Cargando…
Uncovering high rates of unsafe injection equipment reuse in rural Cameroon: validation of a survey instrument that probes for specific misconceptions
BACKGROUND: Unsafe reuse of injection equipment in hospitals is an on-going threat to patient safety in many parts of Africa. The extent of this problem is difficult to measure. Standard WHO injection safety assessment protocols used in the 2003 national injection safety assessment in Cameroon are p...
Autores principales: | , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3041680/ https://www.ncbi.nlm.nih.gov/pubmed/21299899 http://dx.doi.org/10.1186/1477-7517-8-4 |
_version_ | 1782198461108584448 |
---|---|
author | Okwen, Mbah P Ngem, Bedes Y Alomba, Fozao A Capo, Mireille V Reid, Savanna R Ewang, Ebong C |
author_facet | Okwen, Mbah P Ngem, Bedes Y Alomba, Fozao A Capo, Mireille V Reid, Savanna R Ewang, Ebong C |
author_sort | Okwen, Mbah P |
collection | PubMed |
description | BACKGROUND: Unsafe reuse of injection equipment in hospitals is an on-going threat to patient safety in many parts of Africa. The extent of this problem is difficult to measure. Standard WHO injection safety assessment protocols used in the 2003 national injection safety assessment in Cameroon are problematic because health workers often behave differently under the observation of visitors. The main objective of this study is to assess the extent of unsafe injection equipment reuse and potential for blood-borne virus transmission in Cameroon. This can be done by probing for misconceptions about injection safety that explain reuse without sterilization. These misconceptions concern useless precautions against cross-contamination, i.e. "indirect reuse" of injection equipment. To investigate whether a shortage of supply explains unsafe reuse, we compared our survey data against records of purchases. METHODS: All health workers at public hospitals in two health districts in the Northwest Province of Cameroon were interviewed about their own injection practices. Injection equipment supply purchase records documented for January to December 2009 were compared with self-reported rates of syringe reuse. The number of HIV, HBV and HCV infections that result from unsafe medical injections in these health districts is estimated from the frequency of unsafe reuse, the number of injections performed, the probability that reused injection equipment had just been used on an infected patient, the size of the susceptible population, and the transmission efficiency of each virus in an injection. RESULTS: Injection equipment reuse occurs commonly in the Northwest Province of Cameroon, practiced by 44% of health workers at public hospitals. Self-reported rates of syringe reuse only partly explained by records on injection equipment supplied to these hospitals, showing a shortage of syringes where syringes are reused. Injection safety interventions could prevent an estimated 14-336 HIV infections, 248-661 HBV infections and 7-114 HCV infections each year in these health districts. CONCLUSIONS: Injection safety assessments that probe for indirect reuse may be more effective than observational assessments. The autodisable syringe may be an appropriate solution to injection safety problems in some hospitals in Cameroon. Advocacy for injection safety interventions should be a public health priority. |
format | Text |
id | pubmed-3041680 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-30416802011-02-24 Uncovering high rates of unsafe injection equipment reuse in rural Cameroon: validation of a survey instrument that probes for specific misconceptions Okwen, Mbah P Ngem, Bedes Y Alomba, Fozao A Capo, Mireille V Reid, Savanna R Ewang, Ebong C Harm Reduct J Research BACKGROUND: Unsafe reuse of injection equipment in hospitals is an on-going threat to patient safety in many parts of Africa. The extent of this problem is difficult to measure. Standard WHO injection safety assessment protocols used in the 2003 national injection safety assessment in Cameroon are problematic because health workers often behave differently under the observation of visitors. The main objective of this study is to assess the extent of unsafe injection equipment reuse and potential for blood-borne virus transmission in Cameroon. This can be done by probing for misconceptions about injection safety that explain reuse without sterilization. These misconceptions concern useless precautions against cross-contamination, i.e. "indirect reuse" of injection equipment. To investigate whether a shortage of supply explains unsafe reuse, we compared our survey data against records of purchases. METHODS: All health workers at public hospitals in two health districts in the Northwest Province of Cameroon were interviewed about their own injection practices. Injection equipment supply purchase records documented for January to December 2009 were compared with self-reported rates of syringe reuse. The number of HIV, HBV and HCV infections that result from unsafe medical injections in these health districts is estimated from the frequency of unsafe reuse, the number of injections performed, the probability that reused injection equipment had just been used on an infected patient, the size of the susceptible population, and the transmission efficiency of each virus in an injection. RESULTS: Injection equipment reuse occurs commonly in the Northwest Province of Cameroon, practiced by 44% of health workers at public hospitals. Self-reported rates of syringe reuse only partly explained by records on injection equipment supplied to these hospitals, showing a shortage of syringes where syringes are reused. Injection safety interventions could prevent an estimated 14-336 HIV infections, 248-661 HBV infections and 7-114 HCV infections each year in these health districts. CONCLUSIONS: Injection safety assessments that probe for indirect reuse may be more effective than observational assessments. The autodisable syringe may be an appropriate solution to injection safety problems in some hospitals in Cameroon. Advocacy for injection safety interventions should be a public health priority. BioMed Central 2011-02-07 /pmc/articles/PMC3041680/ /pubmed/21299899 http://dx.doi.org/10.1186/1477-7517-8-4 Text en Copyright ©2011 Okwen et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Okwen, Mbah P Ngem, Bedes Y Alomba, Fozao A Capo, Mireille V Reid, Savanna R Ewang, Ebong C Uncovering high rates of unsafe injection equipment reuse in rural Cameroon: validation of a survey instrument that probes for specific misconceptions |
title | Uncovering high rates of unsafe injection equipment reuse in rural Cameroon: validation of a survey instrument that probes for specific misconceptions |
title_full | Uncovering high rates of unsafe injection equipment reuse in rural Cameroon: validation of a survey instrument that probes for specific misconceptions |
title_fullStr | Uncovering high rates of unsafe injection equipment reuse in rural Cameroon: validation of a survey instrument that probes for specific misconceptions |
title_full_unstemmed | Uncovering high rates of unsafe injection equipment reuse in rural Cameroon: validation of a survey instrument that probes for specific misconceptions |
title_short | Uncovering high rates of unsafe injection equipment reuse in rural Cameroon: validation of a survey instrument that probes for specific misconceptions |
title_sort | uncovering high rates of unsafe injection equipment reuse in rural cameroon: validation of a survey instrument that probes for specific misconceptions |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3041680/ https://www.ncbi.nlm.nih.gov/pubmed/21299899 http://dx.doi.org/10.1186/1477-7517-8-4 |
work_keys_str_mv | AT okwenmbahp uncoveringhighratesofunsafeinjectionequipmentreuseinruralcameroonvalidationofasurveyinstrumentthatprobesforspecificmisconceptions AT ngembedesy uncoveringhighratesofunsafeinjectionequipmentreuseinruralcameroonvalidationofasurveyinstrumentthatprobesforspecificmisconceptions AT alombafozaoa uncoveringhighratesofunsafeinjectionequipmentreuseinruralcameroonvalidationofasurveyinstrumentthatprobesforspecificmisconceptions AT capomireillev uncoveringhighratesofunsafeinjectionequipmentreuseinruralcameroonvalidationofasurveyinstrumentthatprobesforspecificmisconceptions AT reidsavannar uncoveringhighratesofunsafeinjectionequipmentreuseinruralcameroonvalidationofasurveyinstrumentthatprobesforspecificmisconceptions AT ewangebongc uncoveringhighratesofunsafeinjectionequipmentreuseinruralcameroonvalidationofasurveyinstrumentthatprobesforspecificmisconceptions |