Implementation of a new cost efficacy method for blood irradiation using a non dedicated device

OBJECTIVES: To implement a new cost efficacy internal Service for blood component irradiation, we carried out specific procedures and quality assurance reports using the linear accelerators (LINACs) of the Regina Elena Institute (IRE) Radiotherapy Department instead of a dedicated device. METHODS: T...

Descripción completa

Detalles Bibliográficos
Autores principales: Pinnarò, Paola, Soriani, Antonella, D'Alessio, Daniela, Giordano, Carolina, Foddai, Maria Laura, Pinzi, Valentina, Strigari, Lidia
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3031252/
https://www.ncbi.nlm.nih.gov/pubmed/21226943
http://dx.doi.org/10.1186/1756-9966-30-7
_version_ 1782197335678255104
author Pinnarò, Paola
Soriani, Antonella
D'Alessio, Daniela
Giordano, Carolina
Foddai, Maria Laura
Pinzi, Valentina
Strigari, Lidia
author_facet Pinnarò, Paola
Soriani, Antonella
D'Alessio, Daniela
Giordano, Carolina
Foddai, Maria Laura
Pinzi, Valentina
Strigari, Lidia
author_sort Pinnarò, Paola
collection PubMed
description OBJECTIVES: To implement a new cost efficacy internal Service for blood component irradiation, we carried out specific procedures and quality assurance reports using the linear accelerators (LINACs) of the Regina Elena Institute (IRE) Radiotherapy Department instead of a dedicated device. METHODS: The technical aspects, quality assurance and regulatory requirements of the internal procedure to set up a local irradiated blood bank have been defined. The LINACs of the IRE Radiotherapy Department were used to deliver a mean dose of 32 Gy and dose accuracy was checked with gafchromic film. The overall time/cost of this procedure was compared with the previous procedure, out-sourcing the irradiation of blood components. RESULTS: A total of 1996 blood component units were internally irradiated in the first year. Moreover, reducing the overall procedure time by a third. Overall cost/bag of external and internal procedures was approx. 66 € and 11 €, respectively. Thus the average saving of cost/bag was higher than 80%. The use of gafchromic films in all irradiated blood component bags allowed the accuracy of the dose delivered to blood to be checked. CONCLUSIONS: By utilizing LINACs installed in the Radiotherapy Department it is possible to provide an internal blood component irradiation service, capitalizing on internal resources without any inconvenience/discomfort to patients undergoing radiotherapy and satisfying governmental regulatory requirements. The internal irradiation procedures has proven to be safe and feasible, and along with the significant cost/time reduction suggests that it is more advantageous than external procedures.
format Text
id pubmed-3031252
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-30312522011-02-01 Implementation of a new cost efficacy method for blood irradiation using a non dedicated device Pinnarò, Paola Soriani, Antonella D'Alessio, Daniela Giordano, Carolina Foddai, Maria Laura Pinzi, Valentina Strigari, Lidia J Exp Clin Cancer Res Research OBJECTIVES: To implement a new cost efficacy internal Service for blood component irradiation, we carried out specific procedures and quality assurance reports using the linear accelerators (LINACs) of the Regina Elena Institute (IRE) Radiotherapy Department instead of a dedicated device. METHODS: The technical aspects, quality assurance and regulatory requirements of the internal procedure to set up a local irradiated blood bank have been defined. The LINACs of the IRE Radiotherapy Department were used to deliver a mean dose of 32 Gy and dose accuracy was checked with gafchromic film. The overall time/cost of this procedure was compared with the previous procedure, out-sourcing the irradiation of blood components. RESULTS: A total of 1996 blood component units were internally irradiated in the first year. Moreover, reducing the overall procedure time by a third. Overall cost/bag of external and internal procedures was approx. 66 € and 11 €, respectively. Thus the average saving of cost/bag was higher than 80%. The use of gafchromic films in all irradiated blood component bags allowed the accuracy of the dose delivered to blood to be checked. CONCLUSIONS: By utilizing LINACs installed in the Radiotherapy Department it is possible to provide an internal blood component irradiation service, capitalizing on internal resources without any inconvenience/discomfort to patients undergoing radiotherapy and satisfying governmental regulatory requirements. The internal irradiation procedures has proven to be safe and feasible, and along with the significant cost/time reduction suggests that it is more advantageous than external procedures. BioMed Central 2011-01-12 /pmc/articles/PMC3031252/ /pubmed/21226943 http://dx.doi.org/10.1186/1756-9966-30-7 Text en Copyright ©2011 Pinnarò et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Pinnarò, Paola
Soriani, Antonella
D'Alessio, Daniela
Giordano, Carolina
Foddai, Maria Laura
Pinzi, Valentina
Strigari, Lidia
Implementation of a new cost efficacy method for blood irradiation using a non dedicated device
title Implementation of a new cost efficacy method for blood irradiation using a non dedicated device
title_full Implementation of a new cost efficacy method for blood irradiation using a non dedicated device
title_fullStr Implementation of a new cost efficacy method for blood irradiation using a non dedicated device
title_full_unstemmed Implementation of a new cost efficacy method for blood irradiation using a non dedicated device
title_short Implementation of a new cost efficacy method for blood irradiation using a non dedicated device
title_sort implementation of a new cost efficacy method for blood irradiation using a non dedicated device
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3031252/
https://www.ncbi.nlm.nih.gov/pubmed/21226943
http://dx.doi.org/10.1186/1756-9966-30-7
work_keys_str_mv AT pinnaropaola implementationofanewcostefficacymethodforbloodirradiationusinganondedicateddevice
AT sorianiantonella implementationofanewcostefficacymethodforbloodirradiationusinganondedicateddevice
AT dalessiodaniela implementationofanewcostefficacymethodforbloodirradiationusinganondedicateddevice
AT giordanocarolina implementationofanewcostefficacymethodforbloodirradiationusinganondedicateddevice
AT foddaimarialaura implementationofanewcostefficacymethodforbloodirradiationusinganondedicateddevice
AT pinzivalentina implementationofanewcostefficacymethodforbloodirradiationusinganondedicateddevice
AT strigarilidia implementationofanewcostefficacymethodforbloodirradiationusinganondedicateddevice