Cargando…
A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables
PURPOSE: The aim of this study was to investigate a comparison of implant bone bed preparation with Er,Cr:YSGG laser and conventional drills on the relationship between implant stability quotient (ISQ) values and implant insertion variables. MATERIALS AND METHODS: Forty implants were inserted into t...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Prosthodontics
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3024505/ https://www.ncbi.nlm.nih.gov/pubmed/21264194 http://dx.doi.org/10.4047/jap.2010.2.4.148 |
_version_ | 1782196798070194176 |
---|---|
author | Lee, Su-Young Piao, Chunmei Heo, Seong-Joo Koak, Jai-Young Lee, Joo-Hee Kim, Tae-Hyung Kim, Myung-Joo Kwon, Ho-Beom Kim, Seong-Kyun |
author_facet | Lee, Su-Young Piao, Chunmei Heo, Seong-Joo Koak, Jai-Young Lee, Joo-Hee Kim, Tae-Hyung Kim, Myung-Joo Kwon, Ho-Beom Kim, Seong-Kyun |
author_sort | Lee, Su-Young |
collection | PubMed |
description | PURPOSE: The aim of this study was to investigate a comparison of implant bone bed preparation with Er,Cr:YSGG laser and conventional drills on the relationship between implant stability quotient (ISQ) values and implant insertion variables. MATERIALS AND METHODS: Forty implants were inserted into two different types of pig rib bone. One group was prepared with conventional drills and a total of 20 implants were inserted into type I and type II bone. The other group was prepared with a Er,Cr:YSGG laser and a total of 20 implants were inserted into type I and type II bone. ISQ, maximum insertion torque, angular momentum, and insertion torque energy values were measured. RESULTS: The mean values for variables were significantly higher in type I bone than in type II bone (P < .01). In type I bone, the ISQ values in the drill group were significantly higher than in the laser group (P < .05). In type II bone, the ISQ values in the laser group were significantly higher than in the drill group (P < .01). In both type I and type II bone, the maximum insertion torque, total energy, and total angular momentum values between the drill and laser groups did not differ significantly (P ≥ .05). The ISQ values were correlated with maximum insertion torque (P < .01, r = .731), total energy (P < .01, r = .696), and angular momentum (P < .01, r = .696). CONCLUSION: Within the limitations of this study, the effects of bone bed preparation with Er,Cr:YSGG laser on the relationship between implant stability quotient (ISQ) values and implant insertion variables were comparable to those of drilling. |
format | Text |
id | pubmed-3024505 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | The Korean Academy of Prosthodontics |
record_format | MEDLINE/PubMed |
spelling | pubmed-30245052011-01-24 A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables Lee, Su-Young Piao, Chunmei Heo, Seong-Joo Koak, Jai-Young Lee, Joo-Hee Kim, Tae-Hyung Kim, Myung-Joo Kwon, Ho-Beom Kim, Seong-Kyun J Adv Prosthodont Original Article PURPOSE: The aim of this study was to investigate a comparison of implant bone bed preparation with Er,Cr:YSGG laser and conventional drills on the relationship between implant stability quotient (ISQ) values and implant insertion variables. MATERIALS AND METHODS: Forty implants were inserted into two different types of pig rib bone. One group was prepared with conventional drills and a total of 20 implants were inserted into type I and type II bone. The other group was prepared with a Er,Cr:YSGG laser and a total of 20 implants were inserted into type I and type II bone. ISQ, maximum insertion torque, angular momentum, and insertion torque energy values were measured. RESULTS: The mean values for variables were significantly higher in type I bone than in type II bone (P < .01). In type I bone, the ISQ values in the drill group were significantly higher than in the laser group (P < .05). In type II bone, the ISQ values in the laser group were significantly higher than in the drill group (P < .01). In both type I and type II bone, the maximum insertion torque, total energy, and total angular momentum values between the drill and laser groups did not differ significantly (P ≥ .05). The ISQ values were correlated with maximum insertion torque (P < .01, r = .731), total energy (P < .01, r = .696), and angular momentum (P < .01, r = .696). CONCLUSION: Within the limitations of this study, the effects of bone bed preparation with Er,Cr:YSGG laser on the relationship between implant stability quotient (ISQ) values and implant insertion variables were comparable to those of drilling. The Korean Academy of Prosthodontics 2010-12 2010-12-31 /pmc/articles/PMC3024505/ /pubmed/21264194 http://dx.doi.org/10.4047/jap.2010.2.4.148 Text en © 2010 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Su-Young Piao, Chunmei Heo, Seong-Joo Koak, Jai-Young Lee, Joo-Hee Kim, Tae-Hyung Kim, Myung-Joo Kwon, Ho-Beom Kim, Seong-Kyun A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables |
title | A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables |
title_full | A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables |
title_fullStr | A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables |
title_full_unstemmed | A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables |
title_short | A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables |
title_sort | comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (isq) values and implant insertion variables |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3024505/ https://www.ncbi.nlm.nih.gov/pubmed/21264194 http://dx.doi.org/10.4047/jap.2010.2.4.148 |
work_keys_str_mv | AT leesuyoung acomparisonofbonebedpreparationwithlaserandconventionaldrillontherelationshipbetweenimplantstabilityquotientisqvaluesandimplantinsertionvariables AT piaochunmei acomparisonofbonebedpreparationwithlaserandconventionaldrillontherelationshipbetweenimplantstabilityquotientisqvaluesandimplantinsertionvariables AT heoseongjoo acomparisonofbonebedpreparationwithlaserandconventionaldrillontherelationshipbetweenimplantstabilityquotientisqvaluesandimplantinsertionvariables AT koakjaiyoung acomparisonofbonebedpreparationwithlaserandconventionaldrillontherelationshipbetweenimplantstabilityquotientisqvaluesandimplantinsertionvariables AT leejoohee acomparisonofbonebedpreparationwithlaserandconventionaldrillontherelationshipbetweenimplantstabilityquotientisqvaluesandimplantinsertionvariables AT kimtaehyung acomparisonofbonebedpreparationwithlaserandconventionaldrillontherelationshipbetweenimplantstabilityquotientisqvaluesandimplantinsertionvariables AT kimmyungjoo acomparisonofbonebedpreparationwithlaserandconventionaldrillontherelationshipbetweenimplantstabilityquotientisqvaluesandimplantinsertionvariables AT kwonhobeom acomparisonofbonebedpreparationwithlaserandconventionaldrillontherelationshipbetweenimplantstabilityquotientisqvaluesandimplantinsertionvariables AT kimseongkyun acomparisonofbonebedpreparationwithlaserandconventionaldrillontherelationshipbetweenimplantstabilityquotientisqvaluesandimplantinsertionvariables AT leesuyoung comparisonofbonebedpreparationwithlaserandconventionaldrillontherelationshipbetweenimplantstabilityquotientisqvaluesandimplantinsertionvariables AT piaochunmei comparisonofbonebedpreparationwithlaserandconventionaldrillontherelationshipbetweenimplantstabilityquotientisqvaluesandimplantinsertionvariables AT heoseongjoo comparisonofbonebedpreparationwithlaserandconventionaldrillontherelationshipbetweenimplantstabilityquotientisqvaluesandimplantinsertionvariables AT koakjaiyoung comparisonofbonebedpreparationwithlaserandconventionaldrillontherelationshipbetweenimplantstabilityquotientisqvaluesandimplantinsertionvariables AT leejoohee comparisonofbonebedpreparationwithlaserandconventionaldrillontherelationshipbetweenimplantstabilityquotientisqvaluesandimplantinsertionvariables AT kimtaehyung comparisonofbonebedpreparationwithlaserandconventionaldrillontherelationshipbetweenimplantstabilityquotientisqvaluesandimplantinsertionvariables AT kimmyungjoo comparisonofbonebedpreparationwithlaserandconventionaldrillontherelationshipbetweenimplantstabilityquotientisqvaluesandimplantinsertionvariables AT kwonhobeom comparisonofbonebedpreparationwithlaserandconventionaldrillontherelationshipbetweenimplantstabilityquotientisqvaluesandimplantinsertionvariables AT kimseongkyun comparisonofbonebedpreparationwithlaserandconventionaldrillontherelationshipbetweenimplantstabilityquotientisqvaluesandimplantinsertionvariables |