Cargando…
Treatment Planning and Volumetric Response Assessment for Yttrium-90 Radioembolization: Semiautomated Determination of Liver Volume and Volume of Tumor Necrosis in Patients with Hepatic Malignancy
PURPOSE: The primary purpose of this study was to demonstrate intraobserver/interobserver reproducibility for novel semiautomated measurements of hepatic volume used for Yttrium-90 dose calculations as well as whole-liver and necrotic-liver (hypodense/nonenhancing) tumor volume after radioembolizati...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Springer-Verlag
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3058556/ https://www.ncbi.nlm.nih.gov/pubmed/20683722 http://dx.doi.org/10.1007/s00270-010-9938-3 |
_version_ | 1782200372405731328 |
---|---|
author | Monsky, Wayne L. Garza, Armando S. Kim, Isaac Loh, Shaun Lin, Tzu-Chun Li, Chin-Shang Fisher, Jerron Sandhu, Parmbir Sidhar, Vishal Chaudhari, Abhijit J. Lin, Frank Deutsch, Larry-Stuart Badawi, Ramsey D. |
author_facet | Monsky, Wayne L. Garza, Armando S. Kim, Isaac Loh, Shaun Lin, Tzu-Chun Li, Chin-Shang Fisher, Jerron Sandhu, Parmbir Sidhar, Vishal Chaudhari, Abhijit J. Lin, Frank Deutsch, Larry-Stuart Badawi, Ramsey D. |
author_sort | Monsky, Wayne L. |
collection | PubMed |
description | PURPOSE: The primary purpose of this study was to demonstrate intraobserver/interobserver reproducibility for novel semiautomated measurements of hepatic volume used for Yttrium-90 dose calculations as well as whole-liver and necrotic-liver (hypodense/nonenhancing) tumor volume after radioembolization. The secondary aim was to provide initial comparisons of tumor volumetric measurements with linear measurements, as defined by Response Evaluation Criteria in Solid Tumors criteria, and survival outcomes. METHODS: Between 2006 and 2009, 23 consecutive radioembolization procedures were performed for 14 cases of hepatocellular carcinoma and 9 cases of hepatic metastases. Baseline and follow-up computed tomography obtained 1 month after treatment were retrospectively analyzed. Three observers measured liver, whole-tumor, and tumor-necrosis volumes twice using semiautomated software. RESULTS: Good intraobserver/interobserver reproducibility was demonstrated (intraclass correlation [ICC] > 0.9) for tumor and liver volumes. Semiautomated measurements of liver volumes were statistically similar to those obtained with manual tracing (ICC = 0.868), but they required significantly less time to perform (p < 0.0001, ICC = 0.088). There was a positive association between change in linear tumor measurements and whole-tumor volume (p < 0.0001). However, linear measurements did not correlate with volume of necrosis (p > 0.05). Dose, change in tumor diameters, tumor volume, and necrotic volume did not correlate with survival (p > 0.05 in all instances). However, Kaplan–Meier curves suggest that a >10% increase in necrotic volume correlated with survival (p = 0.0472). CONCLUSION: Semiautomated volumetric analysis of liver, whole-tumor, and tumor-necrosis volume can be performed with good intraobserver/interobserver reproducibility. In this small retrospective study, measurements of tumor necrosis were suggested to correlate with survival. |
format | Text |
id | pubmed-3058556 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Springer-Verlag |
record_format | MEDLINE/PubMed |
spelling | pubmed-30585562011-04-05 Treatment Planning and Volumetric Response Assessment for Yttrium-90 Radioembolization: Semiautomated Determination of Liver Volume and Volume of Tumor Necrosis in Patients with Hepatic Malignancy Monsky, Wayne L. Garza, Armando S. Kim, Isaac Loh, Shaun Lin, Tzu-Chun Li, Chin-Shang Fisher, Jerron Sandhu, Parmbir Sidhar, Vishal Chaudhari, Abhijit J. Lin, Frank Deutsch, Larry-Stuart Badawi, Ramsey D. Cardiovasc Intervent Radiol Clinical Investigation PURPOSE: The primary purpose of this study was to demonstrate intraobserver/interobserver reproducibility for novel semiautomated measurements of hepatic volume used for Yttrium-90 dose calculations as well as whole-liver and necrotic-liver (hypodense/nonenhancing) tumor volume after radioembolization. The secondary aim was to provide initial comparisons of tumor volumetric measurements with linear measurements, as defined by Response Evaluation Criteria in Solid Tumors criteria, and survival outcomes. METHODS: Between 2006 and 2009, 23 consecutive radioembolization procedures were performed for 14 cases of hepatocellular carcinoma and 9 cases of hepatic metastases. Baseline and follow-up computed tomography obtained 1 month after treatment were retrospectively analyzed. Three observers measured liver, whole-tumor, and tumor-necrosis volumes twice using semiautomated software. RESULTS: Good intraobserver/interobserver reproducibility was demonstrated (intraclass correlation [ICC] > 0.9) for tumor and liver volumes. Semiautomated measurements of liver volumes were statistically similar to those obtained with manual tracing (ICC = 0.868), but they required significantly less time to perform (p < 0.0001, ICC = 0.088). There was a positive association between change in linear tumor measurements and whole-tumor volume (p < 0.0001). However, linear measurements did not correlate with volume of necrosis (p > 0.05). Dose, change in tumor diameters, tumor volume, and necrotic volume did not correlate with survival (p > 0.05 in all instances). However, Kaplan–Meier curves suggest that a >10% increase in necrotic volume correlated with survival (p = 0.0472). CONCLUSION: Semiautomated volumetric analysis of liver, whole-tumor, and tumor-necrosis volume can be performed with good intraobserver/interobserver reproducibility. In this small retrospective study, measurements of tumor necrosis were suggested to correlate with survival. Springer-Verlag 2010-08-04 2011 /pmc/articles/PMC3058556/ /pubmed/20683722 http://dx.doi.org/10.1007/s00270-010-9938-3 Text en © The Author(s) 2010 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited. |
spellingShingle | Clinical Investigation Monsky, Wayne L. Garza, Armando S. Kim, Isaac Loh, Shaun Lin, Tzu-Chun Li, Chin-Shang Fisher, Jerron Sandhu, Parmbir Sidhar, Vishal Chaudhari, Abhijit J. Lin, Frank Deutsch, Larry-Stuart Badawi, Ramsey D. Treatment Planning and Volumetric Response Assessment for Yttrium-90 Radioembolization: Semiautomated Determination of Liver Volume and Volume of Tumor Necrosis in Patients with Hepatic Malignancy |
title | Treatment Planning and Volumetric Response Assessment for Yttrium-90 Radioembolization: Semiautomated Determination of Liver Volume and Volume of Tumor Necrosis in Patients with Hepatic Malignancy |
title_full | Treatment Planning and Volumetric Response Assessment for Yttrium-90 Radioembolization: Semiautomated Determination of Liver Volume and Volume of Tumor Necrosis in Patients with Hepatic Malignancy |
title_fullStr | Treatment Planning and Volumetric Response Assessment for Yttrium-90 Radioembolization: Semiautomated Determination of Liver Volume and Volume of Tumor Necrosis in Patients with Hepatic Malignancy |
title_full_unstemmed | Treatment Planning and Volumetric Response Assessment for Yttrium-90 Radioembolization: Semiautomated Determination of Liver Volume and Volume of Tumor Necrosis in Patients with Hepatic Malignancy |
title_short | Treatment Planning and Volumetric Response Assessment for Yttrium-90 Radioembolization: Semiautomated Determination of Liver Volume and Volume of Tumor Necrosis in Patients with Hepatic Malignancy |
title_sort | treatment planning and volumetric response assessment for yttrium-90 radioembolization: semiautomated determination of liver volume and volume of tumor necrosis in patients with hepatic malignancy |
topic | Clinical Investigation |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3058556/ https://www.ncbi.nlm.nih.gov/pubmed/20683722 http://dx.doi.org/10.1007/s00270-010-9938-3 |
work_keys_str_mv | AT monskywaynel treatmentplanningandvolumetricresponseassessmentforyttrium90radioembolizationsemiautomateddeterminationoflivervolumeandvolumeoftumornecrosisinpatientswithhepaticmalignancy AT garzaarmandos treatmentplanningandvolumetricresponseassessmentforyttrium90radioembolizationsemiautomateddeterminationoflivervolumeandvolumeoftumornecrosisinpatientswithhepaticmalignancy AT kimisaac treatmentplanningandvolumetricresponseassessmentforyttrium90radioembolizationsemiautomateddeterminationoflivervolumeandvolumeoftumornecrosisinpatientswithhepaticmalignancy AT lohshaun treatmentplanningandvolumetricresponseassessmentforyttrium90radioembolizationsemiautomateddeterminationoflivervolumeandvolumeoftumornecrosisinpatientswithhepaticmalignancy AT lintzuchun treatmentplanningandvolumetricresponseassessmentforyttrium90radioembolizationsemiautomateddeterminationoflivervolumeandvolumeoftumornecrosisinpatientswithhepaticmalignancy AT lichinshang treatmentplanningandvolumetricresponseassessmentforyttrium90radioembolizationsemiautomateddeterminationoflivervolumeandvolumeoftumornecrosisinpatientswithhepaticmalignancy AT fisherjerron treatmentplanningandvolumetricresponseassessmentforyttrium90radioembolizationsemiautomateddeterminationoflivervolumeandvolumeoftumornecrosisinpatientswithhepaticmalignancy AT sandhuparmbir treatmentplanningandvolumetricresponseassessmentforyttrium90radioembolizationsemiautomateddeterminationoflivervolumeandvolumeoftumornecrosisinpatientswithhepaticmalignancy AT sidharvishal treatmentplanningandvolumetricresponseassessmentforyttrium90radioembolizationsemiautomateddeterminationoflivervolumeandvolumeoftumornecrosisinpatientswithhepaticmalignancy AT chaudhariabhijitj treatmentplanningandvolumetricresponseassessmentforyttrium90radioembolizationsemiautomateddeterminationoflivervolumeandvolumeoftumornecrosisinpatientswithhepaticmalignancy AT linfrank treatmentplanningandvolumetricresponseassessmentforyttrium90radioembolizationsemiautomateddeterminationoflivervolumeandvolumeoftumornecrosisinpatientswithhepaticmalignancy AT deutschlarrystuart treatmentplanningandvolumetricresponseassessmentforyttrium90radioembolizationsemiautomateddeterminationoflivervolumeandvolumeoftumornecrosisinpatientswithhepaticmalignancy AT badawiramseyd treatmentplanningandvolumetricresponseassessmentforyttrium90radioembolizationsemiautomateddeterminationoflivervolumeandvolumeoftumornecrosisinpatientswithhepaticmalignancy |