Cargando…

Ambulatory oxygen: why do COPD patients not use their portable systems as prescribed? A qualitative study

BACKGROUND: Patients with COPD on long term oxygen therapy frequently do not adhere to their prescription, and they frequently do not use their ambulatory oxygen systems as intended. Reasons for this lack of adherence are not known. The aim of this study was to obtain in-depth information about perc...

Descripción completa

Detalles Bibliográficos
Autores principales: Arnold, Elizabeth, Bruton, Anne, Donovan-Hall, Maggie, Fenwick, Angela, Dibb, Bridget, Walker, Elizabeth
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3045998/
https://www.ncbi.nlm.nih.gov/pubmed/21314932
http://dx.doi.org/10.1186/1471-2466-11-9
_version_ 1782198902209904640
author Arnold, Elizabeth
Bruton, Anne
Donovan-Hall, Maggie
Fenwick, Angela
Dibb, Bridget
Walker, Elizabeth
author_facet Arnold, Elizabeth
Bruton, Anne
Donovan-Hall, Maggie
Fenwick, Angela
Dibb, Bridget
Walker, Elizabeth
author_sort Arnold, Elizabeth
collection PubMed
description BACKGROUND: Patients with COPD on long term oxygen therapy frequently do not adhere to their prescription, and they frequently do not use their ambulatory oxygen systems as intended. Reasons for this lack of adherence are not known. The aim of this study was to obtain in-depth information about perceptions and use of prescribed ambulatory oxygen systems from patients with COPD to inform ambulatory oxygen design, prescription and management. METHODS: A qualitative design was used, involving semi-structured face-to-face interviews informed by a grounded theory approach. Twenty-seven UK community-dwelling COPD patients using NHS prescribed ambulatory systems were recruited. Ambulatory oxygen systems comprised cylinders weighing 3.4 kg, a shoulder bag and nasal cannulae. RESULTS: Participants reported that they: received no instruction on how to use ambulatory oxygen; were uncertain of the benefits; were afraid the system would run out while they were using it (due to lack of confidence in the cylinder gauge); were embarrassed at being seen with the system in public; and were unable to carry the system because of the cylinder weight. The essential role of carers was also highlighted, as participants with no immediate carers did not use ambulatory oxygen outside the house. CONCLUSIONS: These participants highlighted previously unreported problems that prevented them from using ambulatory oxygen as prescribed. Our novel findings point to: concerns with the lack of specific information provision; the perceived unreliability of the oxygen system; important carer issues surrounding managing and using ambulatory oxygen equipment. All of these issues, as well as previously reported problems with system weight and patient embarrassment, should be addressed to improve adherence to ambulatory oxygen prescription and enhance the physical and social benefits of maintaining mobility in this patient group. Increased user involvement in both system development and service provision planning, could have avoided many of the difficulties highlighted by this study.
format Text
id pubmed-3045998
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-30459982011-03-01 Ambulatory oxygen: why do COPD patients not use their portable systems as prescribed? A qualitative study Arnold, Elizabeth Bruton, Anne Donovan-Hall, Maggie Fenwick, Angela Dibb, Bridget Walker, Elizabeth BMC Pulm Med Research Article BACKGROUND: Patients with COPD on long term oxygen therapy frequently do not adhere to their prescription, and they frequently do not use their ambulatory oxygen systems as intended. Reasons for this lack of adherence are not known. The aim of this study was to obtain in-depth information about perceptions and use of prescribed ambulatory oxygen systems from patients with COPD to inform ambulatory oxygen design, prescription and management. METHODS: A qualitative design was used, involving semi-structured face-to-face interviews informed by a grounded theory approach. Twenty-seven UK community-dwelling COPD patients using NHS prescribed ambulatory systems were recruited. Ambulatory oxygen systems comprised cylinders weighing 3.4 kg, a shoulder bag and nasal cannulae. RESULTS: Participants reported that they: received no instruction on how to use ambulatory oxygen; were uncertain of the benefits; were afraid the system would run out while they were using it (due to lack of confidence in the cylinder gauge); were embarrassed at being seen with the system in public; and were unable to carry the system because of the cylinder weight. The essential role of carers was also highlighted, as participants with no immediate carers did not use ambulatory oxygen outside the house. CONCLUSIONS: These participants highlighted previously unreported problems that prevented them from using ambulatory oxygen as prescribed. Our novel findings point to: concerns with the lack of specific information provision; the perceived unreliability of the oxygen system; important carer issues surrounding managing and using ambulatory oxygen equipment. All of these issues, as well as previously reported problems with system weight and patient embarrassment, should be addressed to improve adherence to ambulatory oxygen prescription and enhance the physical and social benefits of maintaining mobility in this patient group. Increased user involvement in both system development and service provision planning, could have avoided many of the difficulties highlighted by this study. BioMed Central 2011-02-11 /pmc/articles/PMC3045998/ /pubmed/21314932 http://dx.doi.org/10.1186/1471-2466-11-9 Text en Copyright ©2011 Arnold et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Arnold, Elizabeth
Bruton, Anne
Donovan-Hall, Maggie
Fenwick, Angela
Dibb, Bridget
Walker, Elizabeth
Ambulatory oxygen: why do COPD patients not use their portable systems as prescribed? A qualitative study
title Ambulatory oxygen: why do COPD patients not use their portable systems as prescribed? A qualitative study
title_full Ambulatory oxygen: why do COPD patients not use their portable systems as prescribed? A qualitative study
title_fullStr Ambulatory oxygen: why do COPD patients not use their portable systems as prescribed? A qualitative study
title_full_unstemmed Ambulatory oxygen: why do COPD patients not use their portable systems as prescribed? A qualitative study
title_short Ambulatory oxygen: why do COPD patients not use their portable systems as prescribed? A qualitative study
title_sort ambulatory oxygen: why do copd patients not use their portable systems as prescribed? a qualitative study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3045998/
https://www.ncbi.nlm.nih.gov/pubmed/21314932
http://dx.doi.org/10.1186/1471-2466-11-9
work_keys_str_mv AT arnoldelizabeth ambulatoryoxygenwhydocopdpatientsnotusetheirportablesystemsasprescribedaqualitativestudy
AT brutonanne ambulatoryoxygenwhydocopdpatientsnotusetheirportablesystemsasprescribedaqualitativestudy
AT donovanhallmaggie ambulatoryoxygenwhydocopdpatientsnotusetheirportablesystemsasprescribedaqualitativestudy
AT fenwickangela ambulatoryoxygenwhydocopdpatientsnotusetheirportablesystemsasprescribedaqualitativestudy
AT dibbbridget ambulatoryoxygenwhydocopdpatientsnotusetheirportablesystemsasprescribedaqualitativestudy
AT walkerelizabeth ambulatoryoxygenwhydocopdpatientsnotusetheirportablesystemsasprescribedaqualitativestudy