Cystic Duct Closure by Sealing With Bipolar Electrocoagulation

BACKGROUND: Cystic duct leakage after cholecystectomy is not uncommon and is a potentially serious complication. The aim of this study was to assess a bipolar sealing system (LigaSure(®)) for closure of the cystic duct. METHODS: The records from consecutive laparoscopic cholecystectomies performed i...

Descripción completa

Detalles Bibliográficos
Autores principales: Schulze, S., Damgaard, B., Jorgensen, L. N., Larsen, S. S., Kristiansen, V. B.
Formato: Texto
Lenguaje:English
Publicado: Society of Laparoendoscopic Surgeons 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3021292/
https://www.ncbi.nlm.nih.gov/pubmed/20412641
http://dx.doi.org/10.4293/108680810X12674612014347
_version_ 1782196364061442048
author Schulze, S.
Damgaard, B.
Jorgensen, L. N.
Larsen, S. S.
Kristiansen, V. B.
author_facet Schulze, S.
Damgaard, B.
Jorgensen, L. N.
Larsen, S. S.
Kristiansen, V. B.
author_sort Schulze, S.
collection PubMed
description BACKGROUND: Cystic duct leakage after cholecystectomy is not uncommon and is a potentially serious complication. The aim of this study was to assess a bipolar sealing system (LigaSure(®)) for closure of the cystic duct. METHODS: The records from consecutive laparoscopic cholecystectomies performed in 2 hospitals with closure of the cystic duct with LigaSure after informed consent were recorded and complications and morbidity registered. The records were compared with those of patients undergoing laparoscopic cholecystectomy with closure of the cystic duct with clips during the same period. RESULTS: During the study period, 218 laparoscopic cholecystectomies were performed; 102 of these were performed with the LigaSure. One patient was excluded due to violation of the protocol. We experienced no cases of cystic duct leakage, but in one patient, bile leakage from the gallbladder bed was observed probably due to a small aberrant duct. CONCLUSION: The LigaSure system was safe and effective for closure and division of the cystic duct in laparoscopic cholecystectomy.
format Text
id pubmed-3021292
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Society of Laparoendoscopic Surgeons
record_format MEDLINE/PubMed
spelling pubmed-30212922011-02-17 Cystic Duct Closure by Sealing With Bipolar Electrocoagulation Schulze, S. Damgaard, B. Jorgensen, L. N. Larsen, S. S. Kristiansen, V. B. JSLS Scientific Papers BACKGROUND: Cystic duct leakage after cholecystectomy is not uncommon and is a potentially serious complication. The aim of this study was to assess a bipolar sealing system (LigaSure(®)) for closure of the cystic duct. METHODS: The records from consecutive laparoscopic cholecystectomies performed in 2 hospitals with closure of the cystic duct with LigaSure after informed consent were recorded and complications and morbidity registered. The records were compared with those of patients undergoing laparoscopic cholecystectomy with closure of the cystic duct with clips during the same period. RESULTS: During the study period, 218 laparoscopic cholecystectomies were performed; 102 of these were performed with the LigaSure. One patient was excluded due to violation of the protocol. We experienced no cases of cystic duct leakage, but in one patient, bile leakage from the gallbladder bed was observed probably due to a small aberrant duct. CONCLUSION: The LigaSure system was safe and effective for closure and division of the cystic duct in laparoscopic cholecystectomy. Society of Laparoendoscopic Surgeons 2010 /pmc/articles/PMC3021292/ /pubmed/20412641 http://dx.doi.org/10.4293/108680810X12674612014347 Text en © 2010 by JSLS, Journal of the Society of Laparoendoscopic Surgeons. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits for noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited and is not altered in any way.
spellingShingle Scientific Papers
Schulze, S.
Damgaard, B.
Jorgensen, L. N.
Larsen, S. S.
Kristiansen, V. B.
Cystic Duct Closure by Sealing With Bipolar Electrocoagulation
title Cystic Duct Closure by Sealing With Bipolar Electrocoagulation
title_full Cystic Duct Closure by Sealing With Bipolar Electrocoagulation
title_fullStr Cystic Duct Closure by Sealing With Bipolar Electrocoagulation
title_full_unstemmed Cystic Duct Closure by Sealing With Bipolar Electrocoagulation
title_short Cystic Duct Closure by Sealing With Bipolar Electrocoagulation
title_sort cystic duct closure by sealing with bipolar electrocoagulation
topic Scientific Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3021292/
https://www.ncbi.nlm.nih.gov/pubmed/20412641
http://dx.doi.org/10.4293/108680810X12674612014347
work_keys_str_mv AT schulzes cysticductclosurebysealingwithbipolarelectrocoagulation
AT damgaardb cysticductclosurebysealingwithbipolarelectrocoagulation
AT jorgensenln cysticductclosurebysealingwithbipolarelectrocoagulation
AT larsenss cysticductclosurebysealingwithbipolarelectrocoagulation
AT kristiansenvb cysticductclosurebysealingwithbipolarelectrocoagulation