Cargando…

Comparison of retinal breaks observed during 23 gauge transconjunctival vitrectomy versus conventional 20 gauge surgery for proliferative diabetic retinopathy

BACKGROUND: To assess the rate and type of retinal break formation in patients undergoing 23 gauge transconjunctival vitrectomy surgery for complications of proliferative diabetic retinopathy compared with 20 gauge vitrectomy surgery. METHODS: Retrospective case notes review of two consecutive serie...

Descripción completa

Detalles Bibliográficos
Autores principales: Issa, Sharif A, Connor, Alan, Habib, Maged, Steel, David HW
Formato: Texto
Lenguaje:English
Publicado: Dove Medical Press 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3037038/
https://www.ncbi.nlm.nih.gov/pubmed/21339803
http://dx.doi.org/10.2147/OPTH.S16414
_version_ 1782197940105773056
author Issa, Sharif A
Connor, Alan
Habib, Maged
Steel, David HW
author_facet Issa, Sharif A
Connor, Alan
Habib, Maged
Steel, David HW
author_sort Issa, Sharif A
collection PubMed
description BACKGROUND: To assess the rate and type of retinal break formation in patients undergoing 23 gauge transconjunctival vitrectomy surgery for complications of proliferative diabetic retinopathy compared with 20 gauge vitrectomy surgery. METHODS: Retrospective case notes review of two consecutive series of patients who had primary pars plana vitrectomy for complications of proliferative diabetic retinopathy by a single surgeon. The control group had standard 20 gauge vitrectomy surgery whilst the second group had 23 gauge transconjunctival vitrectomy surgery. RESULTS: Eighty-five eyes were included in the 20 gauge group and 85 eyes in the 23 gauge group. The groups were well matched for surgical complexity and indications for surgery, as well as a variety of other preoperative variables. There was a significant reduction in the incidence of peripheral sclerotomy-related retinal breaks and lesions suspicious for breaks (4/85 [5%] 23 gauge versus 14/85 [16%] 20 gauge, P = 0.02) and posterior retinal breaks (3/85 [4%] 23 gauge versus 12/85 [14%] 20 gauge, P = 0.03). Six eyes (7%) in total had definite new retinal breaks of any type detected in the 23 gauge group compared with 16 (18.8%) in the 20 gauge group (P = 0.04). One patient in each group experienced a retinal detachment postoperatively related in both cases to a posterior retinal break associated with recurrent traction. CONCLUSION: In this series of patients, 23 gauge transconjunctival vitrectomy surgery was associated with a lower rate of retinal break formation than 20 gauge vitrectomy for proliferative diabetic retinopathy.
format Text
id pubmed-3037038
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-30370382011-02-18 Comparison of retinal breaks observed during 23 gauge transconjunctival vitrectomy versus conventional 20 gauge surgery for proliferative diabetic retinopathy Issa, Sharif A Connor, Alan Habib, Maged Steel, David HW Clin Ophthalmol Original Research BACKGROUND: To assess the rate and type of retinal break formation in patients undergoing 23 gauge transconjunctival vitrectomy surgery for complications of proliferative diabetic retinopathy compared with 20 gauge vitrectomy surgery. METHODS: Retrospective case notes review of two consecutive series of patients who had primary pars plana vitrectomy for complications of proliferative diabetic retinopathy by a single surgeon. The control group had standard 20 gauge vitrectomy surgery whilst the second group had 23 gauge transconjunctival vitrectomy surgery. RESULTS: Eighty-five eyes were included in the 20 gauge group and 85 eyes in the 23 gauge group. The groups were well matched for surgical complexity and indications for surgery, as well as a variety of other preoperative variables. There was a significant reduction in the incidence of peripheral sclerotomy-related retinal breaks and lesions suspicious for breaks (4/85 [5%] 23 gauge versus 14/85 [16%] 20 gauge, P = 0.02) and posterior retinal breaks (3/85 [4%] 23 gauge versus 12/85 [14%] 20 gauge, P = 0.03). Six eyes (7%) in total had definite new retinal breaks of any type detected in the 23 gauge group compared with 16 (18.8%) in the 20 gauge group (P = 0.04). One patient in each group experienced a retinal detachment postoperatively related in both cases to a posterior retinal break associated with recurrent traction. CONCLUSION: In this series of patients, 23 gauge transconjunctival vitrectomy surgery was associated with a lower rate of retinal break formation than 20 gauge vitrectomy for proliferative diabetic retinopathy. Dove Medical Press 2011 2011-01-20 /pmc/articles/PMC3037038/ /pubmed/21339803 http://dx.doi.org/10.2147/OPTH.S16414 Text en © 2011 Issa et al, publisher and licensee Dove Medical Press Ltd. This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited.
spellingShingle Original Research
Issa, Sharif A
Connor, Alan
Habib, Maged
Steel, David HW
Comparison of retinal breaks observed during 23 gauge transconjunctival vitrectomy versus conventional 20 gauge surgery for proliferative diabetic retinopathy
title Comparison of retinal breaks observed during 23 gauge transconjunctival vitrectomy versus conventional 20 gauge surgery for proliferative diabetic retinopathy
title_full Comparison of retinal breaks observed during 23 gauge transconjunctival vitrectomy versus conventional 20 gauge surgery for proliferative diabetic retinopathy
title_fullStr Comparison of retinal breaks observed during 23 gauge transconjunctival vitrectomy versus conventional 20 gauge surgery for proliferative diabetic retinopathy
title_full_unstemmed Comparison of retinal breaks observed during 23 gauge transconjunctival vitrectomy versus conventional 20 gauge surgery for proliferative diabetic retinopathy
title_short Comparison of retinal breaks observed during 23 gauge transconjunctival vitrectomy versus conventional 20 gauge surgery for proliferative diabetic retinopathy
title_sort comparison of retinal breaks observed during 23 gauge transconjunctival vitrectomy versus conventional 20 gauge surgery for proliferative diabetic retinopathy
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3037038/
https://www.ncbi.nlm.nih.gov/pubmed/21339803
http://dx.doi.org/10.2147/OPTH.S16414
work_keys_str_mv AT issasharifa comparisonofretinalbreaksobservedduring23gaugetransconjunctivalvitrectomyversusconventional20gaugesurgeryforproliferativediabeticretinopathy
AT connoralan comparisonofretinalbreaksobservedduring23gaugetransconjunctivalvitrectomyversusconventional20gaugesurgeryforproliferativediabeticretinopathy
AT habibmaged comparisonofretinalbreaksobservedduring23gaugetransconjunctivalvitrectomyversusconventional20gaugesurgeryforproliferativediabeticretinopathy
AT steeldavidhw comparisonofretinalbreaksobservedduring23gaugetransconjunctivalvitrectomyversusconventional20gaugesurgeryforproliferativediabeticretinopathy