Cargando…

Inter-Device Agreement of Retinal Nerve Fiber Layer Thickness Measurements Using Spectral Domain Cirrus HD OCT

PURPOSE: To assess the inter-device agreement of peripapillary retinal nerve fiber layer (RNFL) thickness measurements by 2 spectral domain Cirrus HD optical coherence tomography (OCT) devices in healthy Korean subjects. METHODS: Eleven eyes of 11 healthy volunteers were enrolled in the present stud...

Descripción completa

Detalles Bibliográficos
Autores principales: Hong, Samin, Kim, Yeongjun, Shim, Jongwoo, Kim, Chan Yun, Seong, Gong Je
Formato: Texto
Lenguaje:English
Publicado: The Korean Ophthalmological Society 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3060386/
https://www.ncbi.nlm.nih.gov/pubmed/21461222
http://dx.doi.org/10.3341/kjo.2011.25.2.105
_version_ 1782200514391310336
author Hong, Samin
Kim, Yeongjun
Shim, Jongwoo
Kim, Chan Yun
Seong, Gong Je
author_facet Hong, Samin
Kim, Yeongjun
Shim, Jongwoo
Kim, Chan Yun
Seong, Gong Je
author_sort Hong, Samin
collection PubMed
description PURPOSE: To assess the inter-device agreement of peripapillary retinal nerve fiber layer (RNFL) thickness measurements by 2 spectral domain Cirrus HD optical coherence tomography (OCT) devices in healthy Korean subjects. METHODS: Eleven eyes of 11 healthy volunteers were enrolled in the present study. Each eye was scanned with the Optic Disc Cube 200 × 200 scan of 2 Cirrus HD OCT devices for peripapillary RNFL thickness calculation. The inter-device agreements of the 2 Cirrus HD OCTs for average, quadrant, and clock-hour RNFL thickness values were determined with Wilcoxon signed rank test, Friedman test, Cronbach's alpha (α), intraclass correlation coefficient (ICC), coefficient of variation (COV), and Bland-Altman plot. RESULTS: The mean age of the participants was 25.82 ± 3.28 years and all had a 0.00 logarithm of the minimum angle of resolution of best-corrected visual acuity. The signal strengths of scans from the 2 Cirrus HD OCT were not significantly different (p = 0.317). The inter-device agreement of average RNFL thickness was excellent (α, 0.940; ICC, 0.945; COV, 2.45 ± 1.52%). However, the agreement of nasal quadrant RNFL thickness was not very good (α, 0.715; ICC, 0.716; COV, 5.72 ± 4.64%). Additionally, on the Bland-Atman plot, the extent of agreement of the 2 Cirrus HD OCTs for RNFL thickness was variable according to scanned sectors. CONCLUSIONS: The inter-device agreement of 2 spectral domain Cirrus HD OCT devices for peripapillary RNFL thickness measurements was generally excellent but variable according to the scanned area. Thus, physicians should consider this fact before judging a change of RNFL thicknesses if they were measured by different OCT devices.
format Text
id pubmed-3060386
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher The Korean Ophthalmological Society
record_format MEDLINE/PubMed
spelling pubmed-30603862011-04-01 Inter-Device Agreement of Retinal Nerve Fiber Layer Thickness Measurements Using Spectral Domain Cirrus HD OCT Hong, Samin Kim, Yeongjun Shim, Jongwoo Kim, Chan Yun Seong, Gong Je Korean J Ophthalmol Original Article PURPOSE: To assess the inter-device agreement of peripapillary retinal nerve fiber layer (RNFL) thickness measurements by 2 spectral domain Cirrus HD optical coherence tomography (OCT) devices in healthy Korean subjects. METHODS: Eleven eyes of 11 healthy volunteers were enrolled in the present study. Each eye was scanned with the Optic Disc Cube 200 × 200 scan of 2 Cirrus HD OCT devices for peripapillary RNFL thickness calculation. The inter-device agreements of the 2 Cirrus HD OCTs for average, quadrant, and clock-hour RNFL thickness values were determined with Wilcoxon signed rank test, Friedman test, Cronbach's alpha (α), intraclass correlation coefficient (ICC), coefficient of variation (COV), and Bland-Altman plot. RESULTS: The mean age of the participants was 25.82 ± 3.28 years and all had a 0.00 logarithm of the minimum angle of resolution of best-corrected visual acuity. The signal strengths of scans from the 2 Cirrus HD OCT were not significantly different (p = 0.317). The inter-device agreement of average RNFL thickness was excellent (α, 0.940; ICC, 0.945; COV, 2.45 ± 1.52%). However, the agreement of nasal quadrant RNFL thickness was not very good (α, 0.715; ICC, 0.716; COV, 5.72 ± 4.64%). Additionally, on the Bland-Atman plot, the extent of agreement of the 2 Cirrus HD OCTs for RNFL thickness was variable according to scanned sectors. CONCLUSIONS: The inter-device agreement of 2 spectral domain Cirrus HD OCT devices for peripapillary RNFL thickness measurements was generally excellent but variable according to the scanned area. Thus, physicians should consider this fact before judging a change of RNFL thicknesses if they were measured by different OCT devices. The Korean Ophthalmological Society 2011-04 2011-03-11 /pmc/articles/PMC3060386/ /pubmed/21461222 http://dx.doi.org/10.3341/kjo.2011.25.2.105 Text en © 2011 The Korean Ophthalmological Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Hong, Samin
Kim, Yeongjun
Shim, Jongwoo
Kim, Chan Yun
Seong, Gong Je
Inter-Device Agreement of Retinal Nerve Fiber Layer Thickness Measurements Using Spectral Domain Cirrus HD OCT
title Inter-Device Agreement of Retinal Nerve Fiber Layer Thickness Measurements Using Spectral Domain Cirrus HD OCT
title_full Inter-Device Agreement of Retinal Nerve Fiber Layer Thickness Measurements Using Spectral Domain Cirrus HD OCT
title_fullStr Inter-Device Agreement of Retinal Nerve Fiber Layer Thickness Measurements Using Spectral Domain Cirrus HD OCT
title_full_unstemmed Inter-Device Agreement of Retinal Nerve Fiber Layer Thickness Measurements Using Spectral Domain Cirrus HD OCT
title_short Inter-Device Agreement of Retinal Nerve Fiber Layer Thickness Measurements Using Spectral Domain Cirrus HD OCT
title_sort inter-device agreement of retinal nerve fiber layer thickness measurements using spectral domain cirrus hd oct
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3060386/
https://www.ncbi.nlm.nih.gov/pubmed/21461222
http://dx.doi.org/10.3341/kjo.2011.25.2.105
work_keys_str_mv AT hongsamin interdeviceagreementofretinalnervefiberlayerthicknessmeasurementsusingspectraldomaincirrushdoct
AT kimyeongjun interdeviceagreementofretinalnervefiberlayerthicknessmeasurementsusingspectraldomaincirrushdoct
AT shimjongwoo interdeviceagreementofretinalnervefiberlayerthicknessmeasurementsusingspectraldomaincirrushdoct
AT kimchanyun interdeviceagreementofretinalnervefiberlayerthicknessmeasurementsusingspectraldomaincirrushdoct
AT seonggongje interdeviceagreementofretinalnervefiberlayerthicknessmeasurementsusingspectraldomaincirrushdoct