Cargando…

Awake Glidescope® intubation in a patient with a huge and fixed supraglottic mass -A case report-

Intubating patients with a huge, fixed supraglottic mass causing an obstruction of the glottis is difficult to most anesthesiologists. We attempted awake fiberoptic orotracheal intubation assisted by Glidescope® Videolaryngoscope (GVL) following topical anesthesia with 4% lidocaine spray and remifen...

Descripción completa

Detalles Bibliográficos
Autores principales: Choi, Guen Seok, Park, Sang Il, Lee, Eun Ha, Yoon, Seok Hwa
Formato: Texto
Lenguaje:English
Publicado: The Korean Society of Anesthesiologists 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3030048/
https://www.ncbi.nlm.nih.gov/pubmed/21286452
http://dx.doi.org/10.4097/kjae.2010.59.S.S26
_version_ 1782197254452412416
author Choi, Guen Seok
Park, Sang Il
Lee, Eun Ha
Yoon, Seok Hwa
author_facet Choi, Guen Seok
Park, Sang Il
Lee, Eun Ha
Yoon, Seok Hwa
author_sort Choi, Guen Seok
collection PubMed
description Intubating patients with a huge, fixed supraglottic mass causing an obstruction of the glottis is difficult to most anesthesiologists. We attempted awake fiberoptic orotracheal intubation assisted by Glidescope® Videolaryngoscope (GVL) following topical anesthesia with 4% lidocaine spray and remifentanil infusion. The glottis could not be identified by the GVL view. However, by entering toward the right side of the mass with bronchoscope, the glottis was found. Due to stiffness of the mass, we were unable to further enter the area using the bronchoscope. Alternatively, we attempted to expose the glottis by GVL blade and then successfully intubated the patient by manually pressing the cricoids cartilage. GVL is nonetheless an excellent instrument in airway management compared to fiberoptic bronchoscope for patients with a huge and fixed supraglottic mass.
format Text
id pubmed-3030048
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher The Korean Society of Anesthesiologists
record_format MEDLINE/PubMed
spelling pubmed-30300482011-01-31 Awake Glidescope® intubation in a patient with a huge and fixed supraglottic mass -A case report- Choi, Guen Seok Park, Sang Il Lee, Eun Ha Yoon, Seok Hwa Korean J Anesthesiol Case Report Intubating patients with a huge, fixed supraglottic mass causing an obstruction of the glottis is difficult to most anesthesiologists. We attempted awake fiberoptic orotracheal intubation assisted by Glidescope® Videolaryngoscope (GVL) following topical anesthesia with 4% lidocaine spray and remifentanil infusion. The glottis could not be identified by the GVL view. However, by entering toward the right side of the mass with bronchoscope, the glottis was found. Due to stiffness of the mass, we were unable to further enter the area using the bronchoscope. Alternatively, we attempted to expose the glottis by GVL blade and then successfully intubated the patient by manually pressing the cricoids cartilage. GVL is nonetheless an excellent instrument in airway management compared to fiberoptic bronchoscope for patients with a huge and fixed supraglottic mass. The Korean Society of Anesthesiologists 2010-12 2010-12-31 /pmc/articles/PMC3030048/ /pubmed/21286452 http://dx.doi.org/10.4097/kjae.2010.59.S.S26 Text en Copyright © The Korean Society of Anesthesiologists, 2010 http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Choi, Guen Seok
Park, Sang Il
Lee, Eun Ha
Yoon, Seok Hwa
Awake Glidescope® intubation in a patient with a huge and fixed supraglottic mass -A case report-
title Awake Glidescope® intubation in a patient with a huge and fixed supraglottic mass -A case report-
title_full Awake Glidescope® intubation in a patient with a huge and fixed supraglottic mass -A case report-
title_fullStr Awake Glidescope® intubation in a patient with a huge and fixed supraglottic mass -A case report-
title_full_unstemmed Awake Glidescope® intubation in a patient with a huge and fixed supraglottic mass -A case report-
title_short Awake Glidescope® intubation in a patient with a huge and fixed supraglottic mass -A case report-
title_sort awake glidescope® intubation in a patient with a huge and fixed supraglottic mass -a case report-
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3030048/
https://www.ncbi.nlm.nih.gov/pubmed/21286452
http://dx.doi.org/10.4097/kjae.2010.59.S.S26
work_keys_str_mv AT choiguenseok awakeglidescopeintubationinapatientwithahugeandfixedsupraglotticmassacasereport
AT parksangil awakeglidescopeintubationinapatientwithahugeandfixedsupraglotticmassacasereport
AT leeeunha awakeglidescopeintubationinapatientwithahugeandfixedsupraglotticmassacasereport
AT yoonseokhwa awakeglidescopeintubationinapatientwithahugeandfixedsupraglotticmassacasereport