The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring System

BACKGROUND: Clinical experience with the continuous glucose monitoring systems (CGMS) is limited in Korea. The objective of this study is to evaluate the accuracy of the CGMS and the correlation between interstitial fluid and venous plasma glucose level in Korean healthy male subjects. METHODS: Thir...

Descripción completa

Detalles Bibliográficos
Autores principales: Baek, Young Ha, Jin, Heung Yong, Lee, Kyung Ae, Kang, Seon Mee, Kim, Woong Ji, Kim, Min Gul, Park, Ji Hyun, Chae, Soo Wan, Baek, Hong Sun, Park, Tae Sun
Formato: Texto
Lenguaje:English
Publicado: Korean Diabetes Association 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3021111/
https://www.ncbi.nlm.nih.gov/pubmed/21246008
http://dx.doi.org/10.4093/kdj.2010.34.6.350
_version_ 1782196347072413696
author Baek, Young Ha
Jin, Heung Yong
Lee, Kyung Ae
Kang, Seon Mee
Kim, Woong Ji
Kim, Min Gul
Park, Ji Hyun
Chae, Soo Wan
Baek, Hong Sun
Park, Tae Sun
author_facet Baek, Young Ha
Jin, Heung Yong
Lee, Kyung Ae
Kang, Seon Mee
Kim, Woong Ji
Kim, Min Gul
Park, Ji Hyun
Chae, Soo Wan
Baek, Hong Sun
Park, Tae Sun
author_sort Baek, Young Ha
collection PubMed
description BACKGROUND: Clinical experience with the continuous glucose monitoring systems (CGMS) is limited in Korea. The objective of this study is to evaluate the accuracy of the CGMS and the correlation between interstitial fluid and venous plasma glucose level in Korean healthy male subjects. METHODS: Thirty-two subjects were served with glucose solution contained same amount of test food's carbohydrate and test foods after separate overnight fasts. CGMS was performed over 3 days during hopitalization for each subjects. Venous plasma glucose measurements were carried out during 4 hours (0, 0.25, 0.5, 0.75, 1, 2, 4 hours) just before and after glucose solution and test food load. The performance of the CGMS was evaluated by comparing its readings to those obtained at the same time by the hexokinase method using the auto biochemistry machine (Hitachi 7600-110). Also, correlations between glucose recorded with CGMS and venous plasma glucose value were examined. RESULTS: CGMS slightly underestimated the glucose value as compared with the venous plasma glucose level (16.3 ± 22.2 mg/dL). Correlation between CGMS and venous plasma glucose values throughout sensor lifetime is 0.73 (regression analysis: slope = 1.08, intercept = 8.38 mg/dL). Sensor sensitivity can deteriorate over time, with correlations between venous blood glucose and CGMS values dropping from 0.77 during 1st day to 0.65 during 2nd and 3rd day. CONCLUSION: The accuracy of data provided by CGMS may be less than expected. CGMS sensor sensitivity is decreased with the passage of time. But, from this study, CGMS can be used for glucose variability tendency monitoring conveniently to the Korean.
format Text
id pubmed-3021111
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Korean Diabetes Association
record_format MEDLINE/PubMed
spelling pubmed-30211112011-01-18 The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring System Baek, Young Ha Jin, Heung Yong Lee, Kyung Ae Kang, Seon Mee Kim, Woong Ji Kim, Min Gul Park, Ji Hyun Chae, Soo Wan Baek, Hong Sun Park, Tae Sun Korean Diabetes J Original Article BACKGROUND: Clinical experience with the continuous glucose monitoring systems (CGMS) is limited in Korea. The objective of this study is to evaluate the accuracy of the CGMS and the correlation between interstitial fluid and venous plasma glucose level in Korean healthy male subjects. METHODS: Thirty-two subjects were served with glucose solution contained same amount of test food's carbohydrate and test foods after separate overnight fasts. CGMS was performed over 3 days during hopitalization for each subjects. Venous plasma glucose measurements were carried out during 4 hours (0, 0.25, 0.5, 0.75, 1, 2, 4 hours) just before and after glucose solution and test food load. The performance of the CGMS was evaluated by comparing its readings to those obtained at the same time by the hexokinase method using the auto biochemistry machine (Hitachi 7600-110). Also, correlations between glucose recorded with CGMS and venous plasma glucose value were examined. RESULTS: CGMS slightly underestimated the glucose value as compared with the venous plasma glucose level (16.3 ± 22.2 mg/dL). Correlation between CGMS and venous plasma glucose values throughout sensor lifetime is 0.73 (regression analysis: slope = 1.08, intercept = 8.38 mg/dL). Sensor sensitivity can deteriorate over time, with correlations between venous blood glucose and CGMS values dropping from 0.77 during 1st day to 0.65 during 2nd and 3rd day. CONCLUSION: The accuracy of data provided by CGMS may be less than expected. CGMS sensor sensitivity is decreased with the passage of time. But, from this study, CGMS can be used for glucose variability tendency monitoring conveniently to the Korean. Korean Diabetes Association 2010-12 2010-12-31 /pmc/articles/PMC3021111/ /pubmed/21246008 http://dx.doi.org/10.4093/kdj.2010.34.6.350 Text en Copyright © 2010 Korean Diabetes Association http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Baek, Young Ha
Jin, Heung Yong
Lee, Kyung Ae
Kang, Seon Mee
Kim, Woong Ji
Kim, Min Gul
Park, Ji Hyun
Chae, Soo Wan
Baek, Hong Sun
Park, Tae Sun
The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring System
title The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring System
title_full The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring System
title_fullStr The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring System
title_full_unstemmed The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring System
title_short The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring System
title_sort correlation and accuracy of glucose levels between interstitial fluid and venous plasma by continuous glucose monitoring system
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3021111/
https://www.ncbi.nlm.nih.gov/pubmed/21246008
http://dx.doi.org/10.4093/kdj.2010.34.6.350
work_keys_str_mv AT baekyoungha thecorrelationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem
AT jinheungyong thecorrelationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem
AT leekyungae thecorrelationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem
AT kangseonmee thecorrelationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem
AT kimwoongji thecorrelationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem
AT kimmingul thecorrelationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem
AT parkjihyun thecorrelationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem
AT chaesoowan thecorrelationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem
AT baekhongsun thecorrelationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem
AT parktaesun thecorrelationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem
AT baekyoungha correlationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem
AT jinheungyong correlationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem
AT leekyungae correlationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem
AT kangseonmee correlationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem
AT kimwoongji correlationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem
AT kimmingul correlationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem
AT parkjihyun correlationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem
AT chaesoowan correlationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem
AT baekhongsun correlationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem
AT parktaesun correlationandaccuracyofglucoselevelsbetweeninterstitialfluidandvenousplasmabycontinuousglucosemonitoringsystem