Reconstruction Algorithms Influence the Follow-Up Variability in the Longitudinal CT Emphysema Index Measurements
OBJECTIVE: We wanted to compare the variability in the longitudinal emphysema index (EI) measurements that were computed with standard and high resolution (HR) reconstruction algorithms (RAs). MATERIALS AND METHODS: We performed a retrospective review of 475 patients who underwent CT for surveillanc...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3052607/ https://www.ncbi.nlm.nih.gov/pubmed/21430933 http://dx.doi.org/10.3348/kjr.2011.12.2.169 |
_version_ | 1782199699173801984 |
---|---|
author | Hochhegger, Bruno Irion, Klaus Loureiro Marchiori, Edson Moreira, Jose Silva |
author_facet | Hochhegger, Bruno Irion, Klaus Loureiro Marchiori, Edson Moreira, Jose Silva |
author_sort | Hochhegger, Bruno |
collection | PubMed |
description | OBJECTIVE: We wanted to compare the variability in the longitudinal emphysema index (EI) measurements that were computed with standard and high resolution (HR) reconstruction algorithms (RAs). MATERIALS AND METHODS: We performed a retrospective review of 475 patients who underwent CT for surveillance of lung nodules. From this cohort, 50 patients (28 male) were included in the study. For these patients, the baseline and follow-up scans were acquired on the same multidetector CT scanner and using the same acquisition protocol. The CT scans were reconstructed with HR and standard RAs. We determined the difference in the EI between CT1 and CT2 for the HR and standard RAs, and we compared the variance of these differences. RESULTS: The mean of the variation of the total lung volume was 0.14 L (standard deviation [SD] = 0.13 L) for the standard RA and 0.16 L (SD = 0.15 L) for the HR RA. These differences were not significant. For the standard RA, the mean variation was 0.13% (SD = 0.44%) for EI -970 and 0.4% (SD = 0.88%) for EI -950; for the HR RA, the mean variation was 1.9% (SD = 2.2%) for EI -970 and 3.6% (SD = 3.7%) for EI -950. These differences were significant. CONCLUSION: Using an HR RA appears to increase the variability of the CT measurements of the EI. |
format | Text |
id | pubmed-3052607 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-30526072011-03-22 Reconstruction Algorithms Influence the Follow-Up Variability in the Longitudinal CT Emphysema Index Measurements Hochhegger, Bruno Irion, Klaus Loureiro Marchiori, Edson Moreira, Jose Silva Korean J Radiol Original Article OBJECTIVE: We wanted to compare the variability in the longitudinal emphysema index (EI) measurements that were computed with standard and high resolution (HR) reconstruction algorithms (RAs). MATERIALS AND METHODS: We performed a retrospective review of 475 patients who underwent CT for surveillance of lung nodules. From this cohort, 50 patients (28 male) were included in the study. For these patients, the baseline and follow-up scans were acquired on the same multidetector CT scanner and using the same acquisition protocol. The CT scans were reconstructed with HR and standard RAs. We determined the difference in the EI between CT1 and CT2 for the HR and standard RAs, and we compared the variance of these differences. RESULTS: The mean of the variation of the total lung volume was 0.14 L (standard deviation [SD] = 0.13 L) for the standard RA and 0.16 L (SD = 0.15 L) for the HR RA. These differences were not significant. For the standard RA, the mean variation was 0.13% (SD = 0.44%) for EI -970 and 0.4% (SD = 0.88%) for EI -950; for the HR RA, the mean variation was 1.9% (SD = 2.2%) for EI -970 and 3.6% (SD = 3.7%) for EI -950. These differences were significant. CONCLUSION: Using an HR RA appears to increase the variability of the CT measurements of the EI. The Korean Society of Radiology 2011 2011-03-03 /pmc/articles/PMC3052607/ /pubmed/21430933 http://dx.doi.org/10.3348/kjr.2011.12.2.169 Text en Copyright © 2011 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Hochhegger, Bruno Irion, Klaus Loureiro Marchiori, Edson Moreira, Jose Silva Reconstruction Algorithms Influence the Follow-Up Variability in the Longitudinal CT Emphysema Index Measurements |
title | Reconstruction Algorithms Influence the Follow-Up Variability in the Longitudinal CT Emphysema Index Measurements |
title_full | Reconstruction Algorithms Influence the Follow-Up Variability in the Longitudinal CT Emphysema Index Measurements |
title_fullStr | Reconstruction Algorithms Influence the Follow-Up Variability in the Longitudinal CT Emphysema Index Measurements |
title_full_unstemmed | Reconstruction Algorithms Influence the Follow-Up Variability in the Longitudinal CT Emphysema Index Measurements |
title_short | Reconstruction Algorithms Influence the Follow-Up Variability in the Longitudinal CT Emphysema Index Measurements |
title_sort | reconstruction algorithms influence the follow-up variability in the longitudinal ct emphysema index measurements |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3052607/ https://www.ncbi.nlm.nih.gov/pubmed/21430933 http://dx.doi.org/10.3348/kjr.2011.12.2.169 |
work_keys_str_mv | AT hochheggerbruno reconstructionalgorithmsinfluencethefollowupvariabilityinthelongitudinalctemphysemaindexmeasurements AT irionklausloureiro reconstructionalgorithmsinfluencethefollowupvariabilityinthelongitudinalctemphysemaindexmeasurements AT marchioriedson reconstructionalgorithmsinfluencethefollowupvariabilityinthelongitudinalctemphysemaindexmeasurements AT moreirajosesilva reconstructionalgorithmsinfluencethefollowupvariabilityinthelongitudinalctemphysemaindexmeasurements |