Cargando…

Occlusion of surgical opening of the ventricular system with fibrinogen-coated collagen fleece: a case collection study

BACKGROUND: Implantation of 1,3-bis (2-chloroethyl)-1-nitrosourea (BCNU) wafer for malignant glioma is not recommended in the case of surgical opening of the ventricular system during microsurgical tumor resection because the wafer material may dislocate from the resection cavity into the ventricula...

Descripción completa

Detalles Bibliográficos
Autores principales: Bock, Hans Christoph, Cohnen, Joseph, Keric, Naureen, Kantelhardt, Sven Rainer, Giese, Alf
Formato: Texto
Lenguaje:English
Publicado: Springer Vienna 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3040806/
https://www.ncbi.nlm.nih.gov/pubmed/21210161
http://dx.doi.org/10.1007/s00701-010-0923-z
Descripción
Sumario:BACKGROUND: Implantation of 1,3-bis (2-chloroethyl)-1-nitrosourea (BCNU) wafer for malignant glioma is not recommended in the case of surgical opening of the ventricular system during microsurgical tumor resection because the wafer material may dislocate from the resection cavity into the ventricular system and cause obstructive hydrocephalus. TachoSil is an adhesive collagen fleece used in different surgical disciplines that provides an air- and liquid-tight seal closing communications between the ventricular system and the resection cavity after tumor removal. METHODS: Occlusion of ventricular defects with TachoSil after microsurgical glioma resection was performed in two patients with newly diagnosed and seven patients with recurrent malignant glioma prior to BCNU wafer implantation into the resection cavity. Early postoperative cranial computed tomography (CCT)/MRI and follow-up MRI at 3 months’ intervals were performed with a median follow-up of 10.4 months. RESULTS: The collagen fleece was identified as a linear structure hypodense/hypointense to white matter on postoperative CT/MRI separating the resection cavity from the ventricular lumen in all cases. In no case did early CCT/MRI or follow-up MRI reveal wafer material within the ventricular system. In no case did signs of obstructive hydrocephalus occur. CONCLUSION: Sealing of the ventricular system using a fibrinogen-coated collagen fleece effectively separates the resection cavity from the ventricular system and allows implantation of BCNU wafers into the resection cavity. No morphological evidence for wafer material dislocation into the ventricular system or obstruction of CSF pathways was found in nine patients who received 41 follow-up MRI over 10.4 months of follow-up.