Cargando…
Cystic Duct Closure by Sealing With Bipolar Electrocoagulation
BACKGROUND: Cystic duct leakage after cholecystectomy is not uncommon and is a potentially serious complication. The aim of this study was to assess a bipolar sealing system (LigaSure(®)) for closure of the cystic duct. METHODS: The records from consecutive laparoscopic cholecystectomies performed i...
Autores principales: | , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Society of Laparoendoscopic Surgeons
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3021292/ https://www.ncbi.nlm.nih.gov/pubmed/20412641 http://dx.doi.org/10.4293/108680810X12674612014347 |
_version_ | 1782196364061442048 |
---|---|
author | Schulze, S. Damgaard, B. Jorgensen, L. N. Larsen, S. S. Kristiansen, V. B. |
author_facet | Schulze, S. Damgaard, B. Jorgensen, L. N. Larsen, S. S. Kristiansen, V. B. |
author_sort | Schulze, S. |
collection | PubMed |
description | BACKGROUND: Cystic duct leakage after cholecystectomy is not uncommon and is a potentially serious complication. The aim of this study was to assess a bipolar sealing system (LigaSure(®)) for closure of the cystic duct. METHODS: The records from consecutive laparoscopic cholecystectomies performed in 2 hospitals with closure of the cystic duct with LigaSure after informed consent were recorded and complications and morbidity registered. The records were compared with those of patients undergoing laparoscopic cholecystectomy with closure of the cystic duct with clips during the same period. RESULTS: During the study period, 218 laparoscopic cholecystectomies were performed; 102 of these were performed with the LigaSure. One patient was excluded due to violation of the protocol. We experienced no cases of cystic duct leakage, but in one patient, bile leakage from the gallbladder bed was observed probably due to a small aberrant duct. CONCLUSION: The LigaSure system was safe and effective for closure and division of the cystic duct in laparoscopic cholecystectomy. |
format | Text |
id | pubmed-3021292 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Society of Laparoendoscopic Surgeons |
record_format | MEDLINE/PubMed |
spelling | pubmed-30212922011-02-17 Cystic Duct Closure by Sealing With Bipolar Electrocoagulation Schulze, S. Damgaard, B. Jorgensen, L. N. Larsen, S. S. Kristiansen, V. B. JSLS Scientific Papers BACKGROUND: Cystic duct leakage after cholecystectomy is not uncommon and is a potentially serious complication. The aim of this study was to assess a bipolar sealing system (LigaSure(®)) for closure of the cystic duct. METHODS: The records from consecutive laparoscopic cholecystectomies performed in 2 hospitals with closure of the cystic duct with LigaSure after informed consent were recorded and complications and morbidity registered. The records were compared with those of patients undergoing laparoscopic cholecystectomy with closure of the cystic duct with clips during the same period. RESULTS: During the study period, 218 laparoscopic cholecystectomies were performed; 102 of these were performed with the LigaSure. One patient was excluded due to violation of the protocol. We experienced no cases of cystic duct leakage, but in one patient, bile leakage from the gallbladder bed was observed probably due to a small aberrant duct. CONCLUSION: The LigaSure system was safe and effective for closure and division of the cystic duct in laparoscopic cholecystectomy. Society of Laparoendoscopic Surgeons 2010 /pmc/articles/PMC3021292/ /pubmed/20412641 http://dx.doi.org/10.4293/108680810X12674612014347 Text en © 2010 by JSLS, Journal of the Society of Laparoendoscopic Surgeons. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits for noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited and is not altered in any way. |
spellingShingle | Scientific Papers Schulze, S. Damgaard, B. Jorgensen, L. N. Larsen, S. S. Kristiansen, V. B. Cystic Duct Closure by Sealing With Bipolar Electrocoagulation |
title | Cystic Duct Closure by Sealing With Bipolar Electrocoagulation |
title_full | Cystic Duct Closure by Sealing With Bipolar Electrocoagulation |
title_fullStr | Cystic Duct Closure by Sealing With Bipolar Electrocoagulation |
title_full_unstemmed | Cystic Duct Closure by Sealing With Bipolar Electrocoagulation |
title_short | Cystic Duct Closure by Sealing With Bipolar Electrocoagulation |
title_sort | cystic duct closure by sealing with bipolar electrocoagulation |
topic | Scientific Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3021292/ https://www.ncbi.nlm.nih.gov/pubmed/20412641 http://dx.doi.org/10.4293/108680810X12674612014347 |
work_keys_str_mv | AT schulzes cysticductclosurebysealingwithbipolarelectrocoagulation AT damgaardb cysticductclosurebysealingwithbipolarelectrocoagulation AT jorgensenln cysticductclosurebysealingwithbipolarelectrocoagulation AT larsenss cysticductclosurebysealingwithbipolarelectrocoagulation AT kristiansenvb cysticductclosurebysealingwithbipolarelectrocoagulation |