Cargando…

Accumulation and transport of microbial-size particles in a pressure protected model burn unit: CFD simulations and experimental evidence

BACKGROUND: Controlling airborne contamination is of major importance in burn units because of the high susceptibility of burned patients to infections and the unique environmental conditions that can accentuate the infection risk. In particular the required elevated temperatures in the patient room...

Descripción completa

Detalles Bibliográficos
Autores principales: Beauchêne, Christian, Laudinet, Nicolas, Choukri, Firas, Rousset, Jean-Luc, Benhamadouche, Sofiane, Larbre, Juliette, Chaouat, Marc, Benbunan, Marc, Mimoun, Maurice, Lajonchère, Jean-Patrick, Bergeron, Vance, Derouin, Francis
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3056797/
https://www.ncbi.nlm.nih.gov/pubmed/21371304
http://dx.doi.org/10.1186/1471-2334-11-58
_version_ 1782200244876869632
author Beauchêne, Christian
Laudinet, Nicolas
Choukri, Firas
Rousset, Jean-Luc
Benhamadouche, Sofiane
Larbre, Juliette
Chaouat, Marc
Benbunan, Marc
Mimoun, Maurice
Lajonchère, Jean-Patrick
Bergeron, Vance
Derouin, Francis
author_facet Beauchêne, Christian
Laudinet, Nicolas
Choukri, Firas
Rousset, Jean-Luc
Benhamadouche, Sofiane
Larbre, Juliette
Chaouat, Marc
Benbunan, Marc
Mimoun, Maurice
Lajonchère, Jean-Patrick
Bergeron, Vance
Derouin, Francis
author_sort Beauchêne, Christian
collection PubMed
description BACKGROUND: Controlling airborne contamination is of major importance in burn units because of the high susceptibility of burned patients to infections and the unique environmental conditions that can accentuate the infection risk. In particular the required elevated temperatures in the patient room can create thermal convection flows which can transport airborne contaminates throughout the unit. In order to estimate this risk and optimize the design of an intensive care room intended to host severely burned patients, we have relied on a computational fluid dynamic methodology (CFD). METHODS: The study was carried out in 4 steps: i) patient room design, ii) CFD simulations of patient room design to model air flows throughout the patient room, adjacent anterooms and the corridor, iii) construction of a prototype room and subsequent experimental studies to characterize its performance iv) qualitative comparison of the tendencies between CFD prediction and experimental results. The Electricité De France (EDF) open-source software Code_Saturne(® )(http://www.code-saturne.org) was used and CFD simulations were conducted with an hexahedral mesh containing about 300 000 computational cells. The computational domain included the treatment room and two anterooms including equipment, staff and patient. Experiments with inert aerosol particles followed by time-resolved particle counting were conducted in the prototype room for comparison with the CFD observations. RESULTS: We found that thermal convection can create contaminated zones near the ceiling of the room, which can subsequently lead to contaminate transfer in adjacent rooms. Experimental confirmation of these phenomena agreed well with CFD predictions and showed that particles greater than one micron (i.e. bacterial or fungal spore sizes) can be influenced by these thermally induced flows. When the temperature difference between rooms was 7°C, a significant contamination transfer was observed to enter into the positive pressure room when the access door was opened, while 2°C had little effect. Based on these findings the constructed burn unit was outfitted with supplemental air exhaust ducts over the doors to compensate for the thermal convective flows. CONCLUSIONS: CFD simulations proved to be a particularly useful tool for the design and optimization of a burn unit treatment room. Our results, which have been confirmed qualitatively by experimental investigation, stressed that airborne transfer of microbial size particles via thermal convection flows are able to bypass the protective overpressure in the patient room, which can represent a potential risk of cross contamination between rooms in protected environments.
format Text
id pubmed-3056797
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-30567972011-03-15 Accumulation and transport of microbial-size particles in a pressure protected model burn unit: CFD simulations and experimental evidence Beauchêne, Christian Laudinet, Nicolas Choukri, Firas Rousset, Jean-Luc Benhamadouche, Sofiane Larbre, Juliette Chaouat, Marc Benbunan, Marc Mimoun, Maurice Lajonchère, Jean-Patrick Bergeron, Vance Derouin, Francis BMC Infect Dis Research Article BACKGROUND: Controlling airborne contamination is of major importance in burn units because of the high susceptibility of burned patients to infections and the unique environmental conditions that can accentuate the infection risk. In particular the required elevated temperatures in the patient room can create thermal convection flows which can transport airborne contaminates throughout the unit. In order to estimate this risk and optimize the design of an intensive care room intended to host severely burned patients, we have relied on a computational fluid dynamic methodology (CFD). METHODS: The study was carried out in 4 steps: i) patient room design, ii) CFD simulations of patient room design to model air flows throughout the patient room, adjacent anterooms and the corridor, iii) construction of a prototype room and subsequent experimental studies to characterize its performance iv) qualitative comparison of the tendencies between CFD prediction and experimental results. The Electricité De France (EDF) open-source software Code_Saturne(® )(http://www.code-saturne.org) was used and CFD simulations were conducted with an hexahedral mesh containing about 300 000 computational cells. The computational domain included the treatment room and two anterooms including equipment, staff and patient. Experiments with inert aerosol particles followed by time-resolved particle counting were conducted in the prototype room for comparison with the CFD observations. RESULTS: We found that thermal convection can create contaminated zones near the ceiling of the room, which can subsequently lead to contaminate transfer in adjacent rooms. Experimental confirmation of these phenomena agreed well with CFD predictions and showed that particles greater than one micron (i.e. bacterial or fungal spore sizes) can be influenced by these thermally induced flows. When the temperature difference between rooms was 7°C, a significant contamination transfer was observed to enter into the positive pressure room when the access door was opened, while 2°C had little effect. Based on these findings the constructed burn unit was outfitted with supplemental air exhaust ducts over the doors to compensate for the thermal convective flows. CONCLUSIONS: CFD simulations proved to be a particularly useful tool for the design and optimization of a burn unit treatment room. Our results, which have been confirmed qualitatively by experimental investigation, stressed that airborne transfer of microbial size particles via thermal convection flows are able to bypass the protective overpressure in the patient room, which can represent a potential risk of cross contamination between rooms in protected environments. BioMed Central 2011-03-03 /pmc/articles/PMC3056797/ /pubmed/21371304 http://dx.doi.org/10.1186/1471-2334-11-58 Text en Copyright ©2011 Beauchêne et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Beauchêne, Christian
Laudinet, Nicolas
Choukri, Firas
Rousset, Jean-Luc
Benhamadouche, Sofiane
Larbre, Juliette
Chaouat, Marc
Benbunan, Marc
Mimoun, Maurice
Lajonchère, Jean-Patrick
Bergeron, Vance
Derouin, Francis
Accumulation and transport of microbial-size particles in a pressure protected model burn unit: CFD simulations and experimental evidence
title Accumulation and transport of microbial-size particles in a pressure protected model burn unit: CFD simulations and experimental evidence
title_full Accumulation and transport of microbial-size particles in a pressure protected model burn unit: CFD simulations and experimental evidence
title_fullStr Accumulation and transport of microbial-size particles in a pressure protected model burn unit: CFD simulations and experimental evidence
title_full_unstemmed Accumulation and transport of microbial-size particles in a pressure protected model burn unit: CFD simulations and experimental evidence
title_short Accumulation and transport of microbial-size particles in a pressure protected model burn unit: CFD simulations and experimental evidence
title_sort accumulation and transport of microbial-size particles in a pressure protected model burn unit: cfd simulations and experimental evidence
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3056797/
https://www.ncbi.nlm.nih.gov/pubmed/21371304
http://dx.doi.org/10.1186/1471-2334-11-58
work_keys_str_mv AT beauchenechristian accumulationandtransportofmicrobialsizeparticlesinapressureprotectedmodelburnunitcfdsimulationsandexperimentalevidence
AT laudinetnicolas accumulationandtransportofmicrobialsizeparticlesinapressureprotectedmodelburnunitcfdsimulationsandexperimentalevidence
AT choukrifiras accumulationandtransportofmicrobialsizeparticlesinapressureprotectedmodelburnunitcfdsimulationsandexperimentalevidence
AT roussetjeanluc accumulationandtransportofmicrobialsizeparticlesinapressureprotectedmodelburnunitcfdsimulationsandexperimentalevidence
AT benhamadouchesofiane accumulationandtransportofmicrobialsizeparticlesinapressureprotectedmodelburnunitcfdsimulationsandexperimentalevidence
AT larbrejuliette accumulationandtransportofmicrobialsizeparticlesinapressureprotectedmodelburnunitcfdsimulationsandexperimentalevidence
AT chaouatmarc accumulationandtransportofmicrobialsizeparticlesinapressureprotectedmodelburnunitcfdsimulationsandexperimentalevidence
AT benbunanmarc accumulationandtransportofmicrobialsizeparticlesinapressureprotectedmodelburnunitcfdsimulationsandexperimentalevidence
AT mimounmaurice accumulationandtransportofmicrobialsizeparticlesinapressureprotectedmodelburnunitcfdsimulationsandexperimentalevidence
AT lajoncherejeanpatrick accumulationandtransportofmicrobialsizeparticlesinapressureprotectedmodelburnunitcfdsimulationsandexperimentalevidence
AT bergeronvance accumulationandtransportofmicrobialsizeparticlesinapressureprotectedmodelburnunitcfdsimulationsandexperimentalevidence
AT derouinfrancis accumulationandtransportofmicrobialsizeparticlesinapressureprotectedmodelburnunitcfdsimulationsandexperimentalevidence