Cargando…
Assessment of coronary flow reserve with transthoracic Doppler echocardiography: comparison with intracoronary Doppler method.
To evaluate the feasibility and usefulness of transthoracic Doppler echocardiography (TTDE) as a non-invasive method in recording distal anterior descending (LAD) coronary flow velocity, we compared coronary flow reserve (CFR) measured by TTDE with measurements by intracoronary Doppler wire (ICDW)....
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Medical Sciences
2000
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3054624/ https://www.ncbi.nlm.nih.gov/pubmed/10803688 |
_version_ | 1782199991011377152 |
---|---|
author | Kim, S. M. Shim, W. J. Lim, H. E. Hwang, G. S. Song, W. H. Lim, D. S. Kim, Y. H. Seo, H. S. Oh, D. J. Ro, Y. M. |
author_facet | Kim, S. M. Shim, W. J. Lim, H. E. Hwang, G. S. Song, W. H. Lim, D. S. Kim, Y. H. Seo, H. S. Oh, D. J. Ro, Y. M. |
author_sort | Kim, S. M. |
collection | PubMed |
description | To evaluate the feasibility and usefulness of transthoracic Doppler echocardiography (TTDE) as a non-invasive method in recording distal anterior descending (LAD) coronary flow velocity, we compared coronary flow reserve (CFR) measured by TTDE with measurements by intracoronary Doppler wire (ICDW). Twenty-one patients without LAD stenosis were studied. ICDW performed at baseline and after intracoronary injection of 18 microg adenosine. TTDE was performed at baseline and after intravenous adenosine (140 microg/kgmin for 2 min). Adequate Doppler recordings of coronary flow velocities during systole were obtained in 14 of 21 study patients (67%) and during diastole in 17 (81%) patients. Baseline and hyperemic peak diastolic flow velocities measured by TTDE were significantly smaller than those obtained by ICDW (p<0.05). However, diminishing trends of diastolic and systolic velocity ratio after hyperemia were similarly observed in both methods. CFR obtained by TTDE (3.0+/-0.5), was higher than the value calculated by ICDW (2.5+/-0.4). There were significant correlations between the values obtained by the two methods (r=0.72, p<0.01). It is concluded that TTDE is a feasible method in measuring coronary flow velocity and appears to be a promising non-invasive method in evaluating CFR. |
format | Text |
id | pubmed-3054624 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2000 |
publisher | Korean Academy of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-30546242011-03-15 Assessment of coronary flow reserve with transthoracic Doppler echocardiography: comparison with intracoronary Doppler method. Kim, S. M. Shim, W. J. Lim, H. E. Hwang, G. S. Song, W. H. Lim, D. S. Kim, Y. H. Seo, H. S. Oh, D. J. Ro, Y. M. J Korean Med Sci Research Article To evaluate the feasibility and usefulness of transthoracic Doppler echocardiography (TTDE) as a non-invasive method in recording distal anterior descending (LAD) coronary flow velocity, we compared coronary flow reserve (CFR) measured by TTDE with measurements by intracoronary Doppler wire (ICDW). Twenty-one patients without LAD stenosis were studied. ICDW performed at baseline and after intracoronary injection of 18 microg adenosine. TTDE was performed at baseline and after intravenous adenosine (140 microg/kgmin for 2 min). Adequate Doppler recordings of coronary flow velocities during systole were obtained in 14 of 21 study patients (67%) and during diastole in 17 (81%) patients. Baseline and hyperemic peak diastolic flow velocities measured by TTDE were significantly smaller than those obtained by ICDW (p<0.05). However, diminishing trends of diastolic and systolic velocity ratio after hyperemia were similarly observed in both methods. CFR obtained by TTDE (3.0+/-0.5), was higher than the value calculated by ICDW (2.5+/-0.4). There were significant correlations between the values obtained by the two methods (r=0.72, p<0.01). It is concluded that TTDE is a feasible method in measuring coronary flow velocity and appears to be a promising non-invasive method in evaluating CFR. Korean Academy of Medical Sciences 2000-04 /pmc/articles/PMC3054624/ /pubmed/10803688 Text en |
spellingShingle | Research Article Kim, S. M. Shim, W. J. Lim, H. E. Hwang, G. S. Song, W. H. Lim, D. S. Kim, Y. H. Seo, H. S. Oh, D. J. Ro, Y. M. Assessment of coronary flow reserve with transthoracic Doppler echocardiography: comparison with intracoronary Doppler method. |
title | Assessment of coronary flow reserve with transthoracic Doppler echocardiography: comparison with intracoronary Doppler method. |
title_full | Assessment of coronary flow reserve with transthoracic Doppler echocardiography: comparison with intracoronary Doppler method. |
title_fullStr | Assessment of coronary flow reserve with transthoracic Doppler echocardiography: comparison with intracoronary Doppler method. |
title_full_unstemmed | Assessment of coronary flow reserve with transthoracic Doppler echocardiography: comparison with intracoronary Doppler method. |
title_short | Assessment of coronary flow reserve with transthoracic Doppler echocardiography: comparison with intracoronary Doppler method. |
title_sort | assessment of coronary flow reserve with transthoracic doppler echocardiography: comparison with intracoronary doppler method. |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3054624/ https://www.ncbi.nlm.nih.gov/pubmed/10803688 |
work_keys_str_mv | AT kimsm assessmentofcoronaryflowreservewithtransthoracicdopplerechocardiographycomparisonwithintracoronarydopplermethod AT shimwj assessmentofcoronaryflowreservewithtransthoracicdopplerechocardiographycomparisonwithintracoronarydopplermethod AT limhe assessmentofcoronaryflowreservewithtransthoracicdopplerechocardiographycomparisonwithintracoronarydopplermethod AT hwanggs assessmentofcoronaryflowreservewithtransthoracicdopplerechocardiographycomparisonwithintracoronarydopplermethod AT songwh assessmentofcoronaryflowreservewithtransthoracicdopplerechocardiographycomparisonwithintracoronarydopplermethod AT limds assessmentofcoronaryflowreservewithtransthoracicdopplerechocardiographycomparisonwithintracoronarydopplermethod AT kimyh assessmentofcoronaryflowreservewithtransthoracicdopplerechocardiographycomparisonwithintracoronarydopplermethod AT seohs assessmentofcoronaryflowreservewithtransthoracicdopplerechocardiographycomparisonwithintracoronarydopplermethod AT ohdj assessmentofcoronaryflowreservewithtransthoracicdopplerechocardiographycomparisonwithintracoronarydopplermethod AT roym assessmentofcoronaryflowreservewithtransthoracicdopplerechocardiographycomparisonwithintracoronarydopplermethod |