Cargando…

The Effect of Yellow Tinted Intraocular Lenses on the Result of Frequency Doubling Perimetry after Cataract Surgery

PURPOSE: To investigate the effect of yellow tinted intraocular lenses (IOLs), implanted in the bag after phacoemulsification, on the result of frequency doubling technique (FDT) perimetry. METHODS: For 68 eyes of 52 patients, an IOL was implanted in the bag after phacoemulsification. The patients w...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Jae-Yun, Choi, Jin-A, Na, Kyung-Sun, Joo, Choun-Ki
Formato: Texto
Lenguaje:English
Publicado: The Korean Ophthalmological Society 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3039191/
https://www.ncbi.nlm.nih.gov/pubmed/21350691
http://dx.doi.org/10.3341/kjo.2011.25.1.29
_version_ 1782198170943488000
author Kim, Jae-Yun
Choi, Jin-A
Na, Kyung-Sun
Joo, Choun-Ki
author_facet Kim, Jae-Yun
Choi, Jin-A
Na, Kyung-Sun
Joo, Choun-Ki
author_sort Kim, Jae-Yun
collection PubMed
description PURPOSE: To investigate the effect of yellow tinted intraocular lenses (IOLs), implanted in the bag after phacoemulsification, on the result of frequency doubling technique (FDT) perimetry. METHODS: For 68 eyes of 52 patients, an IOL was implanted in the bag after phacoemulsification. The patients were categorized into three groups according to the type of implanted IOLs used. IOLs were selected randomly among two types of yellow IOLs (Acrysof SN60WF IOL, Hoya YA60BBR IOL) and a clear IOL was used as a control. A FDT Humphrey matrix was performed 2 months after the surgery. The mean deviation (MD) and pattern standard deviation (PSD) among these three groups was analyzed using Mann-Whitney U-test. RESULTS: Two months after the procedure, there was no significant difference between each of the three groups: the clear IOL and Hoya YA60BBR IOL (MD, p = 0.21; PSD, p = 0.27), the clear IOL and Alcon SN60WF IOL (MD, p = 0.11; PSD, p = 0.22), and the Hoya YA60BBR IOL and Alcon SN60WF IOL (MD, p = 0.33; PSD, p = 0.56). CONCLUSIONS: When interpreting the result of the FDT after cataract surgery, the color and type of IOLs used should not be considered.
format Text
id pubmed-3039191
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher The Korean Ophthalmological Society
record_format MEDLINE/PubMed
spelling pubmed-30391912011-02-24 The Effect of Yellow Tinted Intraocular Lenses on the Result of Frequency Doubling Perimetry after Cataract Surgery Kim, Jae-Yun Choi, Jin-A Na, Kyung-Sun Joo, Choun-Ki Korean J Ophthalmol Original Article PURPOSE: To investigate the effect of yellow tinted intraocular lenses (IOLs), implanted in the bag after phacoemulsification, on the result of frequency doubling technique (FDT) perimetry. METHODS: For 68 eyes of 52 patients, an IOL was implanted in the bag after phacoemulsification. The patients were categorized into three groups according to the type of implanted IOLs used. IOLs were selected randomly among two types of yellow IOLs (Acrysof SN60WF IOL, Hoya YA60BBR IOL) and a clear IOL was used as a control. A FDT Humphrey matrix was performed 2 months after the surgery. The mean deviation (MD) and pattern standard deviation (PSD) among these three groups was analyzed using Mann-Whitney U-test. RESULTS: Two months after the procedure, there was no significant difference between each of the three groups: the clear IOL and Hoya YA60BBR IOL (MD, p = 0.21; PSD, p = 0.27), the clear IOL and Alcon SN60WF IOL (MD, p = 0.11; PSD, p = 0.22), and the Hoya YA60BBR IOL and Alcon SN60WF IOL (MD, p = 0.33; PSD, p = 0.56). CONCLUSIONS: When interpreting the result of the FDT after cataract surgery, the color and type of IOLs used should not be considered. The Korean Ophthalmological Society 2011-02 2011-01-17 /pmc/articles/PMC3039191/ /pubmed/21350691 http://dx.doi.org/10.3341/kjo.2011.25.1.29 Text en © 2011 The Korean Ophthalmological Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kim, Jae-Yun
Choi, Jin-A
Na, Kyung-Sun
Joo, Choun-Ki
The Effect of Yellow Tinted Intraocular Lenses on the Result of Frequency Doubling Perimetry after Cataract Surgery
title The Effect of Yellow Tinted Intraocular Lenses on the Result of Frequency Doubling Perimetry after Cataract Surgery
title_full The Effect of Yellow Tinted Intraocular Lenses on the Result of Frequency Doubling Perimetry after Cataract Surgery
title_fullStr The Effect of Yellow Tinted Intraocular Lenses on the Result of Frequency Doubling Perimetry after Cataract Surgery
title_full_unstemmed The Effect of Yellow Tinted Intraocular Lenses on the Result of Frequency Doubling Perimetry after Cataract Surgery
title_short The Effect of Yellow Tinted Intraocular Lenses on the Result of Frequency Doubling Perimetry after Cataract Surgery
title_sort effect of yellow tinted intraocular lenses on the result of frequency doubling perimetry after cataract surgery
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3039191/
https://www.ncbi.nlm.nih.gov/pubmed/21350691
http://dx.doi.org/10.3341/kjo.2011.25.1.29
work_keys_str_mv AT kimjaeyun theeffectofyellowtintedintraocularlensesontheresultoffrequencydoublingperimetryaftercataractsurgery
AT choijina theeffectofyellowtintedintraocularlensesontheresultoffrequencydoublingperimetryaftercataractsurgery
AT nakyungsun theeffectofyellowtintedintraocularlensesontheresultoffrequencydoublingperimetryaftercataractsurgery
AT joochounki theeffectofyellowtintedintraocularlensesontheresultoffrequencydoublingperimetryaftercataractsurgery
AT kimjaeyun effectofyellowtintedintraocularlensesontheresultoffrequencydoublingperimetryaftercataractsurgery
AT choijina effectofyellowtintedintraocularlensesontheresultoffrequencydoublingperimetryaftercataractsurgery
AT nakyungsun effectofyellowtintedintraocularlensesontheresultoffrequencydoublingperimetryaftercataractsurgery
AT joochounki effectofyellowtintedintraocularlensesontheresultoffrequencydoublingperimetryaftercataractsurgery