A fetal scalp electrode as a simple aid in the search for a lost needle fragment during sacrospinous ligament fixation
A needle fragment was lost during a sacrospinous ligament fixation. This was recognized during the procedure, but could not be found at that moment. The patient complained of severe buttock pain postoperatively. The needle fragment was localized on CT scan of the pelvis. A fetal scalp electrode help...
Autores principales: | , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Springer-Verlag
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3025122/ https://www.ncbi.nlm.nih.gov/pubmed/20798923 http://dx.doi.org/10.1007/s00192-010-1247-5 |
_version_ | 1782196876130385920 |
---|---|
author | Schoonenberg, Marieke P. G. Kluivers, Kirsten B. Vierhout, Mark E. |
author_facet | Schoonenberg, Marieke P. G. Kluivers, Kirsten B. Vierhout, Mark E. |
author_sort | Schoonenberg, Marieke P. G. |
collection | PubMed |
description | A needle fragment was lost during a sacrospinous ligament fixation. This was recognized during the procedure, but could not be found at that moment. The patient complained of severe buttock pain postoperatively. The needle fragment was localized on CT scan of the pelvis. A fetal scalp electrode helped as a search device to localize the needle on X-ray during the secondary surgery. The patient was operated successfully and was free of pain after 6 weeks. |
format | Text |
id | pubmed-3025122 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Springer-Verlag |
record_format | MEDLINE/PubMed |
spelling | pubmed-30251222011-02-22 A fetal scalp electrode as a simple aid in the search for a lost needle fragment during sacrospinous ligament fixation Schoonenberg, Marieke P. G. Kluivers, Kirsten B. Vierhout, Mark E. Int Urogynecol J Case Report A needle fragment was lost during a sacrospinous ligament fixation. This was recognized during the procedure, but could not be found at that moment. The patient complained of severe buttock pain postoperatively. The needle fragment was localized on CT scan of the pelvis. A fetal scalp electrode helped as a search device to localize the needle on X-ray during the secondary surgery. The patient was operated successfully and was free of pain after 6 weeks. Springer-Verlag 2010-08-27 2011 /pmc/articles/PMC3025122/ /pubmed/20798923 http://dx.doi.org/10.1007/s00192-010-1247-5 Text en © The Author(s) 2010 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited. |
spellingShingle | Case Report Schoonenberg, Marieke P. G. Kluivers, Kirsten B. Vierhout, Mark E. A fetal scalp electrode as a simple aid in the search for a lost needle fragment during sacrospinous ligament fixation |
title | A fetal scalp electrode as a simple aid in the search for a lost needle fragment during sacrospinous ligament fixation |
title_full | A fetal scalp electrode as a simple aid in the search for a lost needle fragment during sacrospinous ligament fixation |
title_fullStr | A fetal scalp electrode as a simple aid in the search for a lost needle fragment during sacrospinous ligament fixation |
title_full_unstemmed | A fetal scalp electrode as a simple aid in the search for a lost needle fragment during sacrospinous ligament fixation |
title_short | A fetal scalp electrode as a simple aid in the search for a lost needle fragment during sacrospinous ligament fixation |
title_sort | fetal scalp electrode as a simple aid in the search for a lost needle fragment during sacrospinous ligament fixation |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3025122/ https://www.ncbi.nlm.nih.gov/pubmed/20798923 http://dx.doi.org/10.1007/s00192-010-1247-5 |
work_keys_str_mv | AT schoonenbergmariekepg afetalscalpelectrodeasasimpleaidinthesearchforalostneedlefragmentduringsacrospinousligamentfixation AT kluiverskirstenb afetalscalpelectrodeasasimpleaidinthesearchforalostneedlefragmentduringsacrospinousligamentfixation AT vierhoutmarke afetalscalpelectrodeasasimpleaidinthesearchforalostneedlefragmentduringsacrospinousligamentfixation AT schoonenbergmariekepg fetalscalpelectrodeasasimpleaidinthesearchforalostneedlefragmentduringsacrospinousligamentfixation AT kluiverskirstenb fetalscalpelectrodeasasimpleaidinthesearchforalostneedlefragmentduringsacrospinousligamentfixation AT vierhoutmarke fetalscalpelectrodeasasimpleaidinthesearchforalostneedlefragmentduringsacrospinousligamentfixation |