Cystic Duct Closure by Sealing With Bipolar Electrocoagulation
BACKGROUND: Cystic duct leakage after cholecystectomy is not uncommon and is a potentially serious complication. The aim of this study was to assess a bipolar sealing system (LigaSure(®)) for closure of the cystic duct. METHODS: The records from consecutive laparoscopic cholecystectomies performed i...
Autores principales: | Schulze, S., Damgaard, B., Jorgensen, L. N., Larsen, S. S., Kristiansen, V. B. |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Society of Laparoendoscopic Surgeons
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3021292/ https://www.ncbi.nlm.nih.gov/pubmed/20412641 http://dx.doi.org/10.4293/108680810X12674612014347 |