Cargando…
The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring System
BACKGROUND: Clinical experience with the continuous glucose monitoring systems (CGMS) is limited in Korea. The objective of this study is to evaluate the accuracy of the CGMS and the correlation between interstitial fluid and venous plasma glucose level in Korean healthy male subjects. METHODS: Thir...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Korean Diabetes Association
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3021111/ https://www.ncbi.nlm.nih.gov/pubmed/21246008 http://dx.doi.org/10.4093/kdj.2010.34.6.350 |
_version_ | 1782196347072413696 |
---|---|
author | Baek, Young Ha Jin, Heung Yong Lee, Kyung Ae Kang, Seon Mee Kim, Woong Ji Kim, Min Gul Park, Ji Hyun Chae, Soo Wan Baek, Hong Sun Park, Tae Sun |
author_facet | Baek, Young Ha Jin, Heung Yong Lee, Kyung Ae Kang, Seon Mee Kim, Woong Ji Kim, Min Gul Park, Ji Hyun Chae, Soo Wan Baek, Hong Sun Park, Tae Sun |
author_sort | Baek, Young Ha |
collection | PubMed |
description | BACKGROUND: Clinical experience with the continuous glucose monitoring systems (CGMS) is limited in Korea. The objective of this study is to evaluate the accuracy of the CGMS and the correlation between interstitial fluid and venous plasma glucose level in Korean healthy male subjects. METHODS: Thirty-two subjects were served with glucose solution contained same amount of test food's carbohydrate and test foods after separate overnight fasts. CGMS was performed over 3 days during hopitalization for each subjects. Venous plasma glucose measurements were carried out during 4 hours (0, 0.25, 0.5, 0.75, 1, 2, 4 hours) just before and after glucose solution and test food load. The performance of the CGMS was evaluated by comparing its readings to those obtained at the same time by the hexokinase method using the auto biochemistry machine (Hitachi 7600-110). Also, correlations between glucose recorded with CGMS and venous plasma glucose value were examined. RESULTS: CGMS slightly underestimated the glucose value as compared with the venous plasma glucose level (16.3 ± 22.2 mg/dL). Correlation between CGMS and venous plasma glucose values throughout sensor lifetime is 0.73 (regression analysis: slope = 1.08, intercept = 8.38 mg/dL). Sensor sensitivity can deteriorate over time, with correlations between venous blood glucose and CGMS values dropping from 0.77 during 1st day to 0.65 during 2nd and 3rd day. CONCLUSION: The accuracy of data provided by CGMS may be less than expected. CGMS sensor sensitivity is decreased with the passage of time. But, from this study, CGMS can be used for glucose variability tendency monitoring conveniently to the Korean. |
format | Text |
id | pubmed-3021111 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Korean Diabetes Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-30211112011-01-18 The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring System Baek, Young Ha Jin, Heung Yong Lee, Kyung Ae Kang, Seon Mee Kim, Woong Ji Kim, Min Gul Park, Ji Hyun Chae, Soo Wan Baek, Hong Sun Park, Tae Sun Korean Diabetes J Original Article BACKGROUND: Clinical experience with the continuous glucose monitoring systems (CGMS) is limited in Korea. The objective of this study is to evaluate the accuracy of the CGMS and the correlation between interstitial fluid and venous plasma glucose level in Korean healthy male subjects. METHODS: Thirty-two subjects were served with glucose solution contained same amount of test food's carbohydrate and test foods after separate overnight fasts. CGMS was performed over 3 days during hopitalization for each subjects. Venous plasma glucose measurements were carried out during 4 hours (0, 0.25, 0.5, 0.75, 1, 2, 4 hours) just before and after glucose solution and test food load. The performance of the CGMS was evaluated by comparing its readings to those obtained at the same time by the hexokinase method using the auto biochemistry machine (Hitachi 7600-110). Also, correlations between glucose recorded with CGMS and venous plasma glucose value were examined. RESULTS: CGMS slightly underestimated the glucose value as compared with the venous plasma glucose level (16.3 ± 22.2 mg/dL). Correlation between CGMS and venous plasma glucose values throughout sensor lifetime is 0.73 (regression analysis: slope = 1.08, intercept = 8.38 mg/dL). Sensor sensitivity can deteriorate over time, with correlations between venous blood glucose and CGMS values dropping from 0.77 during 1st day to 0.65 during 2nd and 3rd day. CONCLUSION: The accuracy of data provided by CGMS may be less than expected. CGMS sensor sensitivity is decreased with the passage of time. But, from this study, CGMS can be used for glucose variability tendency monitoring conveniently to the Korean. Korean Diabetes Association 2010-12 2010-12-31 /pmc/articles/PMC3021111/ /pubmed/21246008 http://dx.doi.org/10.4093/kdj.2010.34.6.350 Text en Copyright © 2010 Korean Diabetes Association http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Baek, Young Ha Jin, Heung Yong Lee, Kyung Ae Kang, Seon Mee Kim, Woong Ji Kim, Min Gul Park, Ji Hyun Chae, Soo Wan Baek, Hong Sun Park, Tae Sun The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring System |
title | The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring System |
title_full | The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring System |
title_fullStr | The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring System |
title_full_unstemmed | The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring System |
title_short | The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring System |
title_sort | correlation and accuracy of glucose levels between interstitial fluid and venous plasma by continuous glucose monitoring system |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3021111/ https://www.ncbi.nlm.nih.gov/pubmed/21246008 http://dx.doi.org/10.4093/kdj.2010.34.6.350 |
work_keys_str_mv | AT baekyoungha thecorrelationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem AT jinheungyong thecorrelationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem AT leekyungae thecorrelationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem AT kangseonmee thecorrelationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem AT kimwoongji thecorrelationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem AT kimmingul thecorrelationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem AT parkjihyun thecorrelationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem AT chaesoowan thecorrelationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem AT baekhongsun thecorrelationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem AT parktaesun thecorrelationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem AT baekyoungha correlationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem AT jinheungyong correlationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem AT leekyungae correlationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem AT kangseonmee correlationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem AT kimwoongji correlationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem AT kimmingul correlationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem AT parkjihyun correlationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem AT chaesoowan correlationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem AT baekhongsun correlationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem AT parktaesun correlationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem |