbi.nlm.nih.gov/pubmed/21176166
http://dx.doi.org/10.1186/1757-1146-3-31
_version_ 1782196265768976384
author Romanos, Mary T
Raspovic, Anita
Perrin, Byron M
author_facet Romanos, Mary T
Raspovic, Anita
Perrin, Byron M
author_sort Romanos, Mary T
collection PubMed
description BACKGROUND: The Ankle Brachial Index is a useful clinical test for establishing blood supply to the foot. However, there are limitations to this method when conducted on people with diabetes. As an alternative to the Ankle Brachial Index, measuring Toe Systolic Pressures and the Toe Brachial Index have been recommended to assess the arterial blood supply to the foot. This study aimed to determine the intra and inter-rater reliability of the measurement of Toe Systolic Pressure and the Toe Brachial Index in patients with diabetes using a manual measurement system. METHODS: This was a repeated measures, reliability study. Three raters measured Toe Systolic Pressure and the Toe Brachial Index in thirty participants with diabetes. Measurement sessions occurred on two occasions, one week apart, using a manual photoplethysmography unit (Hadeco Smartdop 45) and a standardised measurement protocol. RESULTS: The mean intra-class correlation for intra-rater reliability for toe systolic pressures was 0.87 (95% LOA: -25.97 to 26.06 mmHg) and the mean intra-class correlation for Toe Brachial Indices was 0.75 (95% LOA: -0.22 to 0.28). The intra-class correlation for inter-rater reliability was 0.88 for toe systolic pressures (95% LOA: -22.91 to 29.17.mmHg) and 0.77 for Toe Brachial Indices (95% LOA: -0.21 to 0.22). CONCLUSION: Despite the reasonable intra-class correlation results, the range of error (95% LOA) was broad. This raises questions regarding the reliability of using a manual sphygmomanometer and PPG for the Toe Systolic Pressure and Toe Brachial Indice.
format Text
id pubmed-3020155
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-30201552011-01-13 The reliability of toe systolic pressure and the toe brachial index in patients with diabetes Romanos, Mary T Raspovic, Anita Perrin, Byron M J Foot Ankle Res Research BACKGROUND: The Ankle Brachial Index is a useful clinical test for establishing blood supply to the foot. However, there are limitations to this method when conducted on people with diabetes. As an alternative to the Ankle Brachial Index, measuring Toe Systolic Pressures and the Toe Brachial Index have been recommended to assess the arterial blood supply to the foot. This study aimed to determine the intra and inter-rater reliability of the measurement of Toe Systolic Pressure and the Toe Brachial Index in patients with diabetes using a manual measurement system. METHODS: This was a repeated measures, reliability study. Three raters measured Toe Systolic Pressure and the Toe Brachial Index in thirty participants with diabetes. Measurement sessions occurred on two occasions, one week apart, using a manual photoplethysmography unit (Hadeco Smartdop 45) and a standardised measurement protocol. RESULTS: The mean intra-class correlation for intra-rater reliability for toe systolic pressures was 0.87 (95% LOA: -25.97 to 26.06 mmHg) and the mean intra-class correlation for Toe Brachial Indices was 0.75 (95% LOA: -0.22 to 0.28). The intra-class correlation for inter-rater reliability was 0.88 for toe systolic pressures (95% LOA: -22.91 to 29.17.mmHg) and 0.77 for Toe Brachial Indices (95% LOA: -0.21 to 0.22). CONCLUSION: Despite the reasonable intra-class correlation results, the range of error (95% LOA) was broad. This raises questions regarding the reliability of using a manual sphygmomanometer and PPG for the Toe Systolic Pressure and Toe Brachial Indice. BioMed Central 2010-12-22 /pmc/articles/PMC3020155/ /pubmed/21176166 http://dx.doi.org/10.1186/1757-1146-3-31 Text en Copyright ©2010 Romanos et al; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (<url>http://creativecommons.org/licenses/by/2.0</url>), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Romanos, Mary T
Raspovic, Anita
Perrin, Byron M
The reliability of toe systolic pressure and the toe brachial index in patients with diabetes
title The reliability of toe systolic pressure and the toe brachial index in patients with diabetes
title_full The reliability of toe systolic pressure and the toe brachial index in patients with diabetes
title_fullStr The reliability of toe systolic pressure and the toe brachial index in patients with diabetes
title_full_unstemmed The reliability of toe systolic pressure and the toe brachial index in patients with diabetes
title_short The reliability of toe systolic pressure and the toe brachial index in patients with diabetes
title_sort reliability of toe systolic pressure and the toe brachial index in patients with diabetes
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3020155/
https://www.ncbi.nlm.nih.gov/pubmed/21176166
http://dx.doi.org/10.1186/1757-1146-3-31
work_keys_str_mv AT romanosmaryt thereliabilityoftoesystolicpressureandthetoebrachialindexinpatientswithdiabetes
AT raspovicanita thereliabilityoftoesystolicpressureandthetoebrachialindexinpatientswithdiabetes
AT perrinbyronm thereliabilityoftoesystolicpressureandthetoebrachialindexinpatientswithdiabetes
AT romanosmaryt reliabilityoftoesystolicpressureandthetoebrachialindexinpatientswithdiabetes
AT raspovicanita reliabilityoftoesystolicpressureandthetoebrachialindexinpatientswithdiabetes
AT perrinbyronm reliabilityoftoesystolicpressureandthetoebrachialindexinpatientswithdiabetes