Cargando…
Effect of Using Electric Current during Dentin Bonding Agent Application on Microleakage under Simulated Pulpal Pressure Condition
BACKGROUND: The use of electric current during application of etch-and-rinse adhesive systems has been recently introduced to decrease microleakage. This study investigated the effects of an electric field produced by an experimental device for the application of a two-step etch-and-rinse adhesive o...
Autores principales: | , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3065336/ https://www.ncbi.nlm.nih.gov/pubmed/21448443 |
_version_ | 1782200968031502336 |
---|---|
author | Gharizadeh, Naghmeh Kaviani, Azita Nik, Samaneh |
author_facet | Gharizadeh, Naghmeh Kaviani, Azita Nik, Samaneh |
author_sort | Gharizadeh, Naghmeh |
collection | PubMed |
description | BACKGROUND: The use of electric current during application of etch-and-rinse adhesive systems has been recently introduced to decrease microleakage. This study investigated the effects of an electric field produced by an experimental device for the application of a two-step etch-and-rinse adhesive on moist dentin surface. METHODS: Sixty freshly extracted human premolars were used for this study. In order to simulate real conditions, the pulpal pressure was set to 35 cm H(2)O for all the specimens. The teeth were divided into two groups: in group I, etch-and-rinse system (Single Bond) was applied with electric current while group II, etch-and-rinse system (Single Bond) was applied without electric current. Specimens were prepared for dye penetration test. The data were analyzed using Mann-Whitney U test. RESULTS: The results showed that group I had less microleakage scores compared to group II (P = 0.047). CONCLUSION: Based on the result of this study, it could be concluded that using electric current for applying adhesive systems had a significant effect on reducing microleakage. |
format | Text |
id | pubmed-3065336 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-30653362011-03-29 Effect of Using Electric Current during Dentin Bonding Agent Application on Microleakage under Simulated Pulpal Pressure Condition Gharizadeh, Naghmeh Kaviani, Azita Nik, Samaneh Dent Res J (Isfahan) Original Article BACKGROUND: The use of electric current during application of etch-and-rinse adhesive systems has been recently introduced to decrease microleakage. This study investigated the effects of an electric field produced by an experimental device for the application of a two-step etch-and-rinse adhesive on moist dentin surface. METHODS: Sixty freshly extracted human premolars were used for this study. In order to simulate real conditions, the pulpal pressure was set to 35 cm H(2)O for all the specimens. The teeth were divided into two groups: in group I, etch-and-rinse system (Single Bond) was applied with electric current while group II, etch-and-rinse system (Single Bond) was applied without electric current. Specimens were prepared for dye penetration test. The data were analyzed using Mann-Whitney U test. RESULTS: The results showed that group I had less microleakage scores compared to group II (P = 0.047). CONCLUSION: Based on the result of this study, it could be concluded that using electric current for applying adhesive systems had a significant effect on reducing microleakage. Medknow Publications & Media Pvt Ltd 2010 /pmc/articles/PMC3065336/ /pubmed/21448443 Text en Copyright: © Dental Research Journal http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Gharizadeh, Naghmeh Kaviani, Azita Nik, Samaneh Effect of Using Electric Current during Dentin Bonding Agent Application on Microleakage under Simulated Pulpal Pressure Condition |
title | Effect of Using Electric Current during Dentin Bonding Agent Application on Microleakage under Simulated Pulpal Pressure Condition |
title_full | Effect of Using Electric Current during Dentin Bonding Agent Application on Microleakage under Simulated Pulpal Pressure Condition |
title_fullStr | Effect of Using Electric Current during Dentin Bonding Agent Application on Microleakage under Simulated Pulpal Pressure Condition |
title_full_unstemmed | Effect of Using Electric Current during Dentin Bonding Agent Application on Microleakage under Simulated Pulpal Pressure Condition |
title_short | Effect of Using Electric Current during Dentin Bonding Agent Application on Microleakage under Simulated Pulpal Pressure Condition |
title_sort | effect of using electric current during dentin bonding agent application on microleakage under simulated pulpal pressure condition |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3065336/ https://www.ncbi.nlm.nih.gov/pubmed/21448443 |
work_keys_str_mv | AT gharizadehnaghmeh effectofusingelectriccurrentduringdentinbondingagentapplicationonmicroleakageundersimulatedpulpalpressurecondition AT kavianiazita effectofusingelectriccurrentduringdentinbondingagentapplicationonmicroleakageundersimulatedpulpalpressurecondition AT niksamaneh effectofusingelectriccurrentduringdentinbondingagentapplicationonmicroleakageundersimulatedpulpalpressurecondition |