Cargando…

Morphometric Measurements of Cadaveric Thoracic Spine in Indian Population and Its Clinical Applications

STUDY DESIGN: Analysis of morphometric data obtained from direct measurements of 100 cadaveric thoracic spines in Indian population. PURPOSE: To collect a base line morphometric data and analyze it in reference to the musculoskeletal anatomy and biomechanics of the spine; implants and instrumentatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Singh, Roop, Srivastva, Sunil Kumar, Prasath, Chittode Sachudanandam Vishnu, Rohilla, Rajesh Kumar, Siwach, Ramchander, Magu, Narender Kumar
Formato: Texto
Lenguaje:English
Publicado: Korean Society of Spine Surgery 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3047895/
https://www.ncbi.nlm.nih.gov/pubmed/21386943
http://dx.doi.org/10.4184/asj.2011.5.1.20
_version_ 1782199093309734912
author Singh, Roop
Srivastva, Sunil Kumar
Prasath, Chittode Sachudanandam Vishnu
Rohilla, Rajesh Kumar
Siwach, Ramchander
Magu, Narender Kumar
author_facet Singh, Roop
Srivastva, Sunil Kumar
Prasath, Chittode Sachudanandam Vishnu
Rohilla, Rajesh Kumar
Siwach, Ramchander
Magu, Narender Kumar
author_sort Singh, Roop
collection PubMed
description STUDY DESIGN: Analysis of morphometric data obtained from direct measurements of 100 cadaveric thoracic spines in Indian population. PURPOSE: To collect a base line morphometric data and analyze it in reference to the musculoskeletal anatomy and biomechanics of the spine; implants and instrumentations; and to suggest the requisite modification in spinal surgery instrumentations. OVERVIEW OF LITERATURE: Most of the previous studies in the world literature have focused primarily on the parameters of the pedicle and to the authors' knowledge; no study has been published from the Indian subcontinent reporting a detailed morphometry of the thoracic spine. METHODS: One thousand and two hundred thoracic vertebrae were studied by direct measurements for linear and angular dimensions of the vertebral body, spinal canal, pedicle, and spinous and transverse processes in 100 human cadavers. RESULTS: Thirty-five point five percent of all the pedicles; 71% of T5 pedicles; 54.6% of all the female pedicles; and 94.4% of the T5 pedicles in females were smaller than 5 mm in mid-pedicle width dimension. Transverse pedicle angle was more at all levels and pedicles were sagittaly angulated in cephalad direction in comparison to other studies. Minimum value of interpedicular distance was at T5 (15.48 ± 1.24). Vertebral body width showed slight decrease from T1 to T4. The transverse process length was relatively constant between T2 to T10. The spinous process angle showed increasing trend from T1 to T6 and then gradually decreased to T12. CONCLUSIONS: Most of the trends in changes of the parameters from T1 to T12 can be explained on the basis of local musculoskeletal anatomy and biomechanical stresses. The smallest diameter screw and shortest available screw for adults may not be safe in majority of the Indian population in mid-thoracic region. The results of the present study can help in designing implants and instrumentations; understanding spine pathologies; and management of spinal disorders in this part of the world.
format Text
id pubmed-3047895
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Korean Society of Spine Surgery
record_format MEDLINE/PubMed
spelling pubmed-30478952011-03-08 Morphometric Measurements of Cadaveric Thoracic Spine in Indian Population and Its Clinical Applications Singh, Roop Srivastva, Sunil Kumar Prasath, Chittode Sachudanandam Vishnu Rohilla, Rajesh Kumar Siwach, Ramchander Magu, Narender Kumar Asian Spine J Clinical Study STUDY DESIGN: Analysis of morphometric data obtained from direct measurements of 100 cadaveric thoracic spines in Indian population. PURPOSE: To collect a base line morphometric data and analyze it in reference to the musculoskeletal anatomy and biomechanics of the spine; implants and instrumentations; and to suggest the requisite modification in spinal surgery instrumentations. OVERVIEW OF LITERATURE: Most of the previous studies in the world literature have focused primarily on the parameters of the pedicle and to the authors' knowledge; no study has been published from the Indian subcontinent reporting a detailed morphometry of the thoracic spine. METHODS: One thousand and two hundred thoracic vertebrae were studied by direct measurements for linear and angular dimensions of the vertebral body, spinal canal, pedicle, and spinous and transverse processes in 100 human cadavers. RESULTS: Thirty-five point five percent of all the pedicles; 71% of T5 pedicles; 54.6% of all the female pedicles; and 94.4% of the T5 pedicles in females were smaller than 5 mm in mid-pedicle width dimension. Transverse pedicle angle was more at all levels and pedicles were sagittaly angulated in cephalad direction in comparison to other studies. Minimum value of interpedicular distance was at T5 (15.48 ± 1.24). Vertebral body width showed slight decrease from T1 to T4. The transverse process length was relatively constant between T2 to T10. The spinous process angle showed increasing trend from T1 to T6 and then gradually decreased to T12. CONCLUSIONS: Most of the trends in changes of the parameters from T1 to T12 can be explained on the basis of local musculoskeletal anatomy and biomechanical stresses. The smallest diameter screw and shortest available screw for adults may not be safe in majority of the Indian population in mid-thoracic region. The results of the present study can help in designing implants and instrumentations; understanding spine pathologies; and management of spinal disorders in this part of the world. Korean Society of Spine Surgery 2011-03 2011-03-02 /pmc/articles/PMC3047895/ /pubmed/21386943 http://dx.doi.org/10.4184/asj.2011.5.1.20 Text en Copyright © 2011 by Korean Society of Spine Surgery http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
Singh, Roop
Srivastva, Sunil Kumar
Prasath, Chittode Sachudanandam Vishnu
Rohilla, Rajesh Kumar
Siwach, Ramchander
Magu, Narender Kumar
Morphometric Measurements of Cadaveric Thoracic Spine in Indian Population and Its Clinical Applications
title Morphometric Measurements of Cadaveric Thoracic Spine in Indian Population and Its Clinical Applications
title_full Morphometric Measurements of Cadaveric Thoracic Spine in Indian Population and Its Clinical Applications
title_fullStr Morphometric Measurements of Cadaveric Thoracic Spine in Indian Population and Its Clinical Applications
title_full_unstemmed Morphometric Measurements of Cadaveric Thoracic Spine in Indian Population and Its Clinical Applications
title_short Morphometric Measurements of Cadaveric Thoracic Spine in Indian Population and Its Clinical Applications
title_sort morphometric measurements of cadaveric thoracic spine in indian population and its clinical applications
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3047895/
https://www.ncbi.nlm.nih.gov/pubmed/21386943
http://dx.doi.org/10.4184/asj.2011.5.1.20
work_keys_str_mv AT singhroop morphometricmeasurementsofcadavericthoracicspineinindianpopulationanditsclinicalapplications
AT srivastvasunilkumar morphometricmeasurementsofcadavericthoracicspineinindianpopulationanditsclinicalapplications
AT prasathchittodesachudanandamvishnu morphometricmeasurementsofcadavericthoracicspineinindianpopulationanditsclinicalapplications
AT rohillarajeshkumar morphometricmeasurementsofcadavericthoracicspineinindianpopulationanditsclinicalapplications
AT siwachramchander morphometricmeasurementsofcadavericthoracicspineinindianpopulationanditsclinicalapplications
AT magunarenderkumar morphometricmeasurementsofcadavericthoracicspineinindianpopulationanditsclinicalapplications