Cargando…
Revision of a nonunited subtrochanteric femoral fracture around a failed intramedullary nail with the use of RIA products, BMP-7 and hydroxyapatite: a case report
INTRODUCTION: Femoral subtrochanteric fractures are commonly treated using intramedullary devices. Failure of the implant and subsequent nonunion is still an issue, however, and limited evidence exists regarding the most appropriate treatment. CASE PRESENTATION: We report the case of an 80-year-old...
Autores principales: | Tzioupis, Christopher, Panteliadis, Pavlos, Gamie, Zakareya, Tsiridis, Eleftherios |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3055835/ https://www.ncbi.nlm.nih.gov/pubmed/21362192 http://dx.doi.org/10.1186/1752-1947-5-87 |
Ejemplares similares
-
Reconstruction intramedullary nailing for a failed subtrochanteric Seinsheimer type IIB fracture: a case report
por: Wang, Fei, et al.
Publicado: (2023) -
Outcomes of Intramedullary Nailing with Cerclage Wiring in Subtrochanteric Femoral Fractures
por: Mehta, Nisarg J, et al.
Publicado: (2019) -
Tibiotarsal Arthrodesis with Retrograde Intramedullary Nail and RIA Graft: A Salvage Technique
por: Salvo, Giancarlo, et al.
Publicado: (2023) -
Nonunited humerus shaft fractures treated by external fixator augmented by intramedullary rod
por: El-Rosasy, Mahmoud A
Publicado: (2012) -
Risk factors for nonunion after intramedullary nailing of subtrochanteric femoral fractures
por: Krappinger, Dietmar, et al.
Publicado: (2019)