Cargando…

False positives in neuroimaging genetics using voxel-based morphometry data

Voxel-wise statistical inference is commonly used to identify significant experimental effects or group differences in both functional and structural studies of the living brain. Tests based on the size of spatially extended clusters of contiguous suprathreshold voxels are also widely used due to th...

Descripción completa

Detalles Bibliográficos
Autores principales: Silver, Matt, Montana, Giovanni, Nichols, Thomas E.
Formato: Texto
Lenguaje:English
Publicado: Academic Press 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3063336/
https://www.ncbi.nlm.nih.gov/pubmed/20849959
http://dx.doi.org/10.1016/j.neuroimage.2010.08.049
_version_ 1782200791086399488
author Silver, Matt
Montana, Giovanni
Nichols, Thomas E.
author_facet Silver, Matt
Montana, Giovanni
Nichols, Thomas E.
author_sort Silver, Matt
collection PubMed
description Voxel-wise statistical inference is commonly used to identify significant experimental effects or group differences in both functional and structural studies of the living brain. Tests based on the size of spatially extended clusters of contiguous suprathreshold voxels are also widely used due to their typically increased statistical power. In “imaging genetics”, such tests are used to identify regions of the brain that are associated with genetic variation. However, concerns have been raised about the adequate control of rejection rates in studies of this type. A previous study tested the effect of a set of ‘null’ SNPs on brain structure and function, and found that false positive rates were well-controlled. However, no similar analysis of false positive rates in an imaging genetic study using cluster size inference has yet been undertaken. We measured false positive rates in an investigation of the effect of 700 pre-selected null SNPs on grey matter volume using voxel-based morphometry (VBM). As VBM data exhibit spatially-varying smoothness, we used both non-stationary and stationary cluster size tests in our analysis. Image and genotype data on 181 subjects with mild cognitive impairment were obtained from the Alzheimer's Disease Neuroimaging Initiative (ADNI). At a nominal significance level of 5%, false positive rates were found to be well-controlled (3.9–5.6%), using a relatively high cluster-forming threshold, α(c) = 0.001, on images smoothed with a 12 mm Gaussian kernel. Tests were however anticonservative at lower cluster-forming thresholds (α(c) = 0.01, 0.05), and for images smoothed using a 6 mm Gaussian kernel. Here false positive rates ranged from 9.8 to 67.6%. In a further analysis, false positive rates using simulated data were observed to be well-controlled across a wide range of conditions. While motivated by imaging genetics, our findings apply to any VBM study, and suggest that parametric cluster size inference should only be used with high cluster-forming thresholds and smoothness. We would advocate the use of nonparametric methods in other cases.
format Text
id pubmed-3063336
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Academic Press
record_format MEDLINE/PubMed
spelling pubmed-30633362011-04-12 False positives in neuroimaging genetics using voxel-based morphometry data Silver, Matt Montana, Giovanni Nichols, Thomas E. Neuroimage Article Voxel-wise statistical inference is commonly used to identify significant experimental effects or group differences in both functional and structural studies of the living brain. Tests based on the size of spatially extended clusters of contiguous suprathreshold voxels are also widely used due to their typically increased statistical power. In “imaging genetics”, such tests are used to identify regions of the brain that are associated with genetic variation. However, concerns have been raised about the adequate control of rejection rates in studies of this type. A previous study tested the effect of a set of ‘null’ SNPs on brain structure and function, and found that false positive rates were well-controlled. However, no similar analysis of false positive rates in an imaging genetic study using cluster size inference has yet been undertaken. We measured false positive rates in an investigation of the effect of 700 pre-selected null SNPs on grey matter volume using voxel-based morphometry (VBM). As VBM data exhibit spatially-varying smoothness, we used both non-stationary and stationary cluster size tests in our analysis. Image and genotype data on 181 subjects with mild cognitive impairment were obtained from the Alzheimer's Disease Neuroimaging Initiative (ADNI). At a nominal significance level of 5%, false positive rates were found to be well-controlled (3.9–5.6%), using a relatively high cluster-forming threshold, α(c) = 0.001, on images smoothed with a 12 mm Gaussian kernel. Tests were however anticonservative at lower cluster-forming thresholds (α(c) = 0.01, 0.05), and for images smoothed using a 6 mm Gaussian kernel. Here false positive rates ranged from 9.8 to 67.6%. In a further analysis, false positive rates using simulated data were observed to be well-controlled across a wide range of conditions. While motivated by imaging genetics, our findings apply to any VBM study, and suggest that parametric cluster size inference should only be used with high cluster-forming thresholds and smoothness. We would advocate the use of nonparametric methods in other cases. Academic Press 2011-01-15 /pmc/articles/PMC3063336/ /pubmed/20849959 http://dx.doi.org/10.1016/j.neuroimage.2010.08.049 Text en © 2011 Elsevier Inc. https://creativecommons.org/licenses/by/3.0/ Open Access under CC BY 3.0 (https://creativecommons.org/licenses/by/3.0/) license
spellingShingle Article
Silver, Matt
Montana, Giovanni
Nichols, Thomas E.
False positives in neuroimaging genetics using voxel-based morphometry data
title False positives in neuroimaging genetics using voxel-based morphometry data
title_full False positives in neuroimaging genetics using voxel-based morphometry data
title_fullStr False positives in neuroimaging genetics using voxel-based morphometry data
title_full_unstemmed False positives in neuroimaging genetics using voxel-based morphometry data
title_short False positives in neuroimaging genetics using voxel-based morphometry data
title_sort false positives in neuroimaging genetics using voxel-based morphometry data
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3063336/
https://www.ncbi.nlm.nih.gov/pubmed/20849959
http://dx.doi.org/10.1016/j.neuroimage.2010.08.049
work_keys_str_mv AT silvermatt falsepositivesinneuroimaginggeneticsusingvoxelbasedmorphometrydata
AT montanagiovanni falsepositivesinneuroimaginggeneticsusingvoxelbasedmorphometrydata
AT nicholsthomase falsepositivesinneuroimaginggeneticsusingvoxelbasedmorphometrydata
AT falsepositivesinneuroimaginggeneticsusingvoxelbasedmorphometrydata