The flow rate of the elastomeric balloon infusor is influenced by the internal pressure of the infusor.

The purpose of this study was to evaluate the flow rate of elastomeric balloon infusor composed of rubber or silicone materials. Two models were studied: the Baxter Twoday Infusor and Advance Silicone Infusor. Each infusion device has a preset flow rate of 2 mL/hr. Fifteen units of each device were...

Descripción completa

Detalles Bibliográficos
Autores principales: Chung, I. S., Cho, H. S., Kim, J. A., Lee, K. H.
Formato: Texto
Lenguaje:English
Publicado: Korean Academy of Medical Sciences 2001
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3054806/
https://www.ncbi.nlm.nih.gov/pubmed/11748348
_version_ 1782200035350413312
author Chung, I. S.
Cho, H. S.
Kim, J. A.
Lee, K. H.
author_facet Chung, I. S.
Cho, H. S.
Kim, J. A.
Lee, K. H.
author_sort Chung, I. S.
collection PubMed
description The purpose of this study was to evaluate the flow rate of elastomeric balloon infusor composed of rubber or silicone materials. Two models were studied: the Baxter Twoday Infusor and Advance Silicone Infusor. Each infusion device has a preset flow rate of 2 mL/hr. Fifteen units of each device were filled with 100 mL of normal saline. The flow rate was measured gravimetically using an electronic balance. The internal pressure of the balloon infusor was measured with a Digital pressure meter via the pressure transducer. The monitored internal pressure of the two kinds of infusor was not maintained uniformly during the entire delivery period, which was divided into 3 phases: the phase of decreasing, maintained, and increasing pressure during the delivery of drug. Both devices initially infused at a relatively high rate, followed by a somewhat steady flow rate. The flow rate distinctly increased in the small residual volume. The flow rate of the balloon infusor used in this study was not sustained uniformly during the entire delivery period and was in proportion to the internal pressure of the infusor regardless of the materials.
format Text
id pubmed-3054806
institution National Center for Biotechnology Information
language English
publishDate 2001
publisher Korean Academy of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-30548062011-03-15 The flow rate of the elastomeric balloon infusor is influenced by the internal pressure of the infusor. Chung, I. S. Cho, H. S. Kim, J. A. Lee, K. H. J Korean Med Sci Research Article The purpose of this study was to evaluate the flow rate of elastomeric balloon infusor composed of rubber or silicone materials. Two models were studied: the Baxter Twoday Infusor and Advance Silicone Infusor. Each infusion device has a preset flow rate of 2 mL/hr. Fifteen units of each device were filled with 100 mL of normal saline. The flow rate was measured gravimetically using an electronic balance. The internal pressure of the balloon infusor was measured with a Digital pressure meter via the pressure transducer. The monitored internal pressure of the two kinds of infusor was not maintained uniformly during the entire delivery period, which was divided into 3 phases: the phase of decreasing, maintained, and increasing pressure during the delivery of drug. Both devices initially infused at a relatively high rate, followed by a somewhat steady flow rate. The flow rate distinctly increased in the small residual volume. The flow rate of the balloon infusor used in this study was not sustained uniformly during the entire delivery period and was in proportion to the internal pressure of the infusor regardless of the materials. Korean Academy of Medical Sciences 2001-12 /pmc/articles/PMC3054806/ /pubmed/11748348 Text en
spellingShingle Research Article
Chung, I. S.
Cho, H. S.
Kim, J. A.
Lee, K. H.
The flow rate of the elastomeric balloon infusor is influenced by the internal pressure of the infusor.
title The flow rate of the elastomeric balloon infusor is influenced by the internal pressure of the infusor.
title_full The flow rate of the elastomeric balloon infusor is influenced by the internal pressure of the infusor.
title_fullStr The flow rate of the elastomeric balloon infusor is influenced by the internal pressure of the infusor.
title_full_unstemmed The flow rate of the elastomeric balloon infusor is influenced by the internal pressure of the infusor.
title_short The flow rate of the elastomeric balloon infusor is influenced by the internal pressure of the infusor.
title_sort flow rate of the elastomeric balloon infusor is influenced by the internal pressure of the infusor.
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3054806/
https://www.ncbi.nlm.nih.gov/pubmed/11748348
work_keys_str_mv AT chungis theflowrateoftheelastomericballooninfusorisinfluencedbytheinternalpressureoftheinfusor
AT chohs theflowrateoftheelastomericballooninfusorisinfluencedbytheinternalpressureoftheinfusor
AT kimja theflowrateoftheelastomericballooninfusorisinfluencedbytheinternalpressureoftheinfusor
AT leekh theflowrateoftheelastomericballooninfusorisinfluencedbytheinternalpressureoftheinfusor
AT chungis flowrateoftheelastomericballooninfusorisinfluencedbytheinternalpressureoftheinfusor
AT chohs flowrateoftheelastomericballooninfusorisinfluencedbytheinternalpressureoftheinfusor
AT kimja flowrateoftheelastomericballooninfusorisinfluencedbytheinternalpressureoftheinfusor
AT leekh flowrateoftheelastomericballooninfusorisinfluencedbytheinternalpressureoftheinfusor