Use of embedded strain gages for the in-vitro study of proximal tibial cancellous bone deformation during knee flexion-extension movement: development, reproducibility and preliminary results of feasibility after frontal low femoral osteotomy

BACKGROUND: This paper reports the development of an in-vitro technique allowing quantification of relative (not absolute) deformations measured at the level of the cancellous bone of the tibial proximal epiphysis (CB(TPE)) during knee flexion-extension. This method has been developed to allow a fut...

Descripción completa

Detalles Bibliográficos
Autores principales: Sobczak, Stéphane, Salvia, Patrick, Dugailly, Pierre-Michel, Lefèvre, Philippe, Feipel, Véronique, Van Sint Jan, Serge, Rooze, Marcel
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3059297/
https://www.ncbi.nlm.nih.gov/pubmed/21371297
http://dx.doi.org/10.1186/1749-799X-6-12
_version_ 1782200402094063616
author Sobczak, Stéphane
Salvia, Patrick
Dugailly, Pierre-Michel
Lefèvre, Philippe
Feipel, Véronique
Van Sint Jan, Serge
Rooze, Marcel
author_facet Sobczak, Stéphane
Salvia, Patrick
Dugailly, Pierre-Michel
Lefèvre, Philippe
Feipel, Véronique
Van Sint Jan, Serge
Rooze, Marcel
author_sort Sobczak, Stéphane
collection PubMed
description BACKGROUND: This paper reports the development of an in-vitro technique allowing quantification of relative (not absolute) deformations measured at the level of the cancellous bone of the tibial proximal epiphysis (CB(TPE)) during knee flexion-extension. This method has been developed to allow a future study of the effects of low femoral osteotomies consequence on the CB(TPE). METHODS: Six strain gages were encapsulated in an epoxy resin solution to form, after resin polymerisation, six measurement elements (ME). The latter were inserted into the CB(TPE )of six unembalmed specimens, just below the tibial plateau. Knee motion data were collected by three-dimensional (3D) electrogoniometry during several cycles of knee flexion-extension. Intra- and inter-observer reproducibility was estimated on one specimen for all MEs. Intra-specimen repeatability was calculated to determine specimen's variability and the error of measurement. A varum and valgum chirurgical procedure was realised on another specimen to observed CB(TPE )deformation after these kind of procedure. RESULTS: Average intra-observer variation of the deformation ranged from 8% to 9% (mean coefficient of variation, MCV) respectively for extension and flexion movement. The coefficient of multiple correlations (CMC) ranged from 0.93 to 0.96 for flexion and extension. No phase shift of maximum strain peaks was observed. Inter-observer MCV averaged 23% and 28% for flexion and extension. The CMC were 0.82 and 0.87 respectively for extension and flexion. For the intra-specimen repeatability, the average of mean RMS difference and the mean ICC were calculated only for flexion movement. The mean RMS variability ranged from 7 to 10% and the mean ICC was 0.98 (0.95 - 0.99). A Pearson's correlation coefficient was calculated showing that RMS was independent of signal intensity. For the chirurgical procedure, valgum and varum deviation seems be in agree with the frontal misalignment theory. CONCLUSIONS: Results show that the methodology is reproducible within a range of 10%. This method has been developed to allow analysis the indirect reflect of deformation variations in CB(TPE )before and after distal femoral osteotomies. The first results of the valgum and varum deformation show that our methodology allows this kind of measurement and are encourageant for latter studies. It will therefore allow quantification and enhance the understanding of the effects of this kind of surgery on the CB(TPE )loading.
format Text
id pubmed-3059297
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-30592972011-03-17 Use of embedded strain gages for the in-vitro study of proximal tibial cancellous bone deformation during knee flexion-extension movement: development, reproducibility and preliminary results of feasibility after frontal low femoral osteotomy Sobczak, Stéphane Salvia, Patrick Dugailly, Pierre-Michel Lefèvre, Philippe Feipel, Véronique Van Sint Jan, Serge Rooze, Marcel J Orthop Surg Res Technical Note BACKGROUND: This paper reports the development of an in-vitro technique allowing quantification of relative (not absolute) deformations measured at the level of the cancellous bone of the tibial proximal epiphysis (CB(TPE)) during knee flexion-extension. This method has been developed to allow a future study of the effects of low femoral osteotomies consequence on the CB(TPE). METHODS: Six strain gages were encapsulated in an epoxy resin solution to form, after resin polymerisation, six measurement elements (ME). The latter were inserted into the CB(TPE )of six unembalmed specimens, just below the tibial plateau. Knee motion data were collected by three-dimensional (3D) electrogoniometry during several cycles of knee flexion-extension. Intra- and inter-observer reproducibility was estimated on one specimen for all MEs. Intra-specimen repeatability was calculated to determine specimen's variability and the error of measurement. A varum and valgum chirurgical procedure was realised on another specimen to observed CB(TPE )deformation after these kind of procedure. RESULTS: Average intra-observer variation of the deformation ranged from 8% to 9% (mean coefficient of variation, MCV) respectively for extension and flexion movement. The coefficient of multiple correlations (CMC) ranged from 0.93 to 0.96 for flexion and extension. No phase shift of maximum strain peaks was observed. Inter-observer MCV averaged 23% and 28% for flexion and extension. The CMC were 0.82 and 0.87 respectively for extension and flexion. For the intra-specimen repeatability, the average of mean RMS difference and the mean ICC were calculated only for flexion movement. The mean RMS variability ranged from 7 to 10% and the mean ICC was 0.98 (0.95 - 0.99). A Pearson's correlation coefficient was calculated showing that RMS was independent of signal intensity. For the chirurgical procedure, valgum and varum deviation seems be in agree with the frontal misalignment theory. CONCLUSIONS: Results show that the methodology is reproducible within a range of 10%. This method has been developed to allow analysis the indirect reflect of deformation variations in CB(TPE )before and after distal femoral osteotomies. The first results of the valgum and varum deformation show that our methodology allows this kind of measurement and are encourageant for latter studies. It will therefore allow quantification and enhance the understanding of the effects of this kind of surgery on the CB(TPE )loading. BioMed Central 2011-03-03 /pmc/articles/PMC3059297/ /pubmed/21371297 http://dx.doi.org/10.1186/1749-799X-6-12 Text en Copyright ©2011 Sobczak et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Note
Sobczak, Stéphane
Salvia, Patrick
Dugailly, Pierre-Michel
Lefèvre, Philippe
Feipel, Véronique
Van Sint Jan, Serge
Rooze, Marcel
Use of embedded strain gages for the in-vitro study of proximal tibial cancellous bone deformation during knee flexion-extension movement: development, reproducibility and preliminary results of feasibility after frontal low femoral osteotomy
title Use of embedded strain gages for the in-vitro study of proximal tibial cancellous bone deformation during knee flexion-extension movement: development, reproducibility and preliminary results of feasibility after frontal low femoral osteotomy
title_full Use of embedded strain gages for the in-vitro study of proximal tibial cancellous bone deformation during knee flexion-extension movement: development, reproducibility and preliminary results of feasibility after frontal low femoral osteotomy
title_fullStr Use of embedded strain gages for the in-vitro study of proximal tibial cancellous bone deformation during knee flexion-extension movement: development, reproducibility and preliminary results of feasibility after frontal low femoral osteotomy
title_full_unstemmed Use of embedded strain gages for the in-vitro study of proximal tibial cancellous bone deformation during knee flexion-extension movement: development, reproducibility and preliminary results of feasibility after frontal low femoral osteotomy
title_short Use of embedded strain gages for the in-vitro study of proximal tibial cancellous bone deformation during knee flexion-extension movement: development, reproducibility and preliminary results of feasibility after frontal low femoral osteotomy
title_sort use of embedded strain gages for the in-vitro study of proximal tibial cancellous bone deformation during knee flexion-extension movement: development, reproducibility and preliminary results of feasibility after frontal low femoral osteotomy
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3059297/
https://www.ncbi.nlm.nih.gov/pubmed/21371297
http://dx.doi.org/10.1186/1749-799X-6-12
work_keys_str_mv AT sobczakstephane useofembeddedstraingagesfortheinvitrostudyofproximaltibialcancellousbonedeformationduringkneeflexionextensionmovementdevelopmentreproducibilityandpreliminaryresultsoffeasibilityafterfrontallowfemoralosteotomy
AT salviapatrick useofembeddedstraingagesfortheinvitrostudyofproximaltibialcancellousbonedeformationduringkneeflexionextensionmovementdevelopmentreproducibilityandpreliminaryresultsoffeasibilityafterfrontallowfemoralosteotomy
AT dugaillypierremichel useofembeddedstraingagesfortheinvitrostudyofproximaltibialcancellousbonedeformationduringkneeflexionextensionmovementdevelopmentreproducibilityandpreliminaryresultsoffeasibilityafterfrontallowfemoralosteotomy
AT lefevrephilippe useofembeddedstraingagesfortheinvitrostudyofproximaltibialcancellousbonedeformationduringkneeflexionextensionmovementdevelopmentreproducibilityandpreliminaryresultsoffeasibilityafterfrontallowfemoralosteotomy
AT feipelveronique useofembeddedstraingagesfortheinvitrostudyofproximaltibialcancellousbonedeformationduringkneeflexionextensionmovementdevelopmentreproducibilityandpreliminaryresultsoffeasibilityafterfrontallowfemoralosteotomy
AT vansintjanserge useofembeddedstraingagesfortheinvitrostudyofproximaltibialcancellousbonedeformationduringkneeflexionextensionmovementdevelopmentreproducibilityandpreliminaryresultsoffeasibilityafterfrontallowfemoralosteotomy
AT roozemarcel useofembeddedstraingagesfortheinvitrostudyofproximaltibialcancellousbonedeformationduringkneeflexionextensionmovementdevelopmentreproducibilityandpreliminaryresultsoffeasibilityafterfrontallowfemoralosteotomy