Suboptimal Performance of Blood Glucose Meters in an Antenatal Diabetes Clinic
OBJECTIVE: The objective of this study was to evaluate the performance of blood glucose meters in diabetes associated with pregnancy (DP). RESEARCH DESIGN AND METHODS: Finger-prick blood glucose levels measured using six different glucose meters on 102 patients with DP attending an antenatal clinic...
Autores principales: | , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
American Diabetes Association
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3024344/ https://www.ncbi.nlm.nih.gov/pubmed/21216849 http://dx.doi.org/10.2337/dc10-1457 |
_version_ | 1782196767895322624 |
---|---|
author | Perera, Nimalie Jacintha Molyneaux, Lynda Constantino, Maria Ines McGill, Marg Yue, Dennis Koon-See Twigg, Stephen Morris Ross, Glynis Pauline |
author_facet | Perera, Nimalie Jacintha Molyneaux, Lynda Constantino, Maria Ines McGill, Marg Yue, Dennis Koon-See Twigg, Stephen Morris Ross, Glynis Pauline |
author_sort | Perera, Nimalie Jacintha |
collection | PubMed |
description | OBJECTIVE: The objective of this study was to evaluate the performance of blood glucose meters in diabetes associated with pregnancy (DP). RESEARCH DESIGN AND METHODS: Finger-prick blood glucose levels measured using six different glucose meters on 102 patients with DP attending an antenatal clinic were compared with laboratory plasma glucose results. HbA(1c) and hematocrit were also measured. RESULTS: The plasma glucose range was 2.2–9.4 mmol/L with hematocrit 33–37% and mean HbA(1c) 5.5% ± 0.56 (SD). All meters provided plasma equivalent results except one, which reported whole blood glucose that was adjusted to plasma equivalent values. The absolute glucose difference [meter − plasma glucose] was 0.232 ± 0.69 to 0.725 ± 0.62 mmol/L mean ± SD and bias ranged from 6.1 to 15.8%. Two meters were affected by hematocrit <36% (P < 0.05). CONCLUSIONS: Blood glucose meters in current use are not optimally accurate when compared with plasma glucose measurement in DP. Recognition of this deviation is essential to prevent inappropriate treatment of DP. |
format | Text |
id | pubmed-3024344 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | American Diabetes Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-30243442012-02-01 Suboptimal Performance of Blood Glucose Meters in an Antenatal Diabetes Clinic Perera, Nimalie Jacintha Molyneaux, Lynda Constantino, Maria Ines McGill, Marg Yue, Dennis Koon-See Twigg, Stephen Morris Ross, Glynis Pauline Diabetes Care Original Research OBJECTIVE: The objective of this study was to evaluate the performance of blood glucose meters in diabetes associated with pregnancy (DP). RESEARCH DESIGN AND METHODS: Finger-prick blood glucose levels measured using six different glucose meters on 102 patients with DP attending an antenatal clinic were compared with laboratory plasma glucose results. HbA(1c) and hematocrit were also measured. RESULTS: The plasma glucose range was 2.2–9.4 mmol/L with hematocrit 33–37% and mean HbA(1c) 5.5% ± 0.56 (SD). All meters provided plasma equivalent results except one, which reported whole blood glucose that was adjusted to plasma equivalent values. The absolute glucose difference [meter − plasma glucose] was 0.232 ± 0.69 to 0.725 ± 0.62 mmol/L mean ± SD and bias ranged from 6.1 to 15.8%. Two meters were affected by hematocrit <36% (P < 0.05). CONCLUSIONS: Blood glucose meters in current use are not optimally accurate when compared with plasma glucose measurement in DP. Recognition of this deviation is essential to prevent inappropriate treatment of DP. American Diabetes Association 2011-02 2011-01-20 /pmc/articles/PMC3024344/ /pubmed/21216849 http://dx.doi.org/10.2337/dc10-1457 Text en © 2011 by the American Diabetes Association. Readers may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered. See http://creativecommons.org/licenses/by-nc-nd/3.0/ for details. |
spellingShingle | Original Research Perera, Nimalie Jacintha Molyneaux, Lynda Constantino, Maria Ines McGill, Marg Yue, Dennis Koon-See Twigg, Stephen Morris Ross, Glynis Pauline Suboptimal Performance of Blood Glucose Meters in an Antenatal Diabetes Clinic |
title | Suboptimal Performance of Blood Glucose Meters in an Antenatal Diabetes Clinic |
title_full | Suboptimal Performance of Blood Glucose Meters in an Antenatal Diabetes Clinic |
title_fullStr | Suboptimal Performance of Blood Glucose Meters in an Antenatal Diabetes Clinic |
title_full_unstemmed | Suboptimal Performance of Blood Glucose Meters in an Antenatal Diabetes Clinic |
title_short | Suboptimal Performance of Blood Glucose Meters in an Antenatal Diabetes Clinic |
title_sort | suboptimal performance of blood glucose meters in an antenatal diabetes clinic |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3024344/ https://www.ncbi.nlm.nih.gov/pubmed/21216849 http://dx.doi.org/10.2337/dc10-1457 |
work_keys_str_mv | AT pereranimaliejacintha suboptimalperformanceofbloodglucosemetersinanantenataldiabetesclinic AT molyneauxlynda suboptimalperformanceofbloodglucosemetersinanantenataldiabetesclinic AT constantinomariaines suboptimalperformanceofbloodglucosemetersinanantenataldiabetesclinic AT mcgillmarg suboptimalperformanceofbloodglucosemetersinanantenataldiabetesclinic AT yuedenniskoonsee suboptimalperformanceofbloodglucosemetersinanantenataldiabetesclinic AT twiggstephenmorris suboptimalperformanceofbloodglucosemetersinanantenataldiabetesclinic AT rossglynispauline suboptimalperformanceofbloodglucosemetersinanantenataldiabetesclinic |