Cargando…

Assessment of coronary flow reserve with transthoracic Doppler echocardiography: comparison with intracoronary Doppler method.

To evaluate the feasibility and usefulness of transthoracic Doppler echocardiography (TTDE) as a non-invasive method in recording distal anterior descending (LAD) coronary flow velocity, we compared coronary flow reserve (CFR) measured by TTDE with measurements by intracoronary Doppler wire (ICDW)....

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, S. M., Shim, W. J., Lim, H. E., Hwang, G. S., Song, W. H., Lim, D. S., Kim, Y. H., Seo, H. S., Oh, D. J., Ro, Y. M.
Formato: Texto
Lenguaje:English
Publicado: Korean Academy of Medical Sciences 2000
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3054624/
https://www.ncbi.nlm.nih.gov/pubmed/10803688
_version_ 1782199991011377152
author Kim, S. M.
Shim, W. J.
Lim, H. E.
Hwang, G. S.
Song, W. H.
Lim, D. S.
Kim, Y. H.
Seo, H. S.
Oh, D. J.
Ro, Y. M.
author_facet Kim, S. M.
Shim, W. J.
Lim, H. E.
Hwang, G. S.
Song, W. H.
Lim, D. S.
Kim, Y. H.
Seo, H. S.
Oh, D. J.
Ro, Y. M.
author_sort Kim, S. M.
collection PubMed
description To evaluate the feasibility and usefulness of transthoracic Doppler echocardiography (TTDE) as a non-invasive method in recording distal anterior descending (LAD) coronary flow velocity, we compared coronary flow reserve (CFR) measured by TTDE with measurements by intracoronary Doppler wire (ICDW). Twenty-one patients without LAD stenosis were studied. ICDW performed at baseline and after intracoronary injection of 18 microg adenosine. TTDE was performed at baseline and after intravenous adenosine (140 microg/kgmin for 2 min). Adequate Doppler recordings of coronary flow velocities during systole were obtained in 14 of 21 study patients (67%) and during diastole in 17 (81%) patients. Baseline and hyperemic peak diastolic flow velocities measured by TTDE were significantly smaller than those obtained by ICDW (p<0.05). However, diminishing trends of diastolic and systolic velocity ratio after hyperemia were similarly observed in both methods. CFR obtained by TTDE (3.0+/-0.5), was higher than the value calculated by ICDW (2.5+/-0.4). There were significant correlations between the values obtained by the two methods (r=0.72, p<0.01). It is concluded that TTDE is a feasible method in measuring coronary flow velocity and appears to be a promising non-invasive method in evaluating CFR.
format Text
id pubmed-3054624
institution National Center for Biotechnology Information
language English
publishDate 2000
publisher Korean Academy of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-30546242011-03-15 Assessment of coronary flow reserve with transthoracic Doppler echocardiography: comparison with intracoronary Doppler method. Kim, S. M. Shim, W. J. Lim, H. E. Hwang, G. S. Song, W. H. Lim, D. S. Kim, Y. H. Seo, H. S. Oh, D. J. Ro, Y. M. J Korean Med Sci Research Article To evaluate the feasibility and usefulness of transthoracic Doppler echocardiography (TTDE) as a non-invasive method in recording distal anterior descending (LAD) coronary flow velocity, we compared coronary flow reserve (CFR) measured by TTDE with measurements by intracoronary Doppler wire (ICDW). Twenty-one patients without LAD stenosis were studied. ICDW performed at baseline and after intracoronary injection of 18 microg adenosine. TTDE was performed at baseline and after intravenous adenosine (140 microg/kgmin for 2 min). Adequate Doppler recordings of coronary flow velocities during systole were obtained in 14 of 21 study patients (67%) and during diastole in 17 (81%) patients. Baseline and hyperemic peak diastolic flow velocities measured by TTDE were significantly smaller than those obtained by ICDW (p<0.05). However, diminishing trends of diastolic and systolic velocity ratio after hyperemia were similarly observed in both methods. CFR obtained by TTDE (3.0+/-0.5), was higher than the value calculated by ICDW (2.5+/-0.4). There were significant correlations between the values obtained by the two methods (r=0.72, p<0.01). It is concluded that TTDE is a feasible method in measuring coronary flow velocity and appears to be a promising non-invasive method in evaluating CFR. Korean Academy of Medical Sciences 2000-04 /pmc/articles/PMC3054624/ /pubmed/10803688 Text en
spellingShingle Research Article
Kim, S. M.
Shim, W. J.
Lim, H. E.
Hwang, G. S.
Song, W. H.
Lim, D. S.
Kim, Y. H.
Seo, H. S.
Oh, D. J.
Ro, Y. M.
Assessment of coronary flow reserve with transthoracic Doppler echocardiography: comparison with intracoronary Doppler method.
title Assessment of coronary flow reserve with transthoracic Doppler echocardiography: comparison with intracoronary Doppler method.
title_full Assessment of coronary flow reserve with transthoracic Doppler echocardiography: comparison with intracoronary Doppler method.
title_fullStr Assessment of coronary flow reserve with transthoracic Doppler echocardiography: comparison with intracoronary Doppler method.
title_full_unstemmed Assessment of coronary flow reserve with transthoracic Doppler echocardiography: comparison with intracoronary Doppler method.
title_short Assessment of coronary flow reserve with transthoracic Doppler echocardiography: comparison with intracoronary Doppler method.
title_sort assessment of coronary flow reserve with transthoracic doppler echocardiography: comparison with intracoronary doppler method.
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3054624/
https://www.ncbi.nlm.nih.gov/pubmed/10803688
work_keys_str_mv AT kimsm assessmentofcoronaryflowreservewithtransthoracicdopplerechocardiographycomparisonwithintracoronarydopplermethod
AT shimwj assessmentofcoronaryflowreservewithtransthoracicdopplerechocardiographycomparisonwithintracoronarydopplermethod
AT limhe assessmentofcoronaryflowreservewithtransthoracicdopplerechocardiographycomparisonwithintracoronarydopplermethod
AT hwanggs assessmentofcoronaryflowreservewithtransthoracicdopplerechocardiographycomparisonwithintracoronarydopplermethod
AT songwh assessmentofcoronaryflowreservewithtransthoracicdopplerechocardiographycomparisonwithintracoronarydopplermethod
AT limds assessmentofcoronaryflowreservewithtransthoracicdopplerechocardiographycomparisonwithintracoronarydopplermethod
AT kimyh assessmentofcoronaryflowreservewithtransthoracicdopplerechocardiographycomparisonwithintracoronarydopplermethod
AT seohs assessmentofcoronaryflowreservewithtransthoracicdopplerechocardiographycomparisonwithintracoronarydopplermethod
AT ohdj assessmentofcoronaryflowreservewithtransthoracicdopplerechocardiographycomparisonwithintracoronarydopplermethod
AT roym assessmentofcoronaryflowreservewithtransthoracicdopplerechocardiographycomparisonwithintracoronarydopplermethod