Cargando…

Reverse-SSO hybridization provides an accurate and simple HLA-DR typing--a comparative study with HLA-DR serologic typing.

The HLA-DR molecule is a polymorphic membrane glycoprotein and one of the key molecules causing allograft rejection and graft-versus-host disease in organ transplantation. Serologic typing using DR specific alloantisera has long been used, but several problems have limited its application. The purpo...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, K. W., Cho, H. C.
Formato: Texto
Lenguaje:English
Publicado: Korean Academy of Medical Sciences 1994
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3054199/
https://www.ncbi.nlm.nih.gov/pubmed/7702791
_version_ 1782199887633317888
author Lee, K. W.
Cho, H. C.
author_facet Lee, K. W.
Cho, H. C.
author_sort Lee, K. W.
collection PubMed
description The HLA-DR molecule is a polymorphic membrane glycoprotein and one of the key molecules causing allograft rejection and graft-versus-host disease in organ transplantation. Serologic typing using DR specific alloantisera has long been used, but several problems have limited its application. The purpose of this study was to establish an efficient reverse-SSO typing system that detects DRB1 and DRB3/B4/B5 alleles on a single membrane. A DR typing membrane was prepared by immobilizing 21 dT-tailed sequence specific oligonucleotides (SSOs) on a nylon membrane and was used in a hybridization assay with digoxigenin-labeled PCR-amplified target DNA. The positive signals were detected on X-ray film using chemiluminescence. A comparison study with serology using DNAs from 105 unrelated individuals demonstrated that the reverse-SSO typing system was superior to serologic typing in terms of accuracy (100% vs 90.5%), simplicity, range of application, rapidity, and cost of the test. These data indicate that the reverse-SSO typing system can replace serology as a routine DR test, and will be useful in time-restricted solid organ transplantation and in selection of an unrelated marrow donor prior to bone marrow transplantation.
format Text
id pubmed-3054199
institution National Center for Biotechnology Information
language English
publishDate 1994
publisher Korean Academy of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-30541992011-03-15 Reverse-SSO hybridization provides an accurate and simple HLA-DR typing--a comparative study with HLA-DR serologic typing. Lee, K. W. Cho, H. C. J Korean Med Sci Research Article The HLA-DR molecule is a polymorphic membrane glycoprotein and one of the key molecules causing allograft rejection and graft-versus-host disease in organ transplantation. Serologic typing using DR specific alloantisera has long been used, but several problems have limited its application. The purpose of this study was to establish an efficient reverse-SSO typing system that detects DRB1 and DRB3/B4/B5 alleles on a single membrane. A DR typing membrane was prepared by immobilizing 21 dT-tailed sequence specific oligonucleotides (SSOs) on a nylon membrane and was used in a hybridization assay with digoxigenin-labeled PCR-amplified target DNA. The positive signals were detected on X-ray film using chemiluminescence. A comparison study with serology using DNAs from 105 unrelated individuals demonstrated that the reverse-SSO typing system was superior to serologic typing in terms of accuracy (100% vs 90.5%), simplicity, range of application, rapidity, and cost of the test. These data indicate that the reverse-SSO typing system can replace serology as a routine DR test, and will be useful in time-restricted solid organ transplantation and in selection of an unrelated marrow donor prior to bone marrow transplantation. Korean Academy of Medical Sciences 1994-10 /pmc/articles/PMC3054199/ /pubmed/7702791 Text en
spellingShingle Research Article
Lee, K. W.
Cho, H. C.
Reverse-SSO hybridization provides an accurate and simple HLA-DR typing--a comparative study with HLA-DR serologic typing.
title Reverse-SSO hybridization provides an accurate and simple HLA-DR typing--a comparative study with HLA-DR serologic typing.
title_full Reverse-SSO hybridization provides an accurate and simple HLA-DR typing--a comparative study with HLA-DR serologic typing.
title_fullStr Reverse-SSO hybridization provides an accurate and simple HLA-DR typing--a comparative study with HLA-DR serologic typing.
title_full_unstemmed Reverse-SSO hybridization provides an accurate and simple HLA-DR typing--a comparative study with HLA-DR serologic typing.
title_short Reverse-SSO hybridization provides an accurate and simple HLA-DR typing--a comparative study with HLA-DR serologic typing.
title_sort reverse-sso hybridization provides an accurate and simple hla-dr typing--a comparative study with hla-dr serologic typing.
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3054199/
https://www.ncbi.nlm.nih.gov/pubmed/7702791
work_keys_str_mv AT leekw reversessohybridizationprovidesanaccurateandsimplehladrtypingacomparativestudywithhladrserologictyping
AT chohc reversessohybridizationprovidesanaccurateandsimplehladrtypingacomparativestudywithhladrserologictyping