Cargando…

Effect of Using Electric Current during Dentin Bonding Agent Application on Microleakage under Simulated Pulpal Pressure Condition

BACKGROUND: The use of electric current during application of etch-and-rinse adhesive systems has been recently introduced to decrease microleakage. This study investigated the effects of an electric field produced by an experimental device for the application of a two-step etch-and-rinse adhesive o...

Descripción completa

Detalles Bibliográficos
Autores principales: Gharizadeh, Naghmeh, Kaviani, Azita, Nik, Samaneh
Formato: Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3065336/
https://www.ncbi.nlm.nih.gov/pubmed/21448443
_version_ 1782200968031502336
author Gharizadeh, Naghmeh
Kaviani, Azita
Nik, Samaneh
author_facet Gharizadeh, Naghmeh
Kaviani, Azita
Nik, Samaneh
author_sort Gharizadeh, Naghmeh
collection PubMed
description BACKGROUND: The use of electric current during application of etch-and-rinse adhesive systems has been recently introduced to decrease microleakage. This study investigated the effects of an electric field produced by an experimental device for the application of a two-step etch-and-rinse adhesive on moist dentin surface. METHODS: Sixty freshly extracted human premolars were used for this study. In order to simulate real conditions, the pulpal pressure was set to 35 cm H(2)O for all the specimens. The teeth were divided into two groups: in group I, etch-and-rinse system (Single Bond) was applied with electric current while group II, etch-and-rinse system (Single Bond) was applied without electric current. Specimens were prepared for dye penetration test. The data were analyzed using Mann-Whitney U test. RESULTS: The results showed that group I had less microleakage scores compared to group II (P = 0.047). CONCLUSION: Based on the result of this study, it could be concluded that using electric current for applying adhesive systems had a significant effect on reducing microleakage.
format Text
id pubmed-3065336
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-30653362011-03-29 Effect of Using Electric Current during Dentin Bonding Agent Application on Microleakage under Simulated Pulpal Pressure Condition Gharizadeh, Naghmeh Kaviani, Azita Nik, Samaneh Dent Res J (Isfahan) Original Article BACKGROUND: The use of electric current during application of etch-and-rinse adhesive systems has been recently introduced to decrease microleakage. This study investigated the effects of an electric field produced by an experimental device for the application of a two-step etch-and-rinse adhesive on moist dentin surface. METHODS: Sixty freshly extracted human premolars were used for this study. In order to simulate real conditions, the pulpal pressure was set to 35 cm H(2)O for all the specimens. The teeth were divided into two groups: in group I, etch-and-rinse system (Single Bond) was applied with electric current while group II, etch-and-rinse system (Single Bond) was applied without electric current. Specimens were prepared for dye penetration test. The data were analyzed using Mann-Whitney U test. RESULTS: The results showed that group I had less microleakage scores compared to group II (P = 0.047). CONCLUSION: Based on the result of this study, it could be concluded that using electric current for applying adhesive systems had a significant effect on reducing microleakage. Medknow Publications & Media Pvt Ltd 2010 /pmc/articles/PMC3065336/ /pubmed/21448443 Text en Copyright: © Dental Research Journal http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Gharizadeh, Naghmeh
Kaviani, Azita
Nik, Samaneh
Effect of Using Electric Current during Dentin Bonding Agent Application on Microleakage under Simulated Pulpal Pressure Condition
title Effect of Using Electric Current during Dentin Bonding Agent Application on Microleakage under Simulated Pulpal Pressure Condition
title_full Effect of Using Electric Current during Dentin Bonding Agent Application on Microleakage under Simulated Pulpal Pressure Condition
title_fullStr Effect of Using Electric Current during Dentin Bonding Agent Application on Microleakage under Simulated Pulpal Pressure Condition
title_full_unstemmed Effect of Using Electric Current during Dentin Bonding Agent Application on Microleakage under Simulated Pulpal Pressure Condition
title_short Effect of Using Electric Current during Dentin Bonding Agent Application on Microleakage under Simulated Pulpal Pressure Condition
title_sort effect of using electric current during dentin bonding agent application on microleakage under simulated pulpal pressure condition
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3065336/
https://www.ncbi.nlm.nih.gov/pubmed/21448443
work_keys_str_mv AT gharizadehnaghmeh effectofusingelectriccurrentduringdentinbondingagentapplicationonmicroleakageundersimulatedpulpalpressurecondition
AT kavianiazita effectofusingelectriccurrentduringdentinbondingagentapplicationonmicroleakageundersimulatedpulpalpressurecondition
AT niksamaneh effectofusingelectriccurrentduringdentinbondingagentapplicationonmicroleakageundersimulatedpulpalpressurecondition