Hybrid use of early and quasi-continuous wave photons in time-domain tomographic imaging for improved resolution and quantitative accuracy
Measurement of early-photons (EPs) from a pulsed laser source has been shown to improve imaging resolution versus continuous wave (CW) systems in diffuse optical tomography (DOT) and fluorescence mediated tomography (FMT). However, EP systems also have reduced noise performance versus CW systems sin...
Autores principales: | , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Optical Society of America
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3047371/ https://www.ncbi.nlm.nih.gov/pubmed/21412471 http://dx.doi.org/10.1364/BOE.2.000665 |
_version_ | 1782199034267566080 |
---|---|
author | Li, Zhi Niedre, Mark |
author_facet | Li, Zhi Niedre, Mark |
author_sort | Li, Zhi |
collection | PubMed |
description | Measurement of early-photons (EPs) from a pulsed laser source has been shown to improve imaging resolution versus continuous wave (CW) systems in diffuse optical tomography (DOT) and fluorescence mediated tomography (FMT). However, EP systems also have reduced noise performance versus CW systems since EP measurements require temporal rejection of large numbers of transmitted photons. In this work, we describe a ‘hybrid data set’ (HDS) image reconstruction approach, the goal of which was to produce a final image that retained the resolution and noise advantages of EP and CW data sets, respectively. Here, CW data was first reconstructed to produce a quantitatively accurate ‘initial guess’ intermediate image, and then this was refined with EP data to yield a higher resolution final image. We performed a series of studies with simulated data to test the resolution, quantitative accuracy and detection sensitivity of the approach. We showed that in principle it was possible to produce final images that retained the bulk of the resolution and quantitative accuracy of EP and CW images, respectively, but the HDS approach did not improve the instrument sensitivity compared to EP data alone. |
format | Text |
id | pubmed-3047371 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Optical Society of America |
record_format | MEDLINE/PubMed |
spelling | pubmed-30473712011-03-16 Hybrid use of early and quasi-continuous wave photons in time-domain tomographic imaging for improved resolution and quantitative accuracy Li, Zhi Niedre, Mark Biomed Opt Express Optics of Tissue and Turbid Media Measurement of early-photons (EPs) from a pulsed laser source has been shown to improve imaging resolution versus continuous wave (CW) systems in diffuse optical tomography (DOT) and fluorescence mediated tomography (FMT). However, EP systems also have reduced noise performance versus CW systems since EP measurements require temporal rejection of large numbers of transmitted photons. In this work, we describe a ‘hybrid data set’ (HDS) image reconstruction approach, the goal of which was to produce a final image that retained the resolution and noise advantages of EP and CW data sets, respectively. Here, CW data was first reconstructed to produce a quantitatively accurate ‘initial guess’ intermediate image, and then this was refined with EP data to yield a higher resolution final image. We performed a series of studies with simulated data to test the resolution, quantitative accuracy and detection sensitivity of the approach. We showed that in principle it was possible to produce final images that retained the bulk of the resolution and quantitative accuracy of EP and CW images, respectively, but the HDS approach did not improve the instrument sensitivity compared to EP data alone. Optical Society of America 2011-02-23 /pmc/articles/PMC3047371/ /pubmed/21412471 http://dx.doi.org/10.1364/BOE.2.000665 Text en ©2011 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially. |
spellingShingle | Optics of Tissue and Turbid Media Li, Zhi Niedre, Mark Hybrid use of early and quasi-continuous wave photons in time-domain tomographic imaging for improved resolution and quantitative accuracy |
title | Hybrid use of early and quasi-continuous wave photons in time-domain tomographic imaging for improved resolution and quantitative accuracy |
title_full | Hybrid use of early and quasi-continuous wave photons in time-domain tomographic imaging for improved resolution and quantitative accuracy |
title_fullStr | Hybrid use of early and quasi-continuous wave photons in time-domain tomographic imaging for improved resolution and quantitative accuracy |
title_full_unstemmed | Hybrid use of early and quasi-continuous wave photons in time-domain tomographic imaging for improved resolution and quantitative accuracy |
title_short | Hybrid use of early and quasi-continuous wave photons in time-domain tomographic imaging for improved resolution and quantitative accuracy |
title_sort | hybrid use of early and quasi-continuous wave photons in time-domain tomographic imaging for improved resolution and quantitative accuracy |
topic | Optics of Tissue and Turbid Media |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3047371/ https://www.ncbi.nlm.nih.gov/pubmed/21412471 http://dx.doi.org/10.1364/BOE.2.000665 |
work_keys_str_mv | AT lizhi hybriduseofearlyandquasicontinuouswavephotonsintimedomaintomographicimagingforimprovedresolutionandquantitativeaccuracy AT niedremark hybriduseofearlyandquasicontinuouswavephotonsintimedomaintomographicimagingforimprovedresolutionandquantitativeaccuracy |